Olaf Hasart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Olaf Hasart has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Carsten Perka
Orthopaedic Department, Center for Musculoskeletal Surgery, Charité, Berlin, Germany
3 shared publications- Carsten Perka
Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, Germany
2 shared publications Georgi I. Wassilew
Orthopaedic Department, Center for Musculoskeletal Surgery, Charité, Berlin, Germany
2 shared publications- Patrick Asbach
Charité - Universitätsmedizin Berlin
2 shared publications Stephan Tohtz
Charité – Universitätsmedizin
2 shared publicationsBerry M. Poepplau
1 shared publication
Latest Publications
- 2 November 2010
- Published by SAGE Publications in Technology and Health Care
- Vol. 18 (4-5) , 341-351
Influence of body mass index and thickness of soft tissue on accuracy of ultrasound and pointer based registration in navigation of cup in hip arthroplasty
Precise identification of bony landmarks by use of pointer based navigation systems is influenced by thickness of soft tissue. Ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. The aim of the study was to investigate the influence of the BMI and the thickness of the soft tissue on the post-operative cup position and accuracy in the application of an ultrasound-based (US CAOS) and a pointer-based navigation system (P CAOS). 82 patients received a hip replacement in minimally invasive surgery in two cohorts: US CAOS group: using ultrasound navigation (n = 39) and P CAOS group: using a pointer-based navigation (n = 43). There was a significant difference in anteversion and anteversion error between the groups. In addition, we observed a significant correlation between the thickness of the presymphysial soft tissue and the anteversion error in both groups. We also detected a significant correlation between the anteversion error and the BMI in both groups. However, the absolute error in anteversion with increasing thickness of the soft tissue layer was slighter in the ultrasound-based group compared to pointer-based navigation. The accuracy of the ultrasound-based and pointer-based navigation systems are influenced by the BMI and the thickness of the soft tissue layer above the symphysis. However, ultrasound-based navigation seems to have advantages with thicker soft tissue layers, as seen in overweight and obese patients.
- 2 November 2010
- Published by SAGE Publications in Technology and Health Care
- Vol. 18 (4-5) , 341-351
Influence of body mass index and thickness of soft tissue on accuracy of ultrasound and pointer based registration in navigation of cup in hip arthroplasty
Precise identification of bony landmarks by use of pointer based navigation systems is influenced by thickness of soft tissue. Ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. The aim of the study was to investigate the influence of the BMI and the thickness of the soft tissue on the post-operative cup position and accuracy in the application of an ultrasound-based (US CAOS) and a pointer-based navigation system (P CAOS). 82 patients received a hip replacement in minimally invasive surgery in two cohorts: US CAOS group: using ultrasound navigation (n = 39) and P CAOS group: using a pointer-based navigation (n = 43). There was a significant difference in anteversion and anteversion error between the groups. In addition, we observed a significant correlation between the thickness of the presymphysial soft tissue and the anteversion error in both groups. We also detected a significant correlation between the anteversion error and the BMI in both groups. However, the absolute error in anteversion with increasing thickness of the soft tissue layer was slighter in the ultrasound-based group compared to pointer-based navigation. The accuracy of the ultrasound-based and pointer-based navigation systems are influenced by the BMI and the thickness of the soft tissue layer above the symphysis. However, ultrasound-based navigation seems to have advantages with thicker soft tissue layers, as seen in overweight and obese patients.
