The use of imageless navigation to quantify cutting error in total knee arthroplasty
Open Access
- 4 December 2021
- journal article
- research article
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 33 (1) , 1-9
Abstract
Purpose: Navigated total knee arthroplasty (TKA) improves implant alignment by providing feedback on resection parameters based on femoral and tibial cutting guide positions. However, saw blade thickness, deflection, and cutting guide motion may lead to final bone cuts differing from planned resections, potentially contributing to suboptimal component alignment. We used an imageless navigation device to intraoperatively quantify the magnitude of error between planned and actual resections, hypothesizing final bone cuts will differ from planned alignment. Materials and methods: A retrospective study including 60 consecutive patients undergoing primary TKA using a novel imageless navigation device was conducted. Device measurements of resection parameters were obtained via attachment of optical trackers to femoral and tibial cutting guides prior to resection. Following resection, optical trackers were placed directly on the bone cut surface and measurements were recorded. Cutting guide and bone resection measurements of both femoral and tibial varus/valgus, femoral flexion, tibial slope angles, and both femoral and tibial medial and lateral resection depths were compared using a Student's t-test. Results: Femoral cutting guide position differed from the actual cut by an average 0.6 ± 0.5° (p = 0.85) in the varus/valgus angle and 1.0 ± 1.0° (p = 0.003) in the flexion/extension angle. The difference between planned and actual cut measurements for medial and lateral femoral resection depth was 1.1 ± 1.1 mm (p = 0.32) and 1.2 ± 1.0 mm (p = 0.067), respectively. Planned cut measurements based on tibial guide position differed from the actual cut by an average of 0.9 ± 0.8° (p = 0.63) in the varus/valgus angle and 1.1 ± 1.0° (p = 0.95) in slope angle. Measurement of medial and lateral tibial resection depth differed by an average of 0.1 ± 1.8 mm (p = 0.78) and 0.2 ± 2.1 mm (p = 0.85), respectively. Conclusions: Significant discrepancies between planned and actual femoral bone resection were demonstrated for flexion/extension angle, likely the result of cutting error. Our data highlights the importance of cut verification postresection to confirm planned resections are achieved, and suggests imageless navigation may be a source of feedback that would allow surgeons to intraoperatively adjust resections to achieve optimal implant alignment.Keywords
This publication has 33 references indexed in Scilit:
- The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesisInternational Orthopaedics, 2013
- Navigated total knee arthroplasty: is it error‐free?Knee Surgery, Sports Traumatology, Arthroscopy, 2013
- Osteoporosis affects component positioning in computer navigation-assisted total knee arthroplastyThe Knee, 2012
- The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 yearsThe Journal of Bone and Joint Surgery. British volume, 2011
- How much tibial resection is required in total knee arthroplasty?International Orthopaedics, 2010
- Seven Cuts to the Perfect Total KneeOrthopedics, 2009
- Computer-assisted Navigation in TKAClinical Orthopaedics and Related Research, 2006
- The effect of valgus/varus malalignment on load distribution in total knee replacementsJournal of Biomechanics, 2005
- Accuracy of intramedullary alignment in total knee replacementJournal of Biomedical Engineering, 1992
- Surgical instrument design for the accurate cutting of bone for implant fixationClinical Materials, 1992