Vahid Ghodrati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vahid Ghodrati has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Ashley Prosper
Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, United States of America
4 shared publications- Peng Hu
Department of Radiological Sciences David Geffen School of Medicine University of California Los Angeles California USA
4 shared publications Arash Bedayat
Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, United States of America
3 shared publicationsFadil Ali
Cleveland Clinic, Cleveland, Ohio, United States of America
3 shared publicationsJ. Paul Finn
Department of Radiological Sciences David Geffen School of Medicine University of California Los Angeles California USA
3 shared publicationsKim‐Lien Nguyen
Department of Radiological Sciences David Geffen School of Medicine University of California Los Angeles California USA
3 shared publications
Latest Publications
- Open Access
- 26 July 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103732
Accelerating cardiac radial-MRI: Fully polar based technique using compressed sensing and deep learning
- 26 July 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103732
Open AccessAccelerating cardiac radial-MRI: Fully polar based technique using compressed sensing and deep learning
- 5 October 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (2) , 984-998
Automatic segmentation of peripheral arteries and veins in ferumoxytol‐enhanced MR angiography
Purpose: To automate the segmentation of the peripheral arteries and veins in the lower extremities based on ferumoxytol‐enhanced MR angiography (FE‐MRA).Methods: Our automated pipeline has 2 sequential stages. In the first stage, we used a 3D U‐Net with local attention gates, which was trained based on a combination of the Focal Tversky loss with region mutual loss under a deep supervision mechanism to segment the vasculature from the high‐resolution FE‐MRA datasets. In the second stage, we used time‐resolved images to separate the arteries from the veins. Because the ultimate segmentation quality of the arteries and veins relies on the performance of the first stage, we thoroughly evaluated the different aspects of the segmentation network and compared its performance in blood vessel segmentation with currently accepted state‐of‐the‐art networks, including Volumetric‐Net, DeepVesselNet‐FCN, and Uception.Results: We achieved a competitive F1 = 0.8087 and recall = 0.8410 for blood vessel segmentation compared with F1 = (0.7604, 0.7573, 0.7651) and recall = (0.7791, 0.7570, 0.7774) obtained with Volumetric‐Net, DeepVesselNet‐FCN, and Uception. For the artery and vein separation stage, we achieved F1 = (0.8274/0.7863) in the calf region, which is the most challenging region in peripheral arteries and veins segmentation.Conclusion: Our pipeline is capable of fully automatic vessel segmentation based on FE‐MRA without need for human interaction in <4 min. This method improves upon manual segmentation by radiologists, which routinely takes several hours.
- 5 October 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (2) , 984-998
Automatic segmentation of peripheral arteries and veins in ferumoxytol‐enhanced MR angiography
Purpose: To automate the segmentation of the peripheral arteries and veins in the lower extremities based on ferumoxytol‐enhanced MR angiography (FE‐MRA).Methods: Our automated pipeline has 2 sequential stages. In the first stage, we used a 3D U‐Net with local attention gates, which was trained based on a combination of the Focal Tversky loss with region mutual loss under a deep supervision mechanism to segment the vasculature from the high‐resolution FE‐MRA datasets. In the second stage, we used time‐resolved images to separate the arteries from the veins. Because the ultimate segmentation quality of the arteries and veins relies on the performance of the first stage, we thoroughly evaluated the different aspects of the segmentation network and compared its performance in blood vessel segmentation with currently accepted state‐of‐the‐art networks, including Volumetric‐Net, DeepVesselNet‐FCN, and Uception.Results: We achieved a competitive F1 = 0.8087 and recall = 0.8410 for blood vessel segmentation compared with F1 = (0.7604, 0.7573, 0.7651) and recall = (0.7791, 0.7570, 0.7774) obtained with Volumetric‐Net, DeepVesselNet‐FCN, and Uception. For the artery and vein separation stage, we achieved F1 = (0.8274/0.7863) in the calf region, which is the most challenging region in peripheral arteries and veins segmentation.Conclusion: Our pipeline is capable of fully automatic vessel segmentation based on FE‐MRA without need for human interaction in <4 min. This method improves upon manual segmentation by radiologists, which routinely takes several hours.