- 31 July 2010
- Published by Springer Nature in Operative Orthopädie und Traumatologie
- Vol. 22 (3) , 268-277
Rekonstruktion größerer Pfannendefekte mit metallischen Augmentaten – Trabecular Metal Technology
Pfannenwechsel mit Wiederherstellung des originären Rotationszentrums. Wiederherstellung einer schmerzfreien Gelenkfunktion. Hohe Primär- sowie Sekundärstabilität. Vermeidung von zusätzlichem Knochenverlust. Knöcherne Defekte des Azetabulums im ventrokranialen, kranialen oder dorsokranialen Areal. Größere kavitäre, zentrale oder ovale Defekte (Paprosky IIb–IIIb). Segmentale Defekte (ventral bis etwa die Hälfte der Gesamtzirkumferenz, dorsal bis etwa ein Drittel der Gesamtzirkumferenz). Manifeste Gelenkinfektion. Beckendiskontinuität (Paprosky IV). Darstellung des Azetabulums und Detektion der Defekt-situation, sorgfältige Säuberung des ossären Lagers von Granulationsgewebe, ggf. Anfrischung des Knochens. Einpassen der metallischen Probeaugmentate. Ziel ist die Defektverkleinerung bzw. das Erreichen eines hemisphärischen Defekts (bei ovalen oder kavitären Defektsituationen) oder eines sog. „contained“ Defekts (bei segmentalen Schäden). Danach Einpassen der Probepfanne. Bei ausreichender Defektfüllung und Stabilität folgen die Einpassung des definitiven Augmentats in den Defekt und die Fixierung mit zwei oder drei Schrauben. Diese werden in die krafttragende Richtung platziert. Zusätzlich besteht die Möglichkeit der ergänzenden Anlagerung von Spongiosachips in den Arealen der Augmentate und/oder des ossären Azetabulums. Versiegelung der kaudalen Oberfläche des Augmentats (Kontaktareal zur Pfanne) mit Knochenzement sowie anschließendes Einschlagen und Verschrauben der Pressfit-Pfanne. Bei stabiler Rekonstruktion der azetabulären und femoralen Defekte ist eine Vollbelastung möglich. Bei sehr ausgedehnten ossären Defekten oder einer pelvitrochantären Insuffizienz wird eine Teilbelastung mit 20 kp für 6 Wochen empfohlen. Eine Anschlussheilbehandlung ist in fast allen Fällen möglich. Von 2005 bis 2007 erfolgte bei 38 Patienten mit Pfannendefektsituationen Typ IIIa und IIIb nach Paprosky die Rekonstruktion mit dem TMT-System (Trabecular Metal Technology). Nach 25 Monaten war bei allen Patienten eine signifikante Verbesserung der Funktion zu beobachten. Der Merle-d’Aubigné-Score stieg von 6 auf 13 Punkte, der Harris-Hip-Score von 29 auf 78 Punkte. Zwei Revisionen waren wegen Migration bzw. Frühlockerung des Implantats notwendig. Revision of cup and reconstruction of original center of rotation. High primary and secondary stability. Prevention of additional bone loss. Osseous defects at the anterior-cranial, cranial and posterior-cranial rim of acetabulum. Larger cavitary, medial or oval defects (Paprosky IIb–IIIb). Segmental defects (anterior column up to half of host bone, posterior column up to one third of host bone). Infection of total hip arthroplasty. Pelvic discontinuity (Paprosky IV). Exposure of acetabulum and detection of defects. Complete removal of soft tissue from acetabulum, reaming of sclerotic bone, if necessary. Adaptation of trial augments to close an oval defect to a round defect and to reach an uncontained defect, respectively. Adaptation of trial cup. In case of sufficient stability, fixation of final augment with two or three screws in cranial bone stock. The screws should be directed to iliosacral joint. Augmentation with allogenic bone chips is possible in the region of wedge and acetabulum as well. Sealing of rough augment surface with bone cement. Implantation of cup, fixation with screws. Application of insert. Depending on bone defects, full weight bearing is possible. In cases of severe bone defects, reduction of weight bearing to 20 kg for 6 weeks is recommended. Postoperative physiotherapy is possible in most cases. Between 2005 and 2007, 38 patients with acetabular defects type IIIa und IIIb according to Paprosky underwent reconstruction using the TMT system (Trabecular Metal Technology). After 25 months, a significant functional improvement was seen in all patients. The Merle d’Aubigné Score increased from 6 points preoperatively to 13 points postoperatively, the Harris Hip Score from 29 to 78 points. Two revisions were necessary because of loosening or migration of the cup.
