Endogenous Gas Formation—An In Vitro Study with Relevance to Gas Microemboli during Cardiopulmonary Bypass
Open Access
- 15 September 2012
- journal article
- research article
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 44 (3) , 126-133
Abstract
Gas embolismis an identified problemduring cardiopulmonary bypass (CPB). Our aim was to analyze the potential influence from gas solubility based on simple physical laws, here called endogenous gas embolism. Gas solubility decreases at higher temperature and gas bubbles are presumably formed at CPB warming. An experimental model to measure gas release was designed. Medium (water or blood retrieved from mediastinal drains, 14.6 mL) was incubated and equilibrated with gas (air, 100% oxygen, or 5% carbon dioxide in air) at low temperature (10°C or 23°C). At warming to 37°C, gas release was digitally measured. Also, the effect of fluid motion was evaluated. At warming, the medium became oversaturated with dissolved gas. When fluid motion was applied, gas was released to form bubbles. This was exemplified by a gas release of .45% (.31/.54, medians and quartile range, volume percent, p = .007) and 1.26% (1.14/1.33, p = .003) when blood was warmed from 23°C or 10°C to 37°C, respectively (carbon dioxide 5% in air). Consistent findings were seen for water and with the other types of gas exposure. The theory of endogenous gas embolization was confirmed with gas being released at warming. The endogenous gas formation demonstrated a dynamic pattern with oversaturation and with rapid gas released at fluid motion. The gas release at warming was substantial, in particular when the results were extrapolated to full-scale CPB conditions. The interference from endogenous gas formation should be considered in parallel to external sources of gas microemboli.Keywords
This publication has 11 references indexed in Scilit:
- Monitoring Microemboli During Cardiopulmonary Bypass with the EDAC® QuantifierThe Journal of ExtraCorporeal Technology, 2010
- Detection and Elimination of Microemboli Related to Cardiopulmonary BypassCirculation: Cardiovascular Quality and Outcomes, 2009
- Impact of oxygenator characteristics on its capability to remove gaseous microemboli.2007
- Fat content in pericardial suction blood and the efficacy of spontaneous density separation and surface adsorption in a prototype system for fat reductionThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Intraluminal aortic manipulation by means of intra-aortic filter, cannulation, and external clamp maneuvers evaluated versus dislodged embolic materialThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Bubbles and bypass: an updatePerfusion, 2004
- Regional oxygenation and systemic inflammatory response during cardiopulmonary bypass: Influence of temperature and blood flow variationsJournal of Cardiothoracic and Vascular Anesthesia, 2003
- Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Cooling Gradients and Formation of Gaseous Microemboli With Cardiopulmonary Bypass: An Echocardiographic StudyThe Annals of Thoracic Surgery, 1997
- PHYSICAL FACTORS RELATING TO GAS EMBOLISM IN BLOODThe Journal of Thoracic and Cardiovascular Surgery, 1961