Comparing Pre- and Post-operative Fontan Hemodynamic Simulations: Implications for the Reliability of Surgical Planning
- 10 July 2012
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 40 (12) , 2639-2651
Abstract
Virtual modeling of cardiothoracic surgery is a new paradigm that allows for systematic exploration of various operative strategies and uses engineering principles to predict the optimal patient-specific plan. This study investigates the predictive accuracy of such methods for the surgical palliation of single ventricle heart defects. Computational fluid dynamics (CFD)-based surgical planning was used to model the Fontan procedure for four patients prior to surgery. The objective for each was to identify the operative strategy that best distributed hepatic blood flow to the pulmonary arteries. Post-operative magnetic resonance data were acquired to compare (via CFD) the post-operative hemodynamics with predictions. Despite variations in physiologic boundary conditions (e.g., cardiac output, venous flows) and the exact geometry of the surgical baffle, sufficient agreement was observed with respect to hepatic flow distribution (90% confidence interval—14 ± 4.3% difference). There was also good agreement of flow-normalized energetic efficiency predictions (19 ± 4.8% error). The hemodynamic outcomes of prospective patient-specific surgical planning of the Fontan procedure are described for the first time with good quantitative comparisons between preoperatively predicted and postoperative simulations. These results demonstrate that surgical planning can be a useful tool for single ventricle cardiothoracic surgery with the ability to deliver significant clinical impact.Keywords
This publication has 32 references indexed in Scilit:
- Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imagingThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Fluid–structure interaction simulations of the Fontan procedure using variable wall propertiesInternational Journal for Numerical Methods in Biomedical Engineering, 2012
- Individualized computer-based surgical planning to address pulmonary arteriovenous malformations in patients with a single ventricle with an interrupted inferior vena cava and azygous continuationThe Journal of Thoracic and Cardiovascular Surgery, 2011
- A Stochastic Collocation Method for Uncertainty Quantification and Propagation in Cardiovascular SimulationsJournal of Biomechanical Engineering, 2011
- Pulmonary hepatic flow distribution in total cavopulmonary connections: Extracardiac versus intracardiacThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Fontan hemodynamics: Importance of pulmonary artery diameterThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Optimum fuzzy filters for phase-contrast magnetic resonance imaging segmentationJournal of Magnetic Resonance Imaging, 2008
- The total cavopulmonary connection resistance: a significant impact on single ventricle hemodynamics at rest and exerciseAmerican Journal of Physiology-Heart and Circulatory Physiology, 2008
- Application of an adaptive control grid interpolation technique to morphological vascular reconstructionIEEE Transactions on Biomedical Engineering, 2003
- Rest and exercise hemodynamics after the Fontan procedure.Circulation, 1982