- 13 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2666-2683
Temporally aware volumetric generative adversarial network‐based MR image reconstruction with simultaneous respiratory motion compensation: Initial feasibility in 3D dynamic cine cardiac MRI
Purpose: Develop a novel three‐dimensional (3D) generative adversarial network (GAN)‐based technique for simultaneous image reconstruction and respiratory motion compensation of 4D MRI. Our goal was to enable high‐acceleration factors 10.7X‐15.8X, while maintaining robust and diagnostic image quality superior to state‐of‐the‐art self‐gating (SG) compressed sensing wavelet (CS‐WV) reconstruction at lower acceleration factors 3.5X‐7.9X.Methods: Our GAN was trained based on pixel‐wise content loss functions, adversarial loss function, and a novel data‐driven temporal aware loss function to maintain anatomical accuracy and temporal coherence. Besides image reconstruction, our network also performs respiratory motion compensation for free‐breathing scans. A novel progressive growing‐based strategy was adapted to make the training process possible for the proposed GAN‐based structure. The proposed method was developed and thoroughly evaluated qualitatively and quantitatively based on 3D cardiac cine data from 42 patients.Results: Our proposed method achieved significantly better scores in general image quality and image artifacts at 10.7X‐15.8X acceleration than the SG CS‐WV approach at 3.5X‐7.9X acceleration (4.53 ± 0.540 vs. 3.13 ± 0.681 for general image quality, 4.12 ± 0.429 vs. 2.97 ± 0.434 for image artifacts, P < .05 for both). No spurious anatomical structures were observed in our images. The proposed method enabled similar cardiac‐function quantification as conventional SG CS‐WV. The proposed method achieved faster central processing unit‐based image reconstruction (6 s/cardiac phase) than the SG CS‐WV (312 s/cardiac phase).Conclusion: The proposed method showed promising potential for high‐resolution (1 mm3) free‐breathing 4D MR data acquisition with simultaneous respiratory motion compensation and fast reconstruction time.
- 13 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2666-2683
Temporally aware volumetric generative adversarial network‐based MR image reconstruction with simultaneous respiratory motion compensation: Initial feasibility in 3D dynamic cine cardiac MRI
Purpose: Develop a novel three‐dimensional (3D) generative adversarial network (GAN)‐based technique for simultaneous image reconstruction and respiratory motion compensation of 4D MRI. Our goal was to enable high‐acceleration factors 10.7X‐15.8X, while maintaining robust and diagnostic image quality superior to state‐of‐the‐art self‐gating (SG) compressed sensing wavelet (CS‐WV) reconstruction at lower acceleration factors 3.5X‐7.9X.Methods: Our GAN was trained based on pixel‐wise content loss functions, adversarial loss function, and a novel data‐driven temporal aware loss function to maintain anatomical accuracy and temporal coherence. Besides image reconstruction, our network also performs respiratory motion compensation for free‐breathing scans. A novel progressive growing‐based strategy was adapted to make the training process possible for the proposed GAN‐based structure. The proposed method was developed and thoroughly evaluated qualitatively and quantitatively based on 3D cardiac cine data from 42 patients.Results: Our proposed method achieved significantly better scores in general image quality and image artifacts at 10.7X‐15.8X acceleration than the SG CS‐WV approach at 3.5X‐7.9X acceleration (4.53 ± 0.540 vs. 3.13 ± 0.681 for general image quality, 4.12 ± 0.429 vs. 2.97 ± 0.434 for image artifacts, P < .05 for both). No spurious anatomical structures were observed in our images. The proposed method enabled similar cardiac‐function quantification as conventional SG CS‐WV. The proposed method achieved faster central processing unit‐based image reconstruction (6 s/cardiac phase) than the SG CS‐WV (312 s/cardiac phase).Conclusion: The proposed method showed promising potential for high‐resolution (1 mm3) free‐breathing 4D MR data acquisition with simultaneous respiratory motion compensation and fast reconstruction time.
