Reverse Monte Carlo iterative algorithm for quantification of X‐ray fluorescence analysis based on MCNP6 simulation code
Open Access
- 7 April 2020
- journal article
- research article
- Published by Wiley in X-Ray Spectrometry
- Vol. 49 (5) , 587-595
Abstract
Reverse Monte Carlo iterative algorithm has been developed for quantification of energy‐dispersive X‐ray fluorescence analysis in order to calculate the concentrations of the elementary composition in solid substances. The core of the simulation code was the MCNP6 that is a well‐established and widely applied software package in the nuclear research and practice for simulation of nuclear systems or the full process of gamma‐ or X‐ray spectrometry. The reverse Monte Carlo algorithm and the full analytical procedure was tested by quantitative XRF analysis of reference alloy samples. The atomic compositions of the reference samples were determined by reverse Monte Carlo technique and also fundamental parameter method and by spark emission atomic spectroscopy. The agreement between the results of these three analytical methods was found within the standard deviations of the major elements of the samples. The total duration of the reverse Monte Carlo numerical computation was minimized to a few minutes using the variance reduction procedures available in the MCNP6.Keywords
Funding Information
- National Research, Development and Innovation Found (VKSZ-14-1-2015-0021)
This publication has 18 references indexed in Scilit:
- A novel confocal XRF-Raman spectrometer and FPM model for analysis of solid objects and liquid substancesJournal of Analytical Atomic Spectrometry, 2019
- Confocal macro X‐ray fluorescence spectrometer on commercial 3D printerX-Ray Spectrometry, 2017
- FPM model calculation for micro X-ray fluorescence confocal imaging using synchrotron radiationJournal of Analytical Atomic Spectrometry, 2016
- Development of a new confocal 3D-XRF instrument with an X-ray tubeJournal of Analytical Atomic Spectrometry, 2010
- A compact 3D micro X-ray fluorescence spectrometer with X-ray tube excitation for archaeometric applicationsJournal of Analytical Atomic Spectrometry, 2010
- Development of a transportable µ‐XRF spectrometer with polycapillary half lensX-Ray Spectrometry, 2009
- Characterization and applications of a new tabletop confocal micro X-ray fluorescence setupNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2008
- Quantitative characterization of individual aerosol particles by thin-window electron probe microanalysis combined with iterative simulationSpectrochimica Acta Part B: Atomic Spectroscopy, 2000
- Structural modelling of glasses using reverse Monte Carlo simulationNature, 1990
- Reverse Monte Carlo Simulation: A New Technique for the Determination of Disordered StructuresMolecular Simulation, 1988