- 31 July 2010
- Published by Springer Nature in Operative Orthopädie und Traumatologie
- Vol. 22 (3) , 268-277
Rekonstruktion größerer Pfannendefekte mit metallischen Augmentaten – Trabecular Metal Technology
Pfannenwechsel mit Wiederherstellung des originären Rotationszentrums. Wiederherstellung einer schmerzfreien Gelenkfunktion. Hohe Primär- sowie Sekundärstabilität. Vermeidung von zusätzlichem Knochenverlust. Knöcherne Defekte des Azetabulums im ventrokranialen, kranialen oder dorsokranialen Areal. Größere kavitäre, zentrale oder ovale Defekte (Paprosky IIb–IIIb). Segmentale Defekte (ventral bis etwa die Hälfte der Gesamtzirkumferenz, dorsal bis etwa ein Drittel der Gesamtzirkumferenz). Manifeste Gelenkinfektion. Beckendiskontinuität (Paprosky IV). Darstellung des Azetabulums und Detektion der Defekt-situation, sorgfältige Säuberung des ossären Lagers von Granulationsgewebe, ggf. Anfrischung des Knochens. Einpassen der metallischen Probeaugmentate. Ziel ist die Defektverkleinerung bzw. das Erreichen eines hemisphärischen Defekts (bei ovalen oder kavitären Defektsituationen) oder eines sog. „contained“ Defekts (bei segmentalen Schäden). Danach Einpassen der Probepfanne. Bei ausreichender Defektfüllung und Stabilität folgen die Einpassung des definitiven Augmentats in den Defekt und die Fixierung mit zwei oder drei Schrauben. Diese werden in die krafttragende Richtung platziert. Zusätzlich besteht die Möglichkeit der ergänzenden Anlagerung von Spongiosachips in den Arealen der Augmentate und/oder des ossären Azetabulums. Versiegelung der kaudalen Oberfläche des Augmentats (Kontaktareal zur Pfanne) mit Knochenzement sowie anschließendes Einschlagen und Verschrauben der Pressfit-Pfanne. Bei stabiler Rekonstruktion der azetabulären und femoralen Defekte ist eine Vollbelastung möglich. Bei sehr ausgedehnten ossären Defekten oder einer pelvitrochantären Insuffizienz wird eine Teilbelastung mit 20 kp für 6 Wochen empfohlen. Eine Anschlussheilbehandlung ist in fast allen Fällen möglich. Von 2005 bis 2007 erfolgte bei 38 Patienten mit Pfannendefektsituationen Typ IIIa und IIIb nach Paprosky die Rekonstruktion mit dem TMT-System (Trabecular Metal Technology). Nach 25 Monaten war bei allen Patienten eine signifikante Verbesserung der Funktion zu beobachten. Der Merle-d’Aubigné-Score stieg von 6 auf 13 Punkte, der Harris-Hip-Score von 29 auf 78 Punkte. Zwei Revisionen waren wegen Migration bzw. Frühlockerung des Implantats notwendig. Revision of cup and reconstruction of original center of rotation. High primary and secondary stability. Prevention of additional bone loss. Osseous defects at the anterior-cranial, cranial and posterior-cranial rim of acetabulum. Larger cavitary, medial or oval defects (Paprosky IIb–IIIb). Segmental defects (anterior column up to half of host bone, posterior column up to one third of host bone). Infection of total hip arthroplasty. Pelvic discontinuity (Paprosky IV). Exposure of acetabulum and detection of defects. Complete removal of soft tissue from acetabulum, reaming of sclerotic bone, if necessary. Adaptation of trial augments to close an oval defect to a round defect and to reach an uncontained defect, respectively. Adaptation of trial cup. In case of sufficient stability, fixation of final augment with two or three screws in cranial bone stock. The screws should be directed to iliosacral joint. Augmentation with allogenic bone chips is possible in the region of wedge and acetabulum as well. Sealing of rough augment surface with bone cement. Implantation of cup, fixation with screws. Application of insert. Depending on bone defects, full weight bearing is possible. In cases of severe bone defects, reduction of weight bearing to 20 kg for 6 weeks is recommended. Postoperative physiotherapy is possible in most cases. Between 2005 and 2007, 38 patients with acetabular defects type IIIa und IIIb according to Paprosky underwent reconstruction using the TMT system (Trabecular Metal Technology). After 25 months, a significant functional improvement was seen in all patients. The Merle d’Aubigné Score increased from 6 points preoperatively to 13 points postoperatively, the Harris Hip Score from 29 to 78 points. Two revisions were necessary because of loosening or migration of the cup.
