Virtual Neuronavigation for Parcel-guided TMS
Preprint
Abstract
Background: rTMS for depression is partially effective which is likely in part due to the treatment coil positioning being based on scalp-based approaches. Such an approach results in not accounting for individual anatomy and therefore delivering electrical currents to non-optimal brain targets. In a pilot study, we demonstrated that rTMS targeted to parcel 46 (p46) of the HCP atlas led to 100% response in patients who were resistant to the standard TMS. Implementing parcel-guided targeting requires neuronavigation. However, neuronavigation use in clinical practice is limited. Besides added cost, need for individual MRI, leveraging new targeting advances requires expertise in 3D brain reconstruction and processing. Methods: We sought to develop a virtual neuronavigation system in which MRI images are processed on the backend to determine p46 and a corresponding individualized 3D printed scalp headgear is developed. The headgear includes markings for the location corresponding to p46 and other anatomical guides. Headgear development involved an iterative sequence of 3D CAD modeling, printing, and testing to meet the gold standard neuronavigation-guided location. Individual headgear accuracy is then verified by positioning on the intended subject and comparing alignment with the location on the scalp and brain intersecting the neuronavigation beam targeting p46. Reproducibility testing was also performed. Results: Across 16 test subjects on which the final version of the headgear could be tested, individualized headgear was found to be 8.31± 4.93 mm from the neuronavigation-determined scalp location. The corresponding distances on the brain was 7.94± 4.99 mm. Within-subject reproducibility (against centroid formed by 3 measurements) was 1.21 ± 0.84 mm across n= 8 subjects. Conclusion: Individualized headgear targeting presents a viable option for practices to leverage state-of-the-art targeting advances without investing in neuronavigation hardware.Keywords
This publication has 30 references indexed in Scilit:
- Individualized and clinically friendly helmet-type coil positioning method (I-Helmet) for transcranial magnetic stimulationBrain Stimulation, 2022
- Updated scalp heuristics for localizing the dorsolateral prefrontal cortex based on convergent evidence of lesion and brain stimulation studies in depressionBrain Stimulation, 2022
- Variability of EEG electrode positions and their underlying brain regions: visualizing gel artifacts from a simultaneous EEG‐fMRI datasetBrain and Behavior, 2022
- Targeting repetitive transcranial magnetic stimulation in depression: do we really know what we are stimulating and how best to do it?Brain Stimulation, 2021
- Personalized TMS helmets for quick and reliable TMS administration outside of a laboratory settingBrain Stimulation, 2020
- Antidepressant Efficacy of Prolonged Intermittent Theta Burst Stimulation Monotherapy for Recurrent Depression and Comparison of Methods for Coil Positioning: A Randomized, Double-Blind, Sham-Controlled StudyBiological Psychiatry, 2020
- Reliability of targeting methods in TMS for depression: Beam F3 vs. 5.5 cmBrain Stimulation, 2020
- Efficacy of Transcranial Magnetic Stimulation Targets for Depression Is Related to Intrinsic Functional Connectivity with the Subgenual CingulateBiological Psychiatry, 2012
- Transcranial magnetic stimulation and the challenge of coil placement: A comparison of conventional and stereotaxic neuronavigational strategiesHuman Brain Mapping, 2007
- Determination of 10–20 system electrode locations using magnetic resonance image scanning with markersElectroencephalography and Clinical Neurophysiology, 1993