YHYu-Kai Huang

Yu-Kai Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu-Kai Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Real-Time Muscle Fatigue Detection System Based on Multifrequency EIM and sEMG for Effective NMES

    by Alejandro D. Fernandez Schrunder, Yu-Kai Huang, Saul Rodriguez, Ana Rusu

    Neuromuscular electrical stimulation (NMES) is a self-directed home-based therapeutic tool in early rehabilitation for musculoskeletal (MSK) conditions. However, the effectiveness of traditional NMES is fundamentally constrained by muscle fatigue. To address this limitation, this work proposes a detection system, which simultaneously records multi-frequency electrical impedance myography (EIM) and surface electromyography (sEMG) in real time for time-frequency analysis of muscle activation, contraction, and fatigue. To demonstrate the ability to monitor these muscle physiological states, two experiments involving weightless and weighted dynamic contractions of the biceps brachii muscle were performed. Results from these experiments show synchronous changes in sEMG and EIM spectra during contractions, and clear trends in sEMG’s mean power frequency (MPF) and EIM spectra with fatigue progression. Additionally, the configurable 4-channel NMES has been electrically evaluated for clinical use, demonstrating the feasibility of the proposed system for closed-loop stimulation. This work showcases the potential of sEMG and multi-frequency EIM to enhance the effectiveness of NMES for MSK conditions by capturing the behavior of distinct mechanisms of muscle fatigue.


  • Open Access

    A Bioimpedance Spectroscopy Interface for EIM Based on IF-Sampling and Pseudo 2-Path SC Bandpass $\Delta\Sigma$ ADC

    by Alejandro D. Fernandez Schrunder, Yu-Kai Huang, Saul Rodriguez, Ana Rusu

    This paper presents a low-noise bioimpedance (bio-Z) spectroscopy interface for electrical impedance myography (EIM) over the 1 kHz to 2 MHz frequency range. The proposed interface employs a sinusoidal signal generator based on direct-digital-synthesis (DDS) to improve the accuracy of the bio-Z reading, and a quadrature low-intermediate frequency (IF) readout to achieve a good noise-to-power efficiency and the required data throughput to detect muscle contractions. The readout is able to measure baseline and time-varying bio-Z by employing robust and power-efficient low-gain IAs and sixth-order single-bit bandpass (BP) ΔΣ ADCs. The proposed bio-Z spectroscopy interface is implemented in a 180 nm CMOS process, consumes 344.3 - 479.3 μ W, and occupies 5.4 mm 2 area. Measurement results show 0.7 $\rm {m} \Omega/\sqrt{Hz}$ sensitivity at 15.625 kHz, 105.8 dB SNR within 4 Hz bandwidth, and a 146.5 dB figure-of-merit. Additionally, recording of EIM in time and frequency domain during contractions of the bicep brachii muscle demonstrates the potential of the proposed bio-Z interface for wearable EIM systems.


  • Open Access

    An Inductorless 40.5V High-Voltage Generator for Integrated Neuromuscular Electrical Stimulators

    by Yu-Kai Huang, Saul Rodriguez

    Neuromuscular electrical stimulation (NMES) requires voltages exceeding several tens of volts which are typically obtained by using DC-DC boost converters. However, these converters incorporate a large external inductor, which hinders integration and severely restricts the minimum size of the stimulator. This paper presents a charge pump (CP) high-voltage generator particularly designed for NMES applications. The proposed hybrid CP comprises a low-voltage latched CP followed by a high-voltage Dickson CP with boosted pumping clocks. This architecture generates an output voltage of 40.5 V from a 3.3 V supply, enabling the delivery of up to 30 mA stimulation pulses at a maximum frequency of 50 Hz. The circuit is designed in a 180 nm HV CMOS process and occupies a silicon area of 2.7 mm 2 . By eliminating the inductor and requiring only one external storage capacitor, this design has the potential of being used in compact stimulators for wearable medical applications.


  • Open Access

    Noise Analysis and Design Methodology of Chopper Amplifiers With Analog DC-Servo Loop for Biopotential Acquisition Applications

    by Yu-Kai Huang, Saul Rodriguez

    Biopotential acquisition chopper instrumentation amplifiers require a dc-servo loop (DSL) in order to filter electrode dc offsets. However, the noise performance degradation due to the addition of the DSL is often overlooked despite that it can be very detrimental at the frequencies of interest. This article presents an in-depth noise analysis of biopotential acquisition chopper instrumentation amplifiers with analog DSLs. Analytical expressions that predict the noise of different DSL implementations are found and a design flow to minimize their noise contribution is proposed. The design methodology is demonstrated with example circuits targeting biopotential recording systems. These circuits are implemented using a standard 180 nm CMOS technology, and their performance is verified through postlayout simulations. The findings of this work provide a comprehensive understanding of the noise characteristics of a DSL, its impact on noise performance, and design strategies for noise optimization.


  • Open Access

    A Current Monitoring and Over-Current Detection Circuit for Safe Electrical Stimulation

    by Yu-Kai Huang, Ana Rusu, Saul Rodriguez

    This brief presents an integrated solution to over-current protection in neuromuscular stimulators. The proposed approach provides fast detection of a single-fault condition, i.e., unintentional electrode short circuit or malfunction of the stimulator, thereby preventing prolonged high-intensity currents from flowing into tissues. In addition, a programmable current threshold enables the system to be also used for monitoring the stimulation intensity. The proposed solution was designed in a 180 nm high-voltage CMOS technology, and its functionality was verified by post-layout simulations in which the safety mechanisms were tested under fault conditions. The implementation only occupies an area of 0.286 mm, making it feasible to be embedded in fully integrated NMES stimulators while providing the required patient safety.


  • Design of a Bone-Guided Cochlear Implant Microsystem With Monopolar Biphasic Multiple Stimulations and Evoked Compound Action Potential Acquisition and Its In Vivo Verification

    by Sung-Hao Wang, Yu-Kai Huang, Ching-Yuan Chen, Li-Yang Tang, Yen-Fu Tu, Po-Chih Chang, Chia-Fone Lee, Chia-Hsiang Yang, Chung-Chih Hung, Chien-Hao Liu, et al.

    A CMOS bone-guided cochlear implant (BGCI) microsystem is proposed and verified. In the implanted System on Chip (SoC) of the proposed BGCI, the evoked compound action potential (ECAP) acquisition and electrode–tissue impedance measurement (EAEIM) circuit is integrated to measure both ECAP and electrode–tissue impedance for clinical diagnoses. Both positive-/negative-voltage charge pumps and monopolar biphasic constant-current stimulation (CCS) stimulator are designed on-chip to realize monopolar biphasic CCS or double-electrode multiple stimulations with a maximum stimulation current of 1.2 mA and a step of 10 $\mu \text{A}$ . With the double-electrode multiple stimulations, the electric field can be shifted and localized under the stimulating electrode to stimulate the auditory nerves. The wireless bilateral data telemetry circuits with a full-wave active rectifier and the pulsed load-shift keying (PLSK) modulators/demodulators are designed for power and data transmission. In vivo animal tests on guinea pigs have shown that the Wave III of electrically evoked auditory brainstem responses (EABRs) can be evoked successfully by electrical stimulation. Moreover, the decreasing latency gradient of evoked Wave III has been measured under the double-electrode multiple stimulations where the location of peak electric field can be shifted to the stimulating electrode in the apical site to stimulate the auditory nerves. Thus, the desired frequency resolution and spatial specificity of stimulation can be achieved. Both electrical measurement and in vivo animal tests have verified that the proposed BGCI microsystem is a feasible solution to eliminate the symptoms for patients with high-frequency hearing loss.