- 1 October 2009
- Published by SLACK, Inc.
- Vol. 32 (10/SUPPLEM) , 6-10
Ultrasound-Based Navigation and 3D CT Compared in Acetabular Cup Position
Intraoperative landmarks are used in image-free navigation systems. The ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. Our study analyzed the accuracy of ultrasound-based navigation of cup positioning compared with postoperative 3-dimensional (3D) computed tomography scans of cup positioning. Twenty-five ultrasound-navigated total hip arthroplasties (THAs) were analyzed. The difference between the intraoperative cup orientation (navigation) and the postoperative cup position (CT) was evaluated. The average difference between intraoperative navigation and postoperative CT measurements was 2.8 degrees (SD+/-1.8 degrees ) for abduction and 2.2 degrees (SD+/-1.6 degrees ) for anteversion. Therefore, we recommend ultrasound-based navigation as an exact tool for cup positioning in THA.
- 1 October 2009
- Published by SLACK, Inc.
- Vol. 32 (10/SUPPLEM) , 6-10
Ultrasound-Based Navigation and 3D CT Compared in Acetabular Cup Position
Intraoperative landmarks are used in image-free navigation systems. The ultrasound-based navigation systems try to overcome the problems of positional deviation associated with soft tissue. Our study analyzed the accuracy of ultrasound-based navigation of cup positioning compared with postoperative 3-dimensional (3D) computed tomography scans of cup positioning. Twenty-five ultrasound-navigated total hip arthroplasties (THAs) were analyzed. The difference between the intraoperative cup orientation (navigation) and the postoperative cup position (CT) was evaluated. The average difference between intraoperative navigation and postoperative CT measurements was 2.8 degrees (SD+/-1.8 degrees ) for abduction and 2.2 degrees (SD+/-1.6 degrees ) for anteversion. Therefore, we recommend ultrasound-based navigation as an exact tool for cup positioning in THA.
- 1 October 2008
- Vol. 31
Comparison between pointer-based and ultrasound-based navigation technique in THA using a minimally invasive approach.
The use of navigation techniques in primary total hip arthroplasty improves the position of endoprosthetic components, especially cup positioning. An intraoperative registration of the anterior pelvic plane is necessary to define the anteversion and inclination angles on the acetabular side. This study compares the accuracy of manual pointer palpation to ultrasound registration in navigation to determine pelvic plane registration in 60 cases of minimally invasive surgical technique. Findings show more accurate postoperative radiographic anteversion with ultrasound navigation, although both manual pointer palpation and ultrasound registration techniques show a very small standard deviation in anteversion, inclination, and leg length difference. In conclusion, we recommend navigation as a very reliable tool for the positioning of implants.
- 1 October 2008
- Vol. 31
Comparison between pointer-based and ultrasound-based navigation technique in THA using a minimally invasive approach.
The use of navigation techniques in primary total hip arthroplasty improves the position of endoprosthetic components, especially cup positioning. An intraoperative registration of the anterior pelvic plane is necessary to define the anteversion and inclination angles on the acetabular side. This study compares the accuracy of manual pointer palpation to ultrasound registration in navigation to determine pelvic plane registration in 60 cases of minimally invasive surgical technique. Findings show more accurate postoperative radiographic anteversion with ultrasound navigation, although both manual pointer palpation and ultrasound registration techniques show a very small standard deviation in anteversion, inclination, and leg length difference. In conclusion, we recommend navigation as a very reliable tool for the positioning of implants.
