Suture residues are associated with histomorphological changes in failed anterior cruciate ligament hamstring autografts
Open Access
- 1 April 2026
- journal article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (2)
Abstract
Purpose: This study aimed to evaluate histomorphological changes associated with residual foreign material in failed anterior cruciate ligament (ACL) autografts. We hypothesised that retained suture material is associated with histopathological regression phenomena in ligamentous and osseous compartments following ACL reconstruction failure. Methods: In this prospective study, 43 consecutive patients (mean age 29.7 ± 9.0 years; 20.9% female) undergoing revision surgery after failed autologous ACL reconstruction were included and analysed. A total of 76 bone‐graft specimens were obtained by over‐reaming femoral and tibial drill tunnels to retrieve the periarticular tunnel segment. Specimens were processed using Hematoxylin–Eosin, Masson–Goldner and Elastika–van Gieson staining. Morphological alterations related to foreign material were assessed qualitatively and semi‐quantitatively using a four‐point grading system under light microscopy. Evaluations were performed independently by two observers (a pathology professor and a trained investigator), with consensus in case of disagreement. Results: Foreign material residues were identified in 92.6% of specimens. Polarised light microscopy revealed birefringent suture remnants frequently associated with histiocytic inflammatory reactions and multinucleated giant cells. Observed regression phenomena included inflammatory reactions (IR), capillary proliferation (CP), osteonecrosis (ON), fissural splitting (FS) and intraligamentous cyst formation. Severe tissue destruction of the autograft or bony compartment was present in approximately 20% of femoral and tibial samples. Descriptive contingency analysis indicated that regression phenomena predominantly occurred in association with adjacent foreign body reactions, whereas isolated regression changes without detectable foreign material were rare. Conclusion: Residual suture material in failed ACL reconstructions is frequently associated with inflammatory and degenerative histomorphological changes in both tendon graft and bone tunnel compartments. Although causality cannot be established, these findings suggest that foreign body reactions may contribute to local tissue degradation. Further studies are needed to clarify the clinical and biomechanical relevance of these observations. Level of Evidence: N/A.Keywords
This publication has 14 references indexed in Scilit:
- The effect of surgical suture material on osteoclast generation and implant-looseningInternational Journal of Medical Sciences, 2021
- Comparison of four different suture materials in respect to oral wound healing, microbial colonization, tissue reaction and clinical features—randomized clinical studyClinical Oral Investigations, 2019
- Granuloma formation associated with patellar tendon necrosis in response to Ethibond confirmed by histopathological examinationBMJ Case Reports, 2018
- What Is the Mid-term Failure Rate of Revision ACL Reconstruction? A Systematic ReviewClinical Orthopaedics and Related Research, 2017
- Foreign body granulomatous reaction associated with polyethelene ‘Fiberwire®’ suture material used in Achilles tendon repairFoot and Ankle Surgery, 2014
- Descriptive Epidemiology of the Multicenter ACL Revision Study (MARS) CohortThe American Journal of Sports Medicine, 2010
- Foreign body reaction to a bioabsorbable interference screw after anterior cruciate ligament reconstructionBMJ Case Reports, 2009
- Adverse reaction to surgical sutures in thyroid surgeryHead & Neck, 2002
- Biodegradable Implants in Sports Medicine: The Biological BaseArthroscopy, 2000
- Foreign‐Body Reaction to the Bioabsorbable Suretac DeviceArthroscopy, 2000