Ghadamali Bagherian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ghadamali Bagherian has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Mansour Arab Chamjangali
Department of Chemistry, Shahrood University of Technology, Shahrood, Iran
28 shared publications - Nasser Goudarzi
Faculty of Chemistry, Shahrood University of Technology, Shahrood, Iran
10 shared publications Mansour Arab Chamjangali
Faculty of Chemistry, Shahrood University of Technology, Shahrood, Iran
9 shared publicationsMotahare Ashrafi
Faculty of Chemistry, Shahrood University of Technology, Shahrood, Iran
9 shared publicationsNasser Goudarzi
6 shared publicationsFatemeh Mosayebi
College of Chemistry, Shahrood University of Technology, Shahrood, P.O. Box 36155-316, Iran
4 shared publications
Latest Publications
- Open Access
- 12 June 2023
- Published by Springer Nature in SN Applied Sciences
- Vol. 5 (7) , 1-11
On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
This work reports a simple and sensitive on-line solid-phase extraction system for the pre-concentration and determination of a trace amount of Co(II (ions by flame atomic absorption spectrometry (FAAS). This method is based on the on-line retention of cobalt ions with polyvinyl chloride modified by 3-(2-thiazolylazo)-2,6-diaminopyridine in a mini-column system. The retained Co(II) ions were eluted with 1.0 mol L−1 HCl, and direct aspiration to flame atomic absorption spectrometry (FAAS) for an accurate determination of it. The important experimental parameters such as the solution pH, length of column (adsorbent mass), sample flow rate, solvent eluent, type and concentration of the eluent, and co-existing ion effects were investigated in detail and optimized. Under the optimum conditions, the calibration graph was linear over the concentration range of 2–150 µg L−1 for pre-concentration of 10.0 mL of the sample solution. The interassay precession (n = 6) was in the range of 1.8–5.2% at the concentration levels of 10.0, 50.0, 100.0, and 140.0 µg L−1. The limit of detection and enhancement factor were 1.3 µg L−1 and 40, respectively. The method was applied for determination of trace levels of Co(II) ions in different real samples such as tap water, waste water, vegetable, fruit, and drug with satisfactory results.
- 12 June 2023
- Published by Springer Nature in SN Applied Sciences
- Vol. 5 (7) , 1-11
Open AccessOn-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
This work reports a simple and sensitive on-line solid-phase extraction system for the pre-concentration and determination of a trace amount of Co(II (ions by flame atomic absorption spectrometry (FAAS). This method is based on the on-line retention of cobalt ions with polyvinyl chloride modified by 3-(2-thiazolylazo)-2,6-diaminopyridine in a mini-column system. The retained Co(II) ions were eluted with 1.0 mol L−1 HCl, and direct aspiration to flame atomic absorption spectrometry (FAAS) for an accurate determination of it. The important experimental parameters such as the solution pH, length of column (adsorbent mass), sample flow rate, solvent eluent, type and concentration of the eluent, and co-existing ion effects were investigated in detail and optimized. Under the optimum conditions, the calibration graph was linear over the concentration range of 2–150 µg L−1 for pre-concentration of 10.0 mL of the sample solution. The interassay precession (n = 6) was in the range of 1.8–5.2% at the concentration levels of 10.0, 50.0, 100.0, and 140.0 µg L−1. The limit of detection and enhancement factor were 1.3 µg L−1 and 40, respectively. The method was applied for determination of trace levels of Co(II) ions in different real samples such as tap water, waste water, vegetable, fruit, and drug with satisfactory results.
- Open Access
- 3 November 2022
- Published by Springer Nature in Research Square
On-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
This work reports a simple and sensitive on-line solid-phase extraction system for the pre-concentration and determination of a trace amount of Co(II (ions by flame atomic absorption spectrometry (FAAS). This method is based on the on-line retention of cobalt ions with polyvinyl chloride modified by 3-(2-thiazolylazo)-2,6-diaminopyridine (TADAP) in a mini-column system. The retained Co(II) ions were eluted with 1.0 mol L-1 HCl, and direct aspiration to flame atomic absorption spectrometry (FAAS) for an accurate determination of it. The important experimental parameters such as the solution pH, length of column (adsorbent mass), sample flow rate, solvent eluent, type and concentration of the eluent, and co-existing ion effects were investigated in detail and optimized. Under the optimum conditions, the calibration graph was linear over the concentration range of 2-150 µg L-1 for pre-concentration of 10.0 mL of the sample solution. The interassay precession (n = 6) was in the range of 1.8-5.2% at the concentration levels of 10.0, 50.0, 100.0, and 140.0 µg L-1. The limit of detection and enrichment factor were 1.3 µg L-1 and 40, respectively. The method was applied for determination of trace levels of Co(II) ions in different real samples such as tap water, waste water, vegetable, fruit, and drug with satisfactory results.