- Open Access
- 21 July 2008
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 3 (1) , 31
Diagnosis of periprosthetic infection following total hip arthroplasty – evaluation of the diagnostic values of pre- and intraoperative parameters and the associated strategy to preoperatively select patients with a high probability of joint infection
The correct diagnosis of a prosthetic joint infection (PJI) is crucial for adequate surgical treatment. The detection may be a challenge since presentation and preoperative tests are not always obvious and precise. This prospective study was performed to evaluate a variety of pre- and intraoperative investigations. Furthermore a detailed evaluation of concordance of each preoperative diagnosis was performed, together with a final diagnosis to assess the accuracy of the pre-operative assumption of PJI.
- 21 July 2008
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 3 (1) , 31
Open AccessDiagnosis of periprosthetic infection following total hip arthroplasty – evaluation of the diagnostic values of pre- and intraoperative parameters and the associated strategy to preoperatively select patients with a high probability of joint infection
The correct diagnosis of a prosthetic joint infection (PJI) is crucial for adequate surgical treatment. The detection may be a challenge since presentation and preoperative tests are not always obvious and precise. This prospective study was performed to evaluate a variety of pre- and intraoperative investigations. Furthermore a detailed evaluation of concordance of each preoperative diagnosis was performed, together with a final diagnosis to assess the accuracy of the pre-operative assumption of PJI.
- 1 May 2002
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und ihre Grenzgebiete
- Vol. 140 (03) , 323-327
Periprothetische knöcherne Veränderungen 2, 4 und 6 Jahre nach Implantation zementfrei verankerter Zweymüller-Schäfte - eine Querschnittsstudie
Studienziel: Für distal verankerte Femurprothesen wird in Längsschnittstudien ein ausgeprägtes proximales „stress shielding” angegeben. Zur Bestimmung einer weitestgehend altersunabhängigen Beurteilung der knöchernen Integration von zementfreien Zweymüller-Schäften sollten diese nach einigen Jahren kontrolliert werden. Methode: Wir untersuchten in einer Querschnittsstudie 92 Patienten klinisch, radiologisch und osteodensitometrisch 2, 4 und 6 Jahre nach der Implantation eines Zweymüller-Schaftes. Als Kontrollgruppe diente die nicht operierte Gegenseite bzw. die Zone 4 nach Gruen unterhalb der Prothese. Ergebnisse: Unter Zugrundelegung dieser Kontrollparameter konnte für keinen Zeitpunkt eine Reduktion der Knochendichte in den proximalen Anteilen nachgewiesen werden. Medial-proximal (Zone 7) wurde sogar eine Zunahme der Knochendichte nach 2 und 4 Jahren gefunden. Die absoluten Dichtewerte waren prä- und postoperativ proximal dennoch am geringsten. Frauen zeigten 6 Jahre nach der Operation gegenüber der Kontrollgruppe sogar eine Zunahme der summierten periprothetischen Knochendichte um 15 %. Ein Einfluss der Femurform auf das knöcherne Remodeling wurde nicht nachgewiesen. Schlussfolgerung: Die Heranziehung der Schaftform als alleinige Ursache für das knöcherne periprothetische Remodeling ist nicht vollständig. Längsschnittstudien können die alters- und aktivitätsbedingte Reduktion der periprothetischen Knochenmasse nur unzureichend wiedergeben. Andere Faktoren, wie der muskulo-skelettäre Kraftfluss, das Geschlecht und das Alter beeinflussen die Osteointegration von Hüftendoprothesen. Aim: According to the results of longitudinal studies, the use of distally anchored femoral prostheses leads to marked proximal stress shielding. Zweymüller stems should be controlled some years after implantation. Method: In a cross-sectional study, we examined 92 patients clinically, radiologically, and osteodensitometrically 2, 4, and 6 years after implantation in order to assess the osseointegration of Zweymüller shafts as independently as possible of age. The non-operated contralateral limb or Gruen's zone 4 below the prosthesis was used as a control group. Results: At no time did the parameters assessed indicate any reduction in proximal bone density as compared with the control group. Zone 7 (medial-proximal) even showed an increase in bone density after 2 and 4 years. Nevertheless, absolute bone density was lowest proximally both pre- and postoperatively. Six years after implantation women even showed a 15 % increase in summated periprosthetic bone density as compared with the control group. No influence of femoral shape on bony remodeling was demonstrated. Conclusion: Periprosthetic bony remodeling cannot be attributed exclusively to the shape of the shaft. Longitudinal studies do not adequately reflect the reduction in periprosthetic bone mass that occurs as a function of age and altered activity level. The osseointegration of hip prostheses is influenced by other factors such as musculoskeletal lines of force, sex, and age.