- 31 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (4) , 2034-2048
Slice encoding for the reduction of outflow signal artifacts in cine balanced SSFP imaging
Purpose Standard balanced SSFP (bSSFP) cine MRI often suffers from blood outflow artifacts. We propose a method that spatially encodes these outflowing spins to reduce their effects in the intended slice. Methods Bloch simulations were performed to characterize through-plane flow and to investigate how the use of phase encoding along the slice select’s direction (“slice encoding”) could alleviate its issues. Phantom scans and in vivo cines were acquired on a 3T system, comparing the standard 2D acquisition to the proposed slice-encoding method. Nineteen healthy volunteers were recruited for short-axis and horizontal long-axis oriented scans. An expert radiologist evaluated each slice-encoded/standard cine pairs in a rank comparison test and graded their quality on a 1-5 scale. The grades were used for a nonparametric paired evaluation for independent samples with a null hypothesis that there was no statistical difference between the two quality-grade distributions for α = 0.05 significance. Results Bloch simulation results demonstrated this technique’s feasibility, showing a fully resolved slice profile given a sufficient number of slice encodes. These results were confirmed with the phantom experiments. Each in vivo slice-encoded cine had a higher quality than its corresponding standard acquisition. The nonparametric paired evaluation came to 0.01 significance, encouraging us to reject the null hypothesis and conclude that slice-encoding effectively works in reducing outflow effects. Conclusion The slice-encoding balanced SSFP technique is helpful in mitigating outflow effects and is achievable within a single breath hold, being a useful alternative for cases in which the flow artifacts are significant.
- 31 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (4) , 2034-2048
Slice encoding for the reduction of outflow signal artifacts in cine balanced SSFP imaging
Purpose Standard balanced SSFP (bSSFP) cine MRI often suffers from blood outflow artifacts. We propose a method that spatially encodes these outflowing spins to reduce their effects in the intended slice. Methods Bloch simulations were performed to characterize through-plane flow and to investigate how the use of phase encoding along the slice select’s direction (“slice encoding”) could alleviate its issues. Phantom scans and in vivo cines were acquired on a 3T system, comparing the standard 2D acquisition to the proposed slice-encoding method. Nineteen healthy volunteers were recruited for short-axis and horizontal long-axis oriented scans. An expert radiologist evaluated each slice-encoded/standard cine pairs in a rank comparison test and graded their quality on a 1-5 scale. The grades were used for a nonparametric paired evaluation for independent samples with a null hypothesis that there was no statistical difference between the two quality-grade distributions for α = 0.05 significance. Results Bloch simulation results demonstrated this technique’s feasibility, showing a fully resolved slice profile given a sufficient number of slice encodes. These results were confirmed with the phantom experiments. Each in vivo slice-encoded cine had a higher quality than its corresponding standard acquisition. The nonparametric paired evaluation came to 0.01 significance, encouraging us to reject the null hypothesis and conclude that slice-encoding effectively works in reducing outflow effects. Conclusion The slice-encoding balanced SSFP technique is helpful in mitigating outflow effects and is achievable within a single breath hold, being a useful alternative for cases in which the flow artifacts are significant.
- 9 December 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (4) , e4458
Minimizing echo and repetition times in magnetic resonance imaging using a double half‐echo k‐space acquisition and low‐rank reconstruction
Sampling k‐space asymmetrically (ie, partial Fourier sampling) in the readout direction is a common way to reduce the echo time (TE) during magnetic resonance image acquisitions. This technique requires overlap around the center of k‐space to provide a calibration region for reconstruction, which limits the minimum fractional echo to ~60% before artifacts are observed. The present study describes a method for reconstructing images from exact half echoes using two separate acquisitions with reversed readout polarity, effectively providing a full line of k‐space without additional data around central k‐space. This approach can benefit sequences or applications that prioritize short TE, short inter‐echo spacing or short repetition time. An example of the latter is demonstrated to reduce banding artifacts in balanced steady‐state free precession.
