Monitoring Microemboli During Cardiopulmonary Bypass with the EDAC® Quantifier
Authors:
- 15 September 2010
- journal article
- abstracts
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 42 (3) , 212-218
Abstract
Gaseous emboli may be introduced into the bypass circuit both from the surgical field and during perfusionist interventions. While circuits provide good protection against massive air embolism, they do not remove gaseous microemboli (GME) from the bypass circuit. The purpose of this preliminary study is to assess the incidence of GME during bypass surgery and determine if increased GME counts were associated with specific events during bypass surgery. In 30 cases divided between 15 coronary artery bypass grafts and 15 valve repairs, GME were counted and sized at the three locations on the bypass circuit using the EDAC® Quantifier (Luna Innovations, Roanoke, VA). A mean of 45,276 GME were detected after the arterial line filter during these 30 cases, with significantly more detected (p= .04) post filter during valve cases (mean = 72,137 ± 22,113) than coronary artery bypass graft cases (mean = 18,416 ± 7831). GME detected post filter were significantly correlated in time with counts detected in the venous line (p< .001). Specific events associated with high counts included the initiation of cardiopulmonary bypass, heart manipulations, insertion and removal of clamps, and the administration of drugs. Global factors associated with increased counts post filter included higher venous line counts and higher post reservoir/bubble trap counts. The mean number of microemboli detected during bypass surgery was much higher than reported in other studies of emboli incidence, most likely due to the increased sensitivity of the EDAC® Quantifier compared to other detection modalities. The results furthermore suggest the need for further study of the clinical significance of these microemboli and what practices may be used to reduce GME incidence. Increased in vitro testing of the air handling capability of different circuit designs, along with more clinical studies assessing best clinical practices for reducing GME activity, is recommended.Keywords
This publication has 17 references indexed in Scilit:
- Emboli occurrence during coronary artery bypass surgery: the influence of a new method of perfusionist blood samplingPerfusion, 2008
- Arterial Line Filters Ranked for Gaseous Micro-Emboli Separation Performance: An In Vitro StudyThe Journal of ExtraCorporeal Technology, 2008
- Microemboli detection on extracorporeal bypass circuitsaPerfusion, 2008
- Gaseous Microemboli Sizing in Extracorporeal Circuits Using Ultrasound BackscatterUltrasound in Medicine & Biology, 2007
- The Effectiveness of Low-Prime Cardiopulmonary Bypass Circuits at Removing Gaseous EmboliThe Journal of ExtraCorporeal Technology, 2004
- Bubbles and bypass: an updatePerfusion, 2004
- Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?The Annals of Thoracic Surgery, 2002
- Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2001
- Ex vivo testing of the Quart® arterial line filterPerfusion, 1999
- Microemboli during coronary artery bypass grafting: Genesis and effect on outcomeThe Journal of Thoracic and Cardiovascular Surgery, 1995