Yu Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Huang has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
- Lucas C. Parra
Department of Biomedical Engineering at the City College of New York
17 shared publications Marom Bikson
Department of Biomedical Engineering, City College of New York - City University of New York, T-403B Steinman Hall, 140th Street and Convent Avenue, NY 10031, New York, UNITED STATES
8 shared publicationsAbhishek Datta
Research and Development, Soterix Medical, Inc, Woodbridge, NJ, United States
7 shared publications- Abhishek Datta
Research and Development, Soterix Medical Inc., Woodbridge, NJ, USA
4 shared publications - Anli Liu
Department of Neurology, NYU Langone Health, New York, NY
4 shared publications Lucas C Parra
Department of Biomedical Engineering, City College of New York - City University of New York, New York, UNITED STATES
4 shared publications
Latest Publications
- 6 November 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (6) , 065010
On the feasibility of temporal interference stimulation of human brains using two arrays of electrodes
Background. Conventional temporal interference stimulation (TI, TIS, or tTIS) leverages two pairs of electrodes to induce an interfering electrical field in the brain. Both computational and experimental studies show that TI can stimulate deep brain regions without significantly affecting shallow areas. While promising, optimization of the locations and dosages on these two pairs of electrodes for maximal focal modulation remains computationally challenging. We are the first to propose two arrays of electrodes instead of two or multiple pairs of electrodes to boost modulation focality. However, the optimization algorithm outputs too many electrodes with overlaps across two frequencies, making it difficult to implement in practice. Objective. Based on recent progress in developing multi-channel TI devices and computational work on TI optimization, here we again advocate two-array TI with feasibility data. Methods & Results. We give a review on major algorithms for TI optimization, and compare these algorithms over 25 individual heads across six brain targets. We show that the latest optimization algorithm for two-pair TI innately works for two-array TI with the fastest speed (under 30 s) and a similar amount of electrodes as in multi-pair TI. At four of the six targets, this fastest algorithm for two-array TI achieves similar or even better focality than TI using up to 16 pairs of electrodes that takes days to optimize. We also show a hardware implementation of two-array TI using 10 electrodes on our 8-channel TI device. We argue that two-pair TI is only preferred for maximal modulation strength or when hardware is limited to only two current sources. We restate the focality-intensity tradeoff but in the context of TI and provide a first voxel-level map (at 4 mm resolution) of achievable focality and modulation strength by TI in the MNI-152 head template. Conclusions. Compared to two-pair or multi-pair TI, we promote two-array TI for its similar performance in focality and lower cost in terms of both optimization time and electrodes needed. We hope this work will pave the way for future adoptions of two-array TI for more focal non-invasive deep brain stimulation.
- 6 November 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (6) , 065010
On the feasibility of temporal interference stimulation of human brains using two arrays of electrodes
Background. Conventional temporal interference stimulation (TI, TIS, or tTIS) leverages two pairs of electrodes to induce an interfering electrical field in the brain. Both computational and experimental studies show that TI can stimulate deep brain regions without significantly affecting shallow areas. While promising, optimization of the locations and dosages on these two pairs of electrodes for maximal focal modulation remains computationally challenging. We are the first to propose two arrays of electrodes instead of two or multiple pairs of electrodes to boost modulation focality. However, the optimization algorithm outputs too many electrodes with overlaps across two frequencies, making it difficult to implement in practice. Objective. Based on recent progress in developing multi-channel TI devices and computational work on TI optimization, here we again advocate two-array TI with feasibility data. Methods & Results. We give a review on major algorithms for TI optimization, and compare these algorithms over 25 individual heads across six brain targets. We show that the latest optimization algorithm for two-pair TI innately works for two-array TI with the fastest speed (under 30 s) and a similar amount of electrodes as in multi-pair TI. At four of the six targets, this fastest algorithm for two-array TI achieves similar or even better focality than TI using up to 16 pairs of electrodes that takes days to optimize. We also show a hardware implementation of two-array TI using 10 electrodes on our 8-channel TI device. We argue that two-pair TI is only preferred for maximal modulation strength or when hardware is limited to only two current sources. We restate the focality-intensity tradeoff but in the context of TI and provide a first voxel-level map (at 4 mm resolution) of achievable focality and modulation strength by TI in the MNI-152 head template. Conclusions. Compared to two-pair or multi-pair TI, we promote two-array TI for its similar performance in focality and lower cost in terms of both optimization time and electrodes needed. We hope this work will pave the way for future adoptions of two-array TI for more focal non-invasive deep brain stimulation.