- 1 May 2002
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und ihre Grenzgebiete
- Vol. 140 (03) , 323-327
Periprothetische knöcherne Veränderungen 2, 4 und 6 Jahre nach Implantation zementfrei verankerter Zweymüller-Schäfte - eine Querschnittsstudie
Studienziel: Für distal verankerte Femurprothesen wird in Längsschnittstudien ein ausgeprägtes proximales „stress shielding” angegeben. Zur Bestimmung einer weitestgehend altersunabhängigen Beurteilung der knöchernen Integration von zementfreien Zweymüller-Schäften sollten diese nach einigen Jahren kontrolliert werden. Methode: Wir untersuchten in einer Querschnittsstudie 92 Patienten klinisch, radiologisch und osteodensitometrisch 2, 4 und 6 Jahre nach der Implantation eines Zweymüller-Schaftes. Als Kontrollgruppe diente die nicht operierte Gegenseite bzw. die Zone 4 nach Gruen unterhalb der Prothese. Ergebnisse: Unter Zugrundelegung dieser Kontrollparameter konnte für keinen Zeitpunkt eine Reduktion der Knochendichte in den proximalen Anteilen nachgewiesen werden. Medial-proximal (Zone 7) wurde sogar eine Zunahme der Knochendichte nach 2 und 4 Jahren gefunden. Die absoluten Dichtewerte waren prä- und postoperativ proximal dennoch am geringsten. Frauen zeigten 6 Jahre nach der Operation gegenüber der Kontrollgruppe sogar eine Zunahme der summierten periprothetischen Knochendichte um 15 %. Ein Einfluss der Femurform auf das knöcherne Remodeling wurde nicht nachgewiesen. Schlussfolgerung: Die Heranziehung der Schaftform als alleinige Ursache für das knöcherne periprothetische Remodeling ist nicht vollständig. Längsschnittstudien können die alters- und aktivitätsbedingte Reduktion der periprothetischen Knochenmasse nur unzureichend wiedergeben. Andere Faktoren, wie der muskulo-skelettäre Kraftfluss, das Geschlecht und das Alter beeinflussen die Osteointegration von Hüftendoprothesen. Aim: According to the results of longitudinal studies, the use of distally anchored femoral prostheses leads to marked proximal stress shielding. Zweymüller stems should be controlled some years after implantation. Method: In a cross-sectional study, we examined 92 patients clinically, radiologically, and osteodensitometrically 2, 4, and 6 years after implantation in order to assess the osseointegration of Zweymüller shafts as independently as possible of age. The non-operated contralateral limb or Gruen's zone 4 below the prosthesis was used as a control group. Results: At no time did the parameters assessed indicate any reduction in proximal bone density as compared with the control group. Zone 7 (medial-proximal) even showed an increase in bone density after 2 and 4 years. Nevertheless, absolute bone density was lowest proximally both pre- and postoperatively. Six years after implantation women even showed a 15 % increase in summated periprosthetic bone density as compared with the control group. No influence of femoral shape on bony remodeling was demonstrated. Conclusion: Periprosthetic bony remodeling cannot be attributed exclusively to the shape of the shaft. Longitudinal studies do not adequately reflect the reduction in periprosthetic bone mass that occurs as a function of age and altered activity level. The osseointegration of hip prostheses is influenced by other factors such as musculoskeletal lines of force, sex, and age.