- 3 November 2022
- Published by Springer Nature in Research Square
Open AccessOn-line determination of the trace amount of cobalt(II) in real samples by flame atomic absorption spectrometry method after pre-concentration by modified polyvinyl chloride
This work reports a simple and sensitive on-line solid-phase extraction system for the pre-concentration and determination of a trace amount of Co(II (ions by flame atomic absorption spectrometry (FAAS). This method is based on the on-line retention of cobalt ions with polyvinyl chloride modified by 3-(2-thiazolylazo)-2,6-diaminopyridine (TADAP) in a mini-column system. The retained Co(II) ions were eluted with 1.0 mol L-1 HCl, and direct aspiration to flame atomic absorption spectrometry (FAAS) for an accurate determination of it. The important experimental parameters such as the solution pH, length of column (adsorbent mass), sample flow rate, solvent eluent, type and concentration of the eluent, and co-existing ion effects were investigated in detail and optimized. Under the optimum conditions, the calibration graph was linear over the concentration range of 2-150 µg L-1 for pre-concentration of 10.0 mL of the sample solution. The interassay precession (n = 6) was in the range of 1.8-5.2% at the concentration levels of 10.0, 50.0, 100.0, and 140.0 µg L-1. The limit of detection and enrichment factor were 1.3 µg L-1 and 40, respectively. The method was applied for determination of trace levels of Co(II) ions in different real samples such as tap water, waste water, vegetable, fruit, and drug with satisfactory results.
- 4 March 2021
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 11 (2) , 198-214
Comparison of Capabilities of Four Spectrophotometric Techniques for Determining Concentrations of Compounds with Highly Severe Overlapping Spectra
In this work, four time-saving, economic, and non-sophisticated spectrophotometric methods are used to determine resorcinol (RES) and catechol (CAT) in their binary solutions. The suggested methods, which require no separation steps, are namely the constant center (CC), ratio difference (RD), H-point standard addition method (HPSAM), and ratio H-point standard addition method (RHPSAM). For each method, the parameters affecting the resolution of the spectra are optimized and used for the quantification of RES and CAT in a blind binary mixture. The results obtained show that out of these four original mathematical techniques, the CC and RD methods have the least errors in the simultaneous determination of RES and CAT in their binary solution with a highly severe overlapping spectra. The calibration curves have a linear behavior over the concentration range of 2.5-20 μg/mL for both substances in both methods. The detection limits for RES are 0.89 μg/mL and 0.355 μg/mL for the CC and RD methods, respectively, and for CAT, they are 0.582 μg/mL and 0.292 μg/mL, respectively. The accuracy and precision of the methods are also investigated. The relative standard deviations have been found to be lower than 6.7 %.
- 4 March 2021
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 11 (2) , 198-214
Comparison of Capabilities of Four Spectrophotometric Techniques for Determining Concentrations of Compounds with Highly Severe Overlapping Spectra
In this work, four time-saving, economic, and non-sophisticated spectrophotometric methods are used to determine resorcinol (RES) and catechol (CAT) in their binary solutions. The suggested methods, which require no separation steps, are namely the constant center (CC), ratio difference (RD), H-point standard addition method (HPSAM), and ratio H-point standard addition method (RHPSAM). For each method, the parameters affecting the resolution of the spectra are optimized and used for the quantification of RES and CAT in a blind binary mixture. The results obtained show that out of these four original mathematical techniques, the CC and RD methods have the least errors in the simultaneous determination of RES and CAT in their binary solution with a highly severe overlapping spectra. The calibration curves have a linear behavior over the concentration range of 2.5-20 μg/mL for both substances in both methods. The detection limits for RES are 0.89 μg/mL and 0.355 μg/mL for the CC and RD methods, respectively, and for CAT, they are 0.582 μg/mL and 0.292 μg/mL, respectively. The accuracy and precision of the methods are also investigated. The relative standard deviations have been found to be lower than 6.7 %.