- Open Access
On the feasibility of temporal interference stimulation of human brains using two arrays of electrodes
Conventional temporal interference stimulation (TI, TIS, or tTIS) leverages two pairs of electrodes to induce an interfering electrical field in the brain. Both computational and experimental studies show that TI can stimulate deep brain regions without significantly affecting shallow areas. While promising, optimization of the locations and dosages on these two pairs of electrodes for maximal focal modulation remains computationally challenging. We are the first to propose two arrays of electrodes instead of two or multiple pairs of electrodes to boost modulation focality. However, the optimization algorithm outputs too many electrodes with overlaps across two frequencies, making it difficult to implement in practice. Based on recent progress in developing multi-channel TI devices and computational work on TI optimization, here we again advocate two-array TI, but with solid software and hardware evidence to show the feasibility. Specifically, we show that the latest optimization algorithm for two-pair TI innately works for two-array TI with the fastest speed (under 30s) among all major algorithms. With a similar amount of electrodes, two-array TI could achieve better focality (3.03 cm) at the hippocampus even than TI using up to 16 pairs of electrodes (3.19 cm) that takes days to optimize. We also show a hardware implementation of two-array TI using 10 electrodes on our 8-channel TI device. We argue that two-pair TI is only preferred when one does not care about modulation focality and promote two-array TI for its advantages in focality and lower cost in terms of both optimization time and electrodes needed. We restate the focality-intensity tradeoff but in the context of TI and provide a first voxel-level map of achievable focality and modulation strength by TI in the MNI-152 head template. We hope this work will pave the way for future adoptions of two-array TI for more focal non-invasive deep brain stimulation.
Open AccessOn the feasibility of temporal interference stimulation of human brains using two arrays of electrodes
Conventional temporal interference stimulation (TI, TIS, or tTIS) leverages two pairs of electrodes to induce an interfering electrical field in the brain. Both computational and experimental studies show that TI can stimulate deep brain regions without significantly affecting shallow areas. While promising, optimization of the locations and dosages on these two pairs of electrodes for maximal focal modulation remains computationally challenging. We are the first to propose two arrays of electrodes instead of two or multiple pairs of electrodes to boost modulation focality. However, the optimization algorithm outputs too many electrodes with overlaps across two frequencies, making it difficult to implement in practice. Based on recent progress in developing multi-channel TI devices and computational work on TI optimization, here we again advocate two-array TI, but with solid software and hardware evidence to show the feasibility. Specifically, we show that the latest optimization algorithm for two-pair TI innately works for two-array TI with the fastest speed (under 30s) among all major algorithms. With a similar amount of electrodes, two-array TI could achieve better focality (3.03 cm) at the hippocampus even than TI using up to 16 pairs of electrodes (3.19 cm) that takes days to optimize. We also show a hardware implementation of two-array TI using 10 electrodes on our 8-channel TI device. We argue that two-pair TI is only preferred when one does not care about modulation focality and promote two-array TI for its advantages in focality and lower cost in terms of both optimization time and electrodes needed. We restate the focality-intensity tradeoff but in the context of TI and provide a first voxel-level map of achievable focality and modulation strength by TI in the MNI-152 head template. We hope this work will pave the way for future adoptions of two-array TI for more focal non-invasive deep brain stimulation.
