Ultrasound-Based Navigation and 3D CT Compared in Acetabular Cup Position
Authors:
- Olaf HasartOHOlaf Hasart
- Berry M. PoepplauBPBerry M. Poepplau
- Patrick AsbachPAPatrick Asbach
- Carsten PerkaCPCarsten Perka
- Georgi I. WassilewGWGeorgi I. Wassilew
- 1 October 2009
- journal article
- research article
- Published by SLACK, Inc.
- Vol. 32 (10/SUPPLEM) , 6-10
Abstract
Intraoperative landmarks are used in image-free navigation systems. The ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. Our study analyzed the accuracy of ultrasound-based navigation of cup positioning compared with postoperative 3-dimensional (3D) computed tomography scans of cup positioning. Twenty-five ultrasound-navigated total hip arthroplasties (THAs) were analyzed. The difference between the intraoperative cup orientation (navigation) and the postoperative cup position (CT) was evaluated. The average difference between intraoperative navigation and postoperative CT measurements was 2.8 degrees (SD+/-1.8 degrees ) for abduction and 2.2 degrees (SD+/-1.6 degrees ) for anteversion. Therefore, we recommend ultrasound-based navigation as an exact tool for cup positioning in THA.Keywords
This publication has 19 references indexed in Scilit:
- Computer navigation in total hip replacement: a meta-analysisInternational Orthopaedics, 2008
- Computer navigation of the acetabular componentThe Journal of Bone and Joint Surgery. British volume, 2006
- Anatomic Referencing of Cup Orientation in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- Reduced Variability of Acetabular Cup Positioning with Use of an Imageless Navigation SystemClinical Orthopaedics and Related Research, 2004
- Computer-assisted Cup Placement Techniques in Total Hip Arthroplasty Improve Accuracy of PlacementClinical Orthopaedics and Related Research, 2004
- Computer-assisted orthopaedic surgery: minimally invasive hip and knee reconstructionOrthopedic Clinics of North America, 2004
- Comparison of a mechanical acetabular alignment guide with computer placement of the socketThe Journal of Arthroplasty, 2002
- Reduction in Variability of Acetabular Cup Abduction Using Computer Assisted Surgery: A Prospective and Randomized StudyComputer Aided Surgery, 2002
- The effect of acetabular cup orientations on limiting hip rotationThe Journal of Arthroplasty, 1999
- The Influence of Patient-Related Factors and the Position of the Acetabular Component on the Rate of Dislocation after Total Hip Replacement*Journal of Bone and Joint Surgery, 1997