- 11 February 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (9) , 2369-2379
Removal of lead ions from aqueous solutions using functionalized pine cone powder
- 11 February 2021
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (9) , 2369-2379
Removal of lead ions from aqueous solutions using functionalized pine cone powder
- 6 January 2021
- Published by Taylor & Francis in Polycyclic Aromatic Compounds
- Vol. 42 (6) , 3501-3522
Synthesis and UV-Visible Study of Polyhydroquinolines and 1,4-Dihydropyridines in Magnetized Distilled Water
Magnetized distilled water (MDW), as a green solvent, was used in the Hantzsch four-component synthesis of polyhydroquinolines and the three-component synthesis of 1,4-dihydropyridine condensation reactions of 1,3-cyclohexanedione/dimedone, ethyl acetoacetate/malononitrile, aldehydes, and ammonium acetate under catalyst-free conditions. The developed synthetic technique offers numerous advantages including eco-friendly, simplicity, low-costs, short reaction times, high reaction yields, and easy work-up compared to the traditional synthetic method. Moreover, the reaction rates were followed spectrophotometrically by monitoring the changes in the absorption spectrum of the reaction mixture in ordinary distilled water (ODW) and MDW. Also, the effect of magnetization time and the memory effect were studied.
- 6 January 2021
- Published by Taylor & Francis in Polycyclic Aromatic Compounds
- Vol. 42 (6) , 3501-3522
Synthesis and UV-Visible Study of Polyhydroquinolines and 1,4-Dihydropyridines in Magnetized Distilled Water
Magnetized distilled water (MDW), as a green solvent, was used in the Hantzsch four-component synthesis of polyhydroquinolines and the three-component synthesis of 1,4-dihydropyridine condensation reactions of 1,3-cyclohexanedione/dimedone, ethyl acetoacetate/malononitrile, aldehydes, and ammonium acetate under catalyst-free conditions. The developed synthetic technique offers numerous advantages including eco-friendly, simplicity, low-costs, short reaction times, high reaction yields, and easy work-up compared to the traditional synthetic method. Moreover, the reaction rates were followed spectrophotometrically by monitoring the changes in the absorption spectrum of the reaction mixture in ordinary distilled water (ODW) and MDW. Also, the effect of magnetization time and the memory effect were studied.
- 13 October 2020
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (4) , 839-852
Synthesis of pyrano[2,3‐d]pyrimidines and pyrido[2,3‐d]pyrimidines in the magnetized deionized water based on UV–visible study
- 13 October 2020
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 18 (4) , 839-852
Synthesis of pyrano[2,3‐d]pyrimidines and pyrido[2,3‐d]pyrimidines in the magnetized deionized water based on UV–visible study
- 1 June 2019
- Published by Elsevier in Measurement
- Vol. 139, 454-466
An asymmetric flow injection determination of hydroquinone and catechol: An analytic hierarchy and artificial neural network approach
- 1 June 2019
- Published by Elsevier in Measurement
- Vol. 139, 454-466
An asymmetric flow injection determination of hydroquinone and catechol: An analytic hierarchy and artificial neural network approach
- 24 January 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (2) , 025029
Construction and characterization of GCE/MWCNT/Au-NP as a new impedimetric and voltammetric sensor for determination of gemfibrozil in pharmaceutical and biological samples
A novel electrochemical sensor was constructed for the impedimetric and voltammetric determination of gemfibrozil (GEM) by modification of the glassy carbon electrode (GCE) using multi-walled carbon nanotubes (MWCNTs) and gold nanoparticles (Au-NPs). The inherent properties of MWCNTs such as their high surface area and high conductivity, and the capability of fast electron transfer of Au-NPs were taken into account in constructing the sensor. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and electrochemical impedance spectroscopy (EIS) were used for the characterization of the MWCNTs/Au-NPs modified GCE (GCE/MWCNT/Au-NP) surface. The redox behavior of GEM on the surface of GCE/MWCNT/Au-NP was studied by voltammetric techniques. After optimizing the effective experimental parameters, the sensor’s response toward increasing GEM concentration was studied by square wave voltammetry (SWV) and EIS. The results obtained showed linear responses in the GEM concentration ranges of 0.15–45.0 and 0.10–45.0 μ mol L −1 for SWV and EIS, respectively. The experimental 3 σ detection limits were 0.10 and 0.074 μ mol L −1 for SWV and EIS, respectively. The repeatability of 1.07% and reproducibility of 5% were achieved for five replicate determinations of 15.0 μ mol L −1 of GEM. The sensor efficiency was investigated by its application in the analysis of the real samples pharmaceutical and spiked human serum, and the results obtained were satisfactory.
