Application of Allura Red in the construction of a novel amperometric flow sensor for the automatic determination of hydroquinone and catechol using a two-line flow injection manifold with a single-sensor/double-pulse amperometric detection
- 16 January 2019
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (2) , 025801
Abstract
A novel amperometric flow sensor was constructed by the successive voltammetric cycling of a glassy carbon electrode (GCE) in a basic solution of Allura Red. The performance of the constructed treated GCE sensor was characterized in the new flow injection amperometric manifold with a single-sensor/double-pulse amperometric simultaneous detection of hydroquinone (HQ) and catechol (CC). A programmed sequence of two potential steps with magnitudes of +0.18 (at the time of the first sample injection) and +0.26 V (at the time of the second injection) was applied. By designing a proper time delay between a sequence of two sample injections and potential steps, two separate flow injection amperometric peaks were recorded. The first peak corresponds to HQ and the second peak is related to the oxidation of both HQ and CC. The currents obtained from the subtraction of two recorded peaks is utilized to obtain the amount of CC. Under the optimized chemical and instrumental parameters, the relation between the concentration and response of the sensor has a good linearity in the ranges of 0.2–600.0 and 0.2–300.0 µmol l −1 for HQ and CC, respectively. The detection limit obtained for both was 0.15 µmol l −1 (signal-to-noise ratio = 3). The proposed flow sensor was employed for the determination of HQ and CC in the real samples with satisfying precision and accuracy.Keywords
This publication has 44 references indexed in Scilit:
- Simultaneous determination of catechol and hydroquinone by carbon paste electrode modified with hydrophobic ionic liquid-functionalized SBA-15Journal of Solid State Electrochemistry, 2012
- Study on the application of reduced graphene oxide and multiwall carbon nanotubes hybrid materials for simultaneous determination of catechol, hydroquinone, p-cresol and nitriteAnalytica Chimica Acta, 2012
- A Simple Strategy for Simultaneous Determination of Paracetamol and Caffeine Using Flow Injection Analysis with Multiple Pulse Amperometric DetectionElectroanalysis, 2011
- Fast and Accurate Analysis of Drugs Using Amperometry Associated With Flow Injection AnalysisJournal of Pharmaceutical Sciences, 2010
- Simple Flow Injection Analysis System for Simultaneous Determination of Phenolic Antioxidants with Multiple Pulse Amperometric Detection at a Boron-Doped Diamond ElectrodeAnalytical Chemistry, 2010
- Determination of trace heavy metals in herbs by sequential injection analysis-anodic stripping voltammetry using screen-printed carbon nanotubes electrodesAnalytica Chimica Acta, 2010
- Flow‐Injection Amperometric Method for Indirect Determination of Dopamine in the Presence of a Large Excess of Ascorbic AcidElectroanalysis, 2009
- Recent developments in electrochemical flow detections—A reviewAnalytica Chimica Acta, 2009
- On-line stripping voltammetry of trace metals at a flow-through bismuth-film electrode by means of a hybrid flow-injection/sequential-injection systemTalanta, 2007
- Cathodic Electrochemical Detection of Nitrophenols at a Bismuth Film Electrode for Use in Flow AnalysisElectroanalysis, 2004