Temporally aware volumetric generative adversarial network‐based MR image reconstruction with simultaneous respiratory motion compensation: Initial feasibility in 3D dynamic cine cardiac MRI
- 13 July 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2666-2683
Abstract
Purpose: Develop a novel three‐dimensional (3D) generative adversarial network (GAN)‐based technique for simultaneous image reconstruction and respiratory motion compensation of 4D MRI. Our goal was to enable high‐acceleration factors 10.7X‐15.8X, while maintaining robust and diagnostic image quality superior to state‐of‐the‐art self‐gating (SG) compressed sensing wavelet (CS‐WV) reconstruction at lower acceleration factors 3.5X‐7.9X.Methods: Our GAN was trained based on pixel‐wise content loss functions, adversarial loss function, and a novel data‐driven temporal aware loss function to maintain anatomical accuracy and temporal coherence. Besides image reconstruction, our network also performs respiratory motion compensation for free‐breathing scans. A novel progressive growing‐based strategy was adapted to make the training process possible for the proposed GAN‐based structure. The proposed method was developed and thoroughly evaluated qualitatively and quantitatively based on 3D cardiac cine data from 42 patients.Results: Our proposed method achieved significantly better scores in general image quality and image artifacts at 10.7X‐15.8X acceleration than the SG CS‐WV approach at 3.5X‐7.9X acceleration (4.53 ± 0.540 vs. 3.13 ± 0.681 for general image quality, 4.12 ± 0.429 vs. 2.97 ± 0.434 for image artifacts, P < .05 for both). No spurious anatomical structures were observed in our images. The proposed method enabled similar cardiac‐function quantification as conventional SG CS‐WV. The proposed method achieved faster central processing unit‐based image reconstruction (6 s/cardiac phase) than the SG CS‐WV (312 s/cardiac phase).Conclusion: The proposed method showed promising potential for high‐resolution (1 mm3) free‐breathing 4D MR data acquisition with simultaneous respiratory motion compensation and fast reconstruction time.Keywords
Funding Information
- Clinical Center (R01HL127153)
This publication has 62 references indexed in Scilit:
- Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRIJournal of Magnetic Resonance Imaging, 2012
- Parallel MR imagingJournal of Magnetic Resonance Imaging, 2012
- Improved least squares MR image reconstruction using estimates of k‐Space data consistencyMagnetic Resonance in Medicine, 2011
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Artifacts and pitfalls in MR imaging of the pelvisJournal of Magnetic Resonance Imaging, 2007
- Cardiac MRI: Recent progress and continued challengesJournal of Magnetic Resonance Imaging, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Calculation of a Subject-Specific Adaptive Motion-Correction Factor for Improved Real-Time Navigator Echo-Gated Magnetic Resonance Coronary AngiographyJournal of Cardiovascular Magnetic Resonance, 1999
- FocusingInternational Journal of Computer Vision, 1988