- 24 January 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (2) , 025029
Construction and characterization of GCE/MWCNT/Au-NP as a new impedimetric and voltammetric sensor for determination of gemfibrozil in pharmaceutical and biological samples
A novel electrochemical sensor was constructed for the impedimetric and voltammetric determination of gemfibrozil (GEM) by modification of the glassy carbon electrode (GCE) using multi-walled carbon nanotubes (MWCNTs) and gold nanoparticles (Au-NPs). The inherent properties of MWCNTs such as their high surface area and high conductivity, and the capability of fast electron transfer of Au-NPs were taken into account in constructing the sensor. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and electrochemical impedance spectroscopy (EIS) were used for the characterization of the MWCNTs/Au-NPs modified GCE (GCE/MWCNT/Au-NP) surface. The redox behavior of GEM on the surface of GCE/MWCNT/Au-NP was studied by voltammetric techniques. After optimizing the effective experimental parameters, the sensor’s response toward increasing GEM concentration was studied by square wave voltammetry (SWV) and EIS. The results obtained showed linear responses in the GEM concentration ranges of 0.15–45.0 and 0.10–45.0 μ mol L −1 for SWV and EIS, respectively. The experimental 3 σ detection limits were 0.10 and 0.074 μ mol L −1 for SWV and EIS, respectively. The repeatability of 1.07% and reproducibility of 5% were achieved for five replicate determinations of 15.0 μ mol L −1 of GEM. The sensor efficiency was investigated by its application in the analysis of the real samples pharmaceutical and spiked human serum, and the results obtained were satisfactory.
- 16 January 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (2) , 025801
Application of Allura Red in the construction of a novel amperometric flow sensor for the automatic determination of hydroquinone and catechol using a two-line flow injection manifold with a single-sensor/double-pulse amperometric detection
A novel amperometric flow sensor was constructed by the successive voltammetric cycling of a glassy carbon electrode (GCE) in a basic solution of Allura Red. The performance of the constructed treated GCE sensor was characterized in the new flow injection amperometric manifold with a single-sensor/double-pulse amperometric simultaneous detection of hydroquinone (HQ) and catechol (CC). A programmed sequence of two potential steps with magnitudes of +0.18 (at the time of the first sample injection) and +0.26 V (at the time of the second injection) was applied. By designing a proper time delay between a sequence of two sample injections and potential steps, two separate flow injection amperometric peaks were recorded. The first peak corresponds to HQ and the second peak is related to the oxidation of both HQ and CC. The currents obtained from the subtraction of two recorded peaks is utilized to obtain the amount of CC. Under the optimized chemical and instrumental parameters, the relation between the concentration and response of the sensor has a good linearity in the ranges of 0.2–600.0 and 0.2–300.0 µmol l −1 for HQ and CC, respectively. The detection limit obtained for both was 0.15 µmol l −1 (signal-to-noise ratio = 3). The proposed flow sensor was employed for the determination of HQ and CC in the real samples with satisfying precision and accuracy.
- 16 January 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (2) , 025801
Application of Allura Red in the construction of a novel amperometric flow sensor for the automatic determination of hydroquinone and catechol using a two-line flow injection manifold with a single-sensor/double-pulse amperometric detection
A novel amperometric flow sensor was constructed by the successive voltammetric cycling of a glassy carbon electrode (GCE) in a basic solution of Allura Red. The performance of the constructed treated GCE sensor was characterized in the new flow injection amperometric manifold with a single-sensor/double-pulse amperometric simultaneous detection of hydroquinone (HQ) and catechol (CC). A programmed sequence of two potential steps with magnitudes of +0.18 (at the time of the first sample injection) and +0.26 V (at the time of the second injection) was applied. By designing a proper time delay between a sequence of two sample injections and potential steps, two separate flow injection amperometric peaks were recorded. The first peak corresponds to HQ and the second peak is related to the oxidation of both HQ and CC. The currents obtained from the subtraction of two recorded peaks is utilized to obtain the amount of CC. Under the optimized chemical and instrumental parameters, the relation between the concentration and response of the sensor has a good linearity in the ranges of 0.2–600.0 and 0.2–300.0 µmol l −1 for HQ and CC, respectively. The detection limit obtained for both was 0.15 µmol l −1 (signal-to-noise ratio = 3). The proposed flow sensor was employed for the determination of HQ and CC in the real samples with satisfying precision and accuracy.