Kelly A. Clark
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kelly A. Clark has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Daniel S. Reich
Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke National Institutes of Health Bethesda Maryland USA
3 shared publications- Matthew K. Schindler
Department of Neurology University of Pennsylvania Philadelphia Pennsylvania USA
3 shared publications Anna DuVal
Department of Neurology Johns Hopkins University School of Medicine Baltimore Maryland USA
2 shared publications- Carly M. O'DOnnell
Department of Neurology, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI 53226, USA
2 shared publications Clyde Markowitz
Center for Neuroinflammation and Neurotherapeutics, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publicationsJonathan Zurawski
Department of Neurology, Brigham and Women's Hospital Harvard Medical School Boston Massachusetts USA
2 shared publications
Latest Publications
- 15 October 2024
- Published by Wiley in Journal of Neuroimaging
- Vol. 34 (6) , 750-757
Multicenter validation of automated detection of paramagnetic rim lesions on brain MRI in multiple sclerosis
Background and Purpose: Paramagnetic rim lesions (PRLs) are an MRI biomarker of chronic inflammation in people with multiple sclerosis (MS). PRLs may aid in the diagnosis and prognosis of MS. However, manual identification of PRLs is time‐consuming and prone to poor interrater reliability. To address these challenges, the Automated Paramagnetic Rim Lesion (APRL) algorithm was developed to automate PRL detection. The primary objective of this study is to evaluate the accuracy of APRL for detecting PRLs in a multicenter setting.Methods: We applied APRL to a multicenter dataset, which included 3‐Tesla MRI acquired in 92 participants (43 with MS, 14 with clinically isolated syndrome [CIS]/radiologically isolated syndrome [RIS], 35 without RIS/CIS/MS). Subsequently, we assessed APRL's performance by comparing its results with manual PRL assessments carried out by a team of trained raters.Results: Among the 92 participants, expert raters identified 5637 white matter lesions and 148 PRLs. The automated segmentation method successfully captured 115 (78%) of the manually identified PRLs. Within these 115 identified lesions, APRL differentiated between manually identified PRLs and non‐PRLs with an area under the curve (AUC) of .73 (95% confidence interval [CI]: [.68, .78]). At the subject level, the count of APRL‐identified PRLs predicted MS diagnosis with an AUC of .69 (95% CI: [.57, .81]).Conclusion: Our study demonstrated APRL's capability to differentiate between PRLs and lesions without paramagnetic rims in a multicenter study. Automated identification of PRLs offers greater efficiency over manual identification and could facilitate large‐scale assessments of PRLs in clinical trials.
- 15 October 2024
- Published by Wiley in Journal of Neuroimaging
- Vol. 34 (6) , 750-757
Multicenter validation of automated detection of paramagnetic rim lesions on brain MRI in multiple sclerosis
Background and Purpose: Paramagnetic rim lesions (PRLs) are an MRI biomarker of chronic inflammation in people with multiple sclerosis (MS). PRLs may aid in the diagnosis and prognosis of MS. However, manual identification of PRLs is time‐consuming and prone to poor interrater reliability. To address these challenges, the Automated Paramagnetic Rim Lesion (APRL) algorithm was developed to automate PRL detection. The primary objective of this study is to evaluate the accuracy of APRL for detecting PRLs in a multicenter setting.Methods: We applied APRL to a multicenter dataset, which included 3‐Tesla MRI acquired in 92 participants (43 with MS, 14 with clinically isolated syndrome [CIS]/radiologically isolated syndrome [RIS], 35 without RIS/CIS/MS). Subsequently, we assessed APRL's performance by comparing its results with manual PRL assessments carried out by a team of trained raters.Results: Among the 92 participants, expert raters identified 5637 white matter lesions and 148 PRLs. The automated segmentation method successfully captured 115 (78%) of the manually identified PRLs. Within these 115 identified lesions, APRL differentiated between manually identified PRLs and non‐PRLs with an area under the curve (AUC) of .73 (95% confidence interval [CI]: [.68, .78]). At the subject level, the count of APRL‐identified PRLs predicted MS diagnosis with an AUC of .69 (95% CI: [.57, .81]).Conclusion: Our study demonstrated APRL's capability to differentiate between PRLs and lesions without paramagnetic rims in a multicenter study. Automated identification of PRLs offers greater efficiency over manual identification and could facilitate large‐scale assessments of PRLs in clinical trials.
- 16 August 2023
- Published by Wiley in Journal of Neuroimaging
- Vol. 33 (6) , 941-952
Intersite brain MRI volumetric biases persist even in a harmonized multisubject study of multiple sclerosis
Background and PurposeMulticenter study designs involving a variety of MRI scanners have become increasingly common. However, these present the issue of biases in image-based measures due to scanner or site differences. To assess these biases, we imaged 11 volunteers with multiple sclerosis (MS) with scan and rescan data at four sites. MethodsImages were acquired on Siemens or Philips scanners at 3 Tesla. Automated white matter lesion detection and whole-brain, gray and white matter, and thalamic volumetry were performed, as well as expert manual delineations of T1 magnetization-prepared rapid acquisition gradient echo and T2 fluid-attenuated inversion recovery lesions. Random-effect and permutation-based nonparametric modeling was performed to assess differences in estimated volumes within and across sites. ResultsRandom-effect modeling demonstrated model assumption violations for most comparisons of interest. Nonparametric modeling indicated that site explained >50% of the variation for most estimated volumes. This expanded to >75% when data from both Siemens and Philips scanners were included. Permutation tests revealed significant differences between average inter- and intrasite differences in most estimated brain volumes (P < .05). The automatic activation of spine coil elements during some acquisitions resulted in a shading artifact in these images. Permutation tests revealed significant differences between thalamic volume measurements from acquisitions with and without this artifact. ConclusionDifferences in brain volumetry persisted across MR scanners despite protocol harmonization. These differences were not well explained by variance component modeling; however, statistical innovations for mitigating intersite differences show promise in reducing biases in multicenter studies of MS.
- 16 August 2023
- Published by Wiley in Journal of Neuroimaging
- Vol. 33 (6) , 941-952
Intersite brain MRI volumetric biases persist even in a harmonized multisubject study of multiple sclerosis
Background and PurposeMulticenter study designs involving a variety of MRI scanners have become increasingly common. However, these present the issue of biases in image-based measures due to scanner or site differences. To assess these biases, we imaged 11 volunteers with multiple sclerosis (MS) with scan and rescan data at four sites. MethodsImages were acquired on Siemens or Philips scanners at 3 Tesla. Automated white matter lesion detection and whole-brain, gray and white matter, and thalamic volumetry were performed, as well as expert manual delineations of T1 magnetization-prepared rapid acquisition gradient echo and T2 fluid-attenuated inversion recovery lesions. Random-effect and permutation-based nonparametric modeling was performed to assess differences in estimated volumes within and across sites. ResultsRandom-effect modeling demonstrated model assumption violations for most comparisons of interest. Nonparametric modeling indicated that site explained >50% of the variation for most