Arterial Pressure Monitoring in Pediatric Patients Undergoing Cardiac Surgery: An Observational Study Comparing Invasive and Non-invasive Measurements
Authors:
- 20 June 2019
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 40 (6) , 1231-1237
Abstract
In pediatric cardiac surgery patients, when an artifact due to overdamping or to underdamping is suspected to affect the invasive arterial blood pressure (IABP) measure and waveform, a check against non-invasive blood pressure (NIBP) could be useful. In this study, we aimed to retrospectively analyze the differences between IABP (single site) and NIBP, measured at four limbs in children admitted to pediatric cardiac intensive care unit. Overall, 51 patients were enrolled for a total of 546 measurements. Average differences between IABP and NIBP measurements were relatively high with 42% of differences laying within the benchmark value of ± 5 mmHg. Differences on the measures on one limb vs. the others for systolic, diastolic, and mean arterial pressures were not significant (p = 0.16, 0.98, and 0.89, respectively). The systolic invasive–non-invasive differences were generally negative and diastolic and mean ones were generally positive. Correlations of clinical variables with arterial pressures at different sites were rather weak: age was associated with increased IABP–NIBP differences, whereas heart rate and vasoactive-inotropic score showed inverse correlation with IABP–NIBP deltas. Average systolic, diastolic, and mean IABP–NIBP differences of 45 patients without underdamping artifacts were not significantly different compared to those of 6 patients with underdamping (p = 0.17, 0.84, and 0.08, respectively). In conclusion, a wide bias can be detected in post-cardiac surgery children between IABP and NIBP pressures in more than half of measurements, with underdamping/resonance incidence being relatively low. Measurement of both methods without a limb preference should be considered in cardiac surgery children.Keywords
This publication has 10 references indexed in Scilit:
- Noninvasive BP Monitoring in the Critically IllChest, 2018
- Risk of over-diagnosis of hypotension in children: a comparative analysis of over 50,000 blood pressure measurementsIntensive Care Medicine, 2017
- The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill childrenCritical Care, 2016
- Blood Pressure Monitoring for the Anesthesiologist: A Practical ReviewAnesthesia & Analgesia, 2016
- Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational studyCritical Care, 2014
- Noninvasive monitoring of blood pressure in the critically illCritical Care Medicine, 2012
- Invasive arterial pressurePediatric Critical Care Medicine, 2012
- Which pressure to believe? A comparison of direct arterial with indirect blood pressure measurement techniques in the pediatric intensive care unitPediatric Critical Care Medicine, 2011
- Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patientsCritical Care Medicine, 2000
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981