AGAnita Gerényi

Anita Gerényi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anita Gerényi has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reverse Monte Carlo iterative algorithm for quantification of X‐ray fluorescence analysis based on MCNP6 simulation code

    by Imre Szalóki, Anita Gerényi, Gábor Radócz

    Reverse Monte Carlo iterative algorithm has been developed for quantification of energy‐dispersive X‐ray fluorescence analysis in order to calculate the concentrations of the elementary composition in solid substances. The core of the simulation code was the MCNP6 that is a well‐established and widely applied software package in the nuclear research and practice for simulation of nuclear systems or the full process of gamma‐ or X‐ray spectrometry. The reverse Monte Carlo algorithm and the full analytical procedure was tested by quantitative XRF analysis of reference alloy samples. The atomic compositions of the reference samples were determined by reverse Monte Carlo technique and also fundamental parameter method and by spark emission atomic spectroscopy. The agreement between the results of these three analytical methods was found within the standard deviations of the major elements of the samples. The total duration of the reverse Monte Carlo numerical computation was minimized to a few minutes using the variance reduction procedures available in the MCNP6.


  • Open Access

    A novel confocal XRF-Raman spectrometer and FPM model for analysis of solid objects and liquid substances

    by I Szalóki, T Pintér, I Szalóki, G Radócz, A Gerényi

    A new table-top combined spectrometer was designed and constructed consisting of X-ray fluorescence and Raman spectrometers for spot-analysis of elementary and chemical composition of solid and liquid substances for industrial analytical applications. For XRF analysis a silicon drift detector and an air-cooled low-power transmission type X-ray tube were built in the combined XRF-Raman spectrometer. Both spectrometer units were connected hermetically to a sealed radiation chamber that can be optionally evacuated or it can be filled with helium under atmospheric pressure in order to improve the analytical sensitivity in the region of low-atomic numbers. The XRF and the Raman devices operate in a confocal geometrical arrangement, where the three axes of the Raman laser beam, the exciter X-ray beam, and the X-ray detection channel focus on the same spot of the examined object. The confocal spot of the combined spectrometer can be positioned along the vertical axis with an optional selected step-size of over 0.2 mm. For the precise geometrical adjustment of the focal spot on the sample surface an optical positioning system was designed and built into the irradiation chamber consisting of a mini camera and two mini laser modules. A new FPM model, its algorithm of numerical solution and software were developed for quantitative XRF analysis. The FPM model is based on application of a series of virtual monochromatic X-ray sources used for excitation of the sample elements substituting the experimentally determined spectra of the X-ray tube. The numerical FPM calculations were performed in a matrix-oriented MATLAB programming environment by using self-made software. The model uses both K- and L-lines for the improvement of the accuracy of the calculations and to extend the range of the atomic number of the analysed chemical elements. This FPM model is suitable for the calculation of the concentrations of chemical elements in 4–5 orders of magnitude for liquid and solid materials. In order to maximise the analytical information simultaneous analyses of the Cu content were performed by Raman and XRF spectrometry in an aqueous solution of CuSO4 and citric acid. This experiment proved the synergy of the combined use of these two analytical methods, since both molecular and atomic composition could be analysed quantitatively in the same liquid sample.


  • Confocal macro X‐ray fluorescence spectrometer on commercial 3D printer

    by I. Szalóki, A. Gerényi, G. Radócz

    Novel confocal X‐ray fluorescence (XRF) spectrometer was designed and constructed for 3D analysis of elementary composition in the surface layer of spatially extended objects having unlimited chemical composition and geometrical shape. The main elements of the XRF device were mounted on a moving frame of a commercial 3D printer. The XRF unit consists of a silicon drift detector and a low‐power transmission‐type X‐ray tube. Both the excitation and secondary X‐ray beams were formed and regulated by simple collimator systems in order to create a macro confocal measuring setup. The spatial accuracy of the mechanical stages of the 3D printer achieved was less than 5 μm at 100‐μm step‐size. The diameter of the focal spot of the confocal measuring arrangement was between 1.5 and 2.0 mm. The alignment of the excitation and secondary X‐ray beams and the selection of the measuring spot on the sample surface were ensured by two laser beams and a digital microscope for visualization of the irradiated spot. The elements of the optical system together with the XRF spectrometer were mounted on the horizontal arm of the 3D printer, which mechanical design is capable of synchronized moving the full spectroscopic device within vertical directions. Analytical capability and the 3D spatial resolution of the confocal spectrometer were determined. Copyright © 2017 John Wiley & Sons, Ltd.