Noise Analysis and Design Methodology of Chopper Amplifiers With Analog DC-Servo Loop for Biopotential Acquisition Applications
Open Access
- 9 October 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 32 (1) , 55-67
Abstract
Biopotential acquisition chopper instrumentation amplifiers require a dc-servo loop (DSL) in order to filter electrode dc offsets. However, the noise performance degradation due to the addition of the DSL is often overlooked despite that it can be very detrimental at the frequencies of interest. This article presents an in-depth noise analysis of biopotential acquisition chopper instrumentation amplifiers with analog DSLs. Analytical expressions that predict the noise of different DSL implementations are found and a design flow to minimize their noise contribution is proposed. The design methodology is demonstrated with example circuits targeting biopotential recording systems. These circuits are implemented using a standard 180 nm CMOS technology, and their performance is verified through postlayout simulations. The findings of this work provide a comprehensive understanding of the noise characteristics of a DSL, its impact on noise performance, and design strategies for noise optimization.Keywords
Funding Information
- Swedish Foundation for Strategic Research (ITM17-0079)
- Region Stockholm (979040)
This publication has 33 references indexed in Scilit:
- A 16-Channel CMOS Chopper-Stabilized Analog Front-End ECoG Acquisition Circuit for a Closed-Loop Epileptic Seizure Control SystemIEEE Transactions on Biomedical Circuits and Systems, 2018
- A 16-Channel Patient-Specific Seizure Onset and Termination Detection SoC With Impedance-Adaptive Transcranial Electrical StimulatorIEEE Journal of Solid-State Circuits, 2015
- An Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia MonitoringIEEE Journal of Solid-State Circuits, 2014
- Measurement and Analysis of Current Noise in Chopper AmplifiersIEEE Journal of Solid-State Circuits, 2013
- Design of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition ApplicationsIEEE Transactions on Biomedical Circuits and Systems, 2012
- A 21 nV/$\surd$Hz Chopper-Stabilized Multi-Path Current-Feedback Instrumentation Amplifier With 2 $\mu$V OffsetIEEE Journal of Solid-State Circuits, 2011
- Dry-Contact and Noncontact Biopotential Electrodes: Methodological ReviewIEEE Reviews in Biomedical Engineering, 2010
- A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition SystemsIEEE Journal of Solid-State Circuits, 2007
- Evaluation of commercially available electrodes and gels for recording of slow EEG potentialsClinical Neurophysiology, 2005
- AC-coupled front-end for biopotential measurementsIEEE Transactions on Biomedical Engineering, 2003