Inter-scanner brain MRI volumetric biases persist even in a harmonized multi-subject study of multiple sclerosis
Preprint
Abstract
Background/Purpose: Multicenter study designs involving a variety of MRI scanners have become increasingly common. However, these present the issue of biases in image-based measures due to scanner or site differences. To assess these biases, we imaged 11 volunteers with multiple sclerosis (MS) with scan and rescan data at 4 sites. Materials and Methods: Images were acquired on Siemens or Philips scanners at 3-tesla. Automated white matter lesion detection and whole brain, gray and white matter, and thalamic volumetry were performed, as well as expert manual delineations of T1 and T2 (FLAIR) lesions. Random effect and permutation-based nonparametric modeling was performed to assess differences in estimated volumes within and across sites. Results: Random effect modeling demonstrated model assumption violations for most comparisons of interest. Non-parametric modeling indicated that site explained > 50% of the variation for most estimated volumes. This expanded to > 75% when data from both Siemens and Philips scanners were included. Permutation tests revealed significant differences between average inter- and intra-scanner differences in most estimated brain volumes ( P < .05). The automatic activation of spine coil elements during some acquisitions resulted in a shading artifact in these images. Permutation tests revealed significant differences between thalamic volume measurements from acquisitions with and without this artifact. Conclusion: Differences in brain volumetry persisted across MR scanners despite protocol harmonization. These differences were not well explained by variance component modeling; however, statistical innovations for mitigating inter-scanner differences show promise in reducing biases in multi-center studies of MS.Keywords
This publication has 30 references indexed in Scilit:
- Reliability of neuroanatomical measurements in a multisite longitudinal study of youth at risk for psychosisHuman Brain Mapping, 2013
- Multi-atlas segmentation with joint label fusion and corrective learning—an open source implementationFrontiers in Neuroinformatics, 2013
- A Bayesian model of shape and appearance for subcortical brain segmentationNeuroImage, 2011
- Scan–rescan reliability of subcortical brain volumes derived from automated segmentationHuman Brain Mapping, 2010
- Impact of scanner hardware and imaging protocol on image quality and compartment volume precision in the ADNI cohortNeuroImage, 2010
- Black holes in multiple sclerosis: definition, evolution, and clinical correlationsActa Neurologica Scandinavica, 2009
- MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengthsNeuroImage, 2009
- Effects of acute dehydration on brain morphology in healthy humansHuman Brain Mapping, 2007
- Reliability of brain volumes from multicenter MRI acquisition: A calibration studyHuman Brain Mapping, 2004
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001