- 9 December 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (4) , e4458
Minimizing echo and repetition times in magnetic resonance imaging using a double half‐echo k‐space acquisition and low‐rank reconstruction
Sampling k‐space asymmetrically (ie, partial Fourier sampling) in the readout direction is a common way to reduce the echo time (TE) during magnetic resonance image acquisitions. This technique requires overlap around the center of k‐space to provide a calibration region for reconstruction, which limits the minimum fractional echo to ~60% before artifacts are observed. The present study describes a method for reconstructing images from exact half echoes using two separate acquisitions with reversed readout polarity, effectively providing a full line of k‐space without additional data around central k‐space. This approach can benefit sequences or applications that prioritize short TE, short inter‐echo spacing or short repetition time. An example of the latter is demonstrated to reduce banding artifacts in balanced steady‐state free precession.
- 30 November 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (2) , e4433
Retrospective respiratory motion correction in cardiac cine MRI reconstruction using adversarial autoencoder and unsupervised learning
The aim of this study was to develop a deep neural network for respiratory motion compensation in free‐breathing cine MRI and evaluate its performance. An adversarial autoencoder network was trained using unpaired training data from healthy volunteers and patients who underwent clinically indicated cardiac MRI examinations. A U‐net structure was used for the encoder and decoder parts of the network and the code space was regularized by an adversarial objective. The autoencoder learns the identity map for the free‐breathing motion‐corrupted images and preserves the structural content of the images, while the discriminator, which interacts with the output of the encoder, forces the encoder to remove motion artifacts. The network was first evaluated based on data that were artificially corrupted with simulated rigid motion with regard to motion‐correction accuracy and the presence of any artificially created structures. Subsequently, to demonstrate the feasibility of the proposed approach in vivo, our network was trained on respiratory motion‐corrupted images in an unpaired manner and was tested on volunteer and patient data. In the simulation study, mean structural similarity index scores for the synthesized motion‐corrupted images and motion‐corrected images were 0.76 and 0.93 (out of 1), respectively. The proposed method increased the Tenengrad focus measure of the motion‐corrupted images by 12% in the simulation study and by 7% in the in vivo study. The average overall subjective image quality scores for the motion‐corrupted images, motion‐corrected images and breath‐held images were 2.5, 3.5 and 4.1 (out of 5.0), respectively. Nonparametric‐paired comparisons showed that there was significant difference between the image quality scores of the motion‐corrupted and breath‐held images (P < .05); however, after correction there was no significant difference between the image quality scores of the motion‐corrected and breath‐held images. This feasibility study demonstrates the potential of an adversarial autoencoder network for correcting respiratory motion‐related image artifacts without requiring paired data.
- 30 November 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (2) , e4433
Retrospective respiratory motion correction in cardiac cine MRI reconstruction using adversarial autoencoder and unsupervised learning
The aim of this study was to develop a deep neural network for respiratory motion compensation in free‐breathing cine MRI and evaluate its performance. An adversarial autoencoder network was trained using unpaired training data from healthy volunteers and patients who underwent clinically indicated cardiac MRI examinations. A U‐net structure was used for the encoder and decoder parts of the network and the code space was regularized by an adversarial objective. The autoencoder learns the identity map for the free‐breathing motion‐corrupted images and preserves the structural content of the images, while the discriminator, which interacts with the output of the encoder, forces the encoder to remove motion artifacts. The network was first evaluated based on data that were artificially corrupted with simulated rigid motion with regard to motion‐correction accuracy and the presence of any artificially created structures. Subsequently, to demonstrate the feasibility of the proposed approach in vivo, our network was trained on respiratory motion‐corrupted images in an unpaired manner and was tested on volunteer and patient data. In the simulation study, mean structural similarity index scores for the synthesized motion‐corrupted images and motion‐corrected images were 0.76 and 0.93 (out of 1), respectively. The proposed method increased the Tenengrad focus measure of the motion‐corrupted images by 12% in the simulation study and by 7% in the in vivo study. The average overall subjective image quality scores for the motion‐corrupted images, motion‐corrected images and breath‐held images were 2.5, 3.5 and 4.1 (out of 5.0), respectively. Nonparametric‐paired comparisons showed that there was significant difference between the image quality scores of the motion‐corrupted and breath‐held images (P < .05); however, after correction there was no significant difference between the image quality scores of the motion‐corrected and breath‐held images. This feasibility study demonstrates the potential of an adversarial autoencoder network for correcting respiratory motion‐related image artifacts without requiring paired data.