- Open Access
Virtual Neuronavigation for Parcel-guided TMS
Background: rTMS for depression is partially effective which is likely in part due to the treatment coil positioning being based on scalp-based approaches. Such an approach results in not accounting for individual anatomy and therefore delivering electrical currents to non-optimal brain targets. In a pilot study, we demonstrated that rTMS targeted to parcel 46 (p46) of the HCP atlas led to 100% response in patients who were resistant to the standard TMS. Implementing parcel-guided targeting requires neuronavigation. However, neuronavigation use in clinical practice is limited. Besides added cost, need for individual MRI, leveraging new targeting advances requires expertise in 3D brain reconstruction and processing. Methods: We sought to develop a virtual neuronavigation system in which MRI images are processed on the backend to determine p46 and a corresponding individualized 3D printed scalp headgear is developed. The headgear includes markings for the location corresponding to p46 and other anatomical guides. Headgear development involved an iterative sequence of 3D CAD modeling, printing, and testing to meet the gold standard neuronavigation-guided location. Individual headgear accuracy is then verified by positioning on the intended subject and comparing alignment with the location on the scalp and brain intersecting the neuronavigation beam targeting p46. Reproducibility testing was also performed. Results: Across 16 test subjects on which the final version of the headgear could be tested, individualized headgear was found to be 8.31± 4.93 mm from the neuronavigation-determined scalp location. The corresponding distances on the brain was 7.94± 4.99 mm. Within-subject reproducibility (against centroid formed by 3 measurements) was 1.21 ± 0.84 mm across n= 8 subjects. Conclusion: Individualized headgear targeting presents a viable option for practices to leverage state-of-the-art targeting advances without investing in neuronavigation hardware.
Open AccessVirtual Neuronavigation for Parcel-guided TMS
Background: rTMS for depression is partially effective which is likely in part due to the treatment coil positioning being based on scalp-based approaches. Such an approach results in not accounting for individual anatomy and therefore delivering electrical currents to non-optimal brain targets. In a pilot study, we demonstrated that rTMS targeted to parcel 46 (p46) of the HCP atlas led to 100% response in patients who were resistant to the standard TMS. Implementing parcel-guided targeting requires neuronavigation. However, neuronavigation use in clinical practice is limited. Besides added cost, need for individual MRI, leveraging new targeting advances requires expertise in 3D brain reconstruction and processing. Methods: We sought to develop a virtual neuronavigation system in which MRI images are processed on the backend to determine p46 and a corresponding individualized 3D printed scalp headgear is developed. The headgear includes markings for the location corresponding to p46 and other anatomical guides. Headgear development involved an iterative sequence of 3D CAD modeling, printing, and testing to meet the gold standard neuronavigation-guided location. Individual headgear accuracy is then verified by positioning on the intended subject and comparing alignment with the location on the scalp and brain intersecting the neuronavigation beam targeting p46. Reproducibility testing was also performed. Results: Across 16 test subjects on which the final version of the headgear could be tested, individualized headgear was found to be 8.31± 4.93 mm from the neuronavigation-determined scalp location. The corresponding distances on the brain was 7.94± 4.99 mm. Within-subject reproducibility (against centroid formed by 3 measurements) was 1.21 ± 0.84 mm across n= 8 subjects. Conclusion: Individualized headgear targeting presents a viable option for practices to leverage state-of-the-art targeting advances without investing in neuronavigation hardware.
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (05) , 1-16
Full-head segmentation of MRI with abnormal brain anatomy: model and data release
PurposeOur goal was to develop a deep network for whole-head segmentation, including clinical magnetic resonance imaging (MRI) with abnormal anatomy, and compile the first public benchmark dataset for this purpose. We collected 98 MRIs with volumetric segmentation labels for a diverse set of human subjects, including normal and abnormal anatomy in clinical cases of stroke and disorders of consciousness.ApproachTraining labels were generated by manually correcting initial automated segmentations for skin/scalp, skull, cerebro-spinal fluid, gray matter, white matter, air cavity, and extracephalic air. We developed a “MultiAxial” network consisting of three 2D U-Net that operate independently in sagittal, axial, and coronal planes, which are then combined to produce a single 3D segmentation.ResultsThe MultiAxial network achieved a test-set Dice scores of 0.88±0.04 (median ± interquartile range) on whole-head segmentation, including gray and white matter. This was compared with 0.86±0.04 for Multipriors and 0.79±0.10 for SPM12, two standard tools currently available for this task. The MultiAxial network gains in robustness by avoiding the need for coregistration with an atlas. It performed well in regions with abnormal anatomy and on images that have been de-identified. It enables more accurate and robust current flow modeling when incorporated into ROAST, a widely used modeling toolbox for transcranial electric stimulation.ConclusionsWe are releasing a new state-of-the-art tool for whole-head MRI segmentation in abnormal anatomy, along with the largest volume of labeled clinical head MRIs, including labels for nonbrain structures. Together, the model and data may serve as a benchmark for future efforts.
- 1 September 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (05) , 1-16
Full-head segmentation of MRI with abnormal brain anatomy: model and data release
PurposeOur goal was to develop a deep network for whole-head segmentation, including clinical magnetic resonance imaging (MRI) with abnormal anatomy, and compile the first public benchmark dataset for this purpose. We collected 98 MRIs with volumetric segmentation labels for a diverse set of human subjects, including normal and abnormal anatomy in clinical cases of stroke and disorders of consciousness.ApproachTraining labels were generated by manually correcting initial automated segmentations for skin/scalp, skull, cerebro-spinal fluid, gray matter, white matter, air cavity, and extracephalic air. We developed a “MultiAxial” network consisting of three 2D U-Net that operate independently in sagittal, axial, and coronal planes, which are then combined to produce a single 3D segmentation.ResultsThe MultiAxial network achieved a test-set Dice scores of 0.88±0.04 (median ± interquartile range) on whole-head segmentation, including gray and white matter. This was compared with 0.86±0.04 for Multipriors and 0.79±0.10 for SPM12, two standard tools currently available for this task. The MultiAxial network gains in robustness by avoiding the need for coregistration with an atlas. It performed well in regions with abnormal anatomy and on images that have been de-identified. It enables more accurate and robust current flow modeling when incorporated into ROAST, a widely used modeling toolbox for transcranial electric stimulation.ConclusionsWe are releasing a new state-of-the-art tool for whole-head MRI segmentation in abnormal anatomy, along with the largest volume of labeled clinical head MRIs, including labels for nonbrain structures. Together, the model and data may serve as a benchmark for future efforts.
- Open Access
- 15 July 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (5) , 1373-1388
On the need of individually optimizing temporal interference stimulation of human brains due to inter-individual variability
- 15 July 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (5) , 1373-1388
Open AccessOn the need of individually optimizing temporal interference stimulation of human brains due to inter-individual variability
- 25 June 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- p. e240550
High-performance Open-source AI for Breast Cancer Detection and Localization in MRI
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop and evaluate an open-source deep learning model for detection and localization of breast cancer on MRI. Materials and Methods In this retrospective study, a deep learning model for breast cancer detection and localization was trained on the largest breast MRI dataset to date. Data included all breast MRIs conducted at a tertiary cancer center in the United States between 2002 and 2019. The model was validated on sagittal MRIs from the primary site ( n = 6,615 breasts). Generalizability was assessed by evaluating model performance on axial data from the primary site ( n = 7,058 breasts) and a second clinical site ( n = 1,840 breasts). Results The primary site dataset included 30,672 sagittal MRI examinations (52,598 breasts) from 9,986 female patients (mean [SD] age, 53 [11] years). The model achieved an area under the receiver operating characteristic curve (AUC) of 0.95 for detecting cancer in the primary site. At 90% specificity (5717/6353), model sensitivity was 83% (217/262), which was comparable to historical performance data for radiologists. The model generalized well to axial examinations, achieving an AUC of 0.92 on data from the same clinical site and 0.92 on data from a secondary site. The model accurately located the tumor in 88.5% (232/262) of sagittal images, 92.8% (272/293) of axial images from the primary site, and 87.7% (807/920) of secondary site axial images. Conclusion The model demonstrated state-of-the-art performance on breast cancer detection. Code and weights are openly available to stimulate further development and validation. ©RSNA, 2025
- 25 June 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- p. e240550
High-performance Open-source AI for Breast Cancer Detection and Localization in MRI
“Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop and evaluate an open-source deep learning model for detection and localization of breast cancer on MRI. Materials and Methods In this retrospective study, a deep learning model for breast cancer detection and localization was trained on the largest breast MRI dataset to date. Data included all breast MRIs conducted at a tertiary cancer center in the United States between 2002 and 2019. The model was validated on sagittal MRIs from the primary site ( n = 6,615 breasts). Generalizability was assessed by evaluating model performance on axial data from the primary site ( n = 7,058 breasts) and a second clinical site ( n = 1,840 breasts). Results The primary site dataset included 30,672 sagittal MRI examinations (52,598 breasts) from 9,986 female patients (mean [SD] age, 53 [11] years). The model achieved an area under the receiver operating characteristic curve (AUC) of 0.95 for detecting cancer in the primary site. At 90% specificity (5717/6353), model sensitivity was 83% (217/262), which was comparable to historical performance data for radiologists. The model generalized well to axial examinations, achieving an AUC of 0.92 on data from the same clinical site and 0.92 on data from a secondary site. The model accurately located the tumor in 88.5% (232/262) of sagittal images, 92.8% (272/293) of axial images from the primary site, and 87.7% (807/920) of secondary site axial images. Conclusion The model demonstrated state-of-the-art performance on breast cancer detection. Code and weights are openly available to stimulate further development and validation. ©RSNA, 2025
- Open Access
On the need of individually optimizing temporal interference stimulation of human brains due to inter-individual variability
Introduction: Transcranial temporal interference stimulation (TI, TIS, or tTIS), also known as interferential stimulation (IFS), is able to focally stimulate deep brain regions, provided it is properly optimized. We previously presented an algorithm for optimizing TI using two arrays of electrodes and showed that it can achieve more focal stimulation compared to optimized high-definition transcranial electrical stimulation (HD-TES) and conventional optimized TI using two pairs of electrodes, especially in the deep brain areas such as the hippocampus. However, those modeling studies were only performed on an averaged head (MNI152 template) and three individual heads without exploring inter-individual variability. Existing TI works in the literature mostly utilize a common (possibly optimized) montage of two pairs of electrodes on different individual heads without considering inter-individual variability. Material and method: Here we aim to study the inter-individual variability of optimized TI by applying the same optimization algorithms on N = 25 heads using their individualized head models. Specifically, we compared the focality achieved by different stimulation techniques at six different regions of interest (ROI; right hippocampus, left dorsolateral prefrontal cortex, left motor cortex, right amygdala, right caudate, and left thalamus) under both individually optimized and unoptimized montages. We also conducted numerical sensitivity analysis on the individual optimization and performed phantom recordings to test our models. Results: As expected, there is a variability in focality achieved by TI of up to 1.2 cm at the same ROI across subjects due to inter-individual differences in the head anatomy and tissue conductivity. We show that optimized TI using two arrays of electrodes achieves higher focality than that from optimized HD-TES at the same level of modulation intensity at 5 of the 6 ROIs. Compared to using a common montage either optimized from the MNI152 template or from the literature, individually optimized TI using two pairs of electrodes improves the focality by up to 4.4 cm, and by up to 1.1 cm if using two arrays of electrodes. Focality achieved by the individual optimization is sensitive to random changes and can vary up to 9.3 cm due to the non-lienarity of TI physics. Experimental recordings on a head phantom confirms the drop in TI stimulation strength when using unoptimized montages as predicted by our in silico models. Conclusion: This work demonstrates the need of individually optimizing TI to target deep brain areas, and advocates against using a common head model and montage for TI modeling and experimental studies.
Open AccessOn the need of individually optimizing temporal interference stimulation of human brains due to inter-individual variability
Introduction: Transcranial temporal interference stimulation (TI, TIS, or tTIS), also known as interferential stimulation (IFS), is able to focally stimulate deep brain regions, provided it is properly optimized. We previously presented an algorithm for optimizing TI using two arrays of electrodes and showed that it can achieve more focal stimulation compared to optimized high-definition transcranial electrical stimulation (HD-TES) and conventional optimized TI using two pairs of electrodes, especially in the deep brain areas such as the hippocampus. However, those modeling studies were only performed on an averaged head (MNI152 template) and three individual heads without exploring inter-individual variability. Existing TI works in the literature mostly utilize a common (possibly optimized) montage of two pairs of electrodes on different individual heads without considering inter-individual variability. Material and method: Here we aim to study the inter-individual variability of optimized TI by applying the same optimization algorithms on N = 25 heads using their individualized head models. Specifically, we compared the focality achieved by different stimulation techniques at six different regions of interest (ROI; right hippocampus, left dorsolateral prefrontal cortex, left motor cortex, right amygdala, right caudate, and left thalamus) under both individually optimized and unoptimized montages. We also conducted numerical sensitivity analysis on the individual optimization and performed phantom recordings to test our models. Results: As expected, there is a variability in focality achieved by TI of up to 1.2 cm at the same ROI across subjects due to inter-individual differences in the head anatomy and tissue conductivity. We show that optimized TI using two arrays of electrodes achieves higher focality than that from optimized HD-TES at the same level of modulation intensity at 5 of the 6 ROIs. Compared to using a common montage either optimized from the MNI152 template or from the literature, individually optimized TI using two pairs of electrodes improves the focality by up to 4.4 cm, and by up to 1.1 cm if using two arrays of electrodes. Focality achieved by the individual optimization is sensitive to random changes and can vary up to 9.3 cm due to the non-lienarity of TI physics. Experimental recordings on a head phantom confirms the drop in TI stimulation strength when using unoptimized montages as predicted by our in silico models. Conclusion: This work demonstrates the need of individually optimizing TI to target deep brain areas, and advocates against using a common head model and montage for TI modeling and experimental studies.
- Open Access
- 26 October 2023
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 17, 1239114
Visualizing interferential stimulation of human brains
Introduction: Transcranial electrical stimulation (TES) is limited in focally stimulating deep-brain regions, even with optimized stimulation montages. Recently, interferential stimulation (IFS), also known as transcranial temporal interference stimulation (TI, TIS, or tTIS), has drawn much attention in the TES community as both computational and experimental studies show that IFS can reach deep-brain areas. However, the underlying electrodynamics of IFS is complicated and difficult to visualize. Existing literature only shows static visualization of the interfered electric field induced by IFS. These could result in a simplified understanding that there is always one static focal spot between the two pairs of stimulation electrodes. This static visualization can be frequently found in the IFS literature. Here, we aimed to systematically visualize the entire dynamics of IFS.Methods and results: Following the previous study, the lead field was solved for the MNI-152 head, and optimal montages using either two pairs of electrodes or two arrays of electrodes were found to stimulate a deep-brain region close to the left striatum with the highest possible focality. We then visualized the two stimulating electrical currents injected with similar frequencies. We animated the instant electric field vector at the target and one exemplary off-target location both in 3D space and as a 2D Lissajous curve. We finally visualized the distribution of the interfered electric field and the amplitude modulation envelope at an axial slice going through the target location. These two quantities were visualized in two directions: radial-in and posterior–anterior.Discussion: We hope that with intuitive visualization, this study can contribute as an educational resource to the community’s understanding of IFS as a powerful modality for non-invasive focal deep-brain stimulation.
- 26 October 2023
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 17, 1239114
Open AccessVisualizing interferential stimulation of human brains
Introduction: Transcranial electrical stimulation (TES) is limited in focally stimulating deep-brain regions, even with optimized stimulation montages. Recently, interferential stimulation (IFS), also known as transcranial temporal interference stimulation (TI, TIS, or tTIS), has drawn much attention in the TES community as both computational and experimental studies show that IFS can reach deep-brain areas. However, the underlying electrodynamics of IFS is complicated and difficult to visualize. Existing literature only shows static visualization of the interfered electric field induced by IFS. These could result in a simplified understanding that there is always one static focal spot between the two pairs of stimulation electrodes. This static visualization can be frequently found in the IFS literature. Here, we aimed to systematically visualize the entire dynamics of IFS.Methods and results: Following the previous study, the lead field was solved for the MNI-152 head, and optimal montages using either two pairs of electrodes or two arrays of electrodes were found to stimulate a deep-brain region close to the left striatum with the highest possible focality. We then visualized the two stimulating electrical currents injected with similar frequencies. We animated the instant electric field vector at the target and one exemplary off-target location both in 3D space and as a 2D Lissajous curve. We finally visualized the distribution of the interfered electric field and the amplitude modulation envelope at an axial slice going through the target location. These two quantities were visualized in two directions: radial-in and posterior–anterior.Discussion: We hope that with intuitive visualization, this study can contribute as an educational resource to the community’s understanding of IFS as a powerful modality for non-invasive focal deep-brain stimulation.
- Open Access
- 20 October 2023
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 17, 1239105
Optimized high-definition tDCS in patients with skull defects and skull plates
Introduction: Transcranial direct current stimulation (tDCS) has been shown to benefit patients with brain lesions or traumatic brain injury (TBI). These patients usually have skull defects with different sizes and electrical conductivities. There is very little data in the literature that show how to optimally stimulate these patients with the presence of skull defects.Methods: Here we leveraged high-resolution (1 mm) realistic head models to explore the best montages targeting right beneath the skull defects with different sizes and conductivities. Specifically, open-source software ROAST was used to solve for the lead field on the publicly available MIDA model. Four different skull defects/plates were modeled with the center above the right primary motor cortex: a larger defect (10 cm diameter) modeled as either titanium or acrylic plate, and a smaller defect (2.5 cm diameter) modeled as either acute state filled with cerebrospinal fluid (CSF) or chronic state with scar tissue. Optimized stimulation with maximal intensity was run using ROAST targeting the right primary motor cortex.Results: We show that optimized high-definition montages can achieve an average of 0.3 V/m higher stimulation intensities at the target compared to un-optimized montages (M1-SO or 4×1). Large skull defects with titanium or acrylic plates significantly reduce the stimulation intensity by about 80%, while small defects with acute (CSF) or chronic (scar) tissues significantly increase the stimulation intensity by about 200%. Furthermore, one can use M1-SO to achieve almost the same stimulation strength as the optimized montage if the skull has a large defect with titanium plate, and there is no significant difference in stimulation intensity between 4×1 montage and the optimized montage for small skull defects with scar tissue.Discussion: Based on this work, future modeling studies leveraging individual anatomy of skull defects may help guide tDCS practice on patients with skull defects and skull plates.
- 20 October 2023
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 17, 1239105
Open AccessOptimized high-definition tDCS in patients with skull defects and skull plates
Introduction: Transcranial direct current stimulation (tDCS) has been shown to benefit patients with brain lesions or traumatic brain injury (TBI). These patients usually have skull defects with different sizes and electrical conductivities. There is very little data in the literature that show how to optimally stimulate these patients with the presence of skull defects.Methods: Here we leveraged high-resolution (1 mm) realistic head models to explore the best montages targeting right beneath the skull defects with different sizes and conductivities. Specifically, open-source software ROAST was used to solve for the lead field on the publicly available MIDA model. Four different skull defects/plates were modeled with the center above the right primary motor cortex: a larger defect (10 cm diameter) modeled as either titanium or acrylic plate, and a smaller defect (2.5 cm diameter) modeled as either acute state filled with cerebrospinal fluid (CSF) or chronic state with scar tissue. Optimized stimulation with maximal intensity was run using ROAST targeting the right primary motor cortex.Results: We show that optimized high-definition montages can achieve an average of 0.3 V/m higher stimulation intensities at the target compared to un-optimized montages (M1-SO or 4×1). Large skull defects with titanium or acrylic plates significantly reduce the stimulation intensity by about 80%, while small defects with acute (CSF) or chronic (scar) tissues significantly increase the stimulation intensity by about 200%. Furthermore, one can use M1-SO to achieve almost the same stimulation strength as the optimized montage if the skull has a large defect with titanium plate, and there is no significant difference in stimulation intensity between 4×1 montage and the optimized montage for small skull defects with scar tissue.Discussion: Based on this work, future modeling studies leveraging individual anatomy of skull defects may help guide tDCS practice on patients with skull defects and skull plates.
- Open Access
- 16 July 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (4) , 1002-1010
Applications of open-source software ROAST in clinical studies: A review
- 16 July 2022
- Published by Elsevier in Brain Stimulation
- Vol. 15 (4) , 1002-1010
Open AccessApplications of open-source software ROAST in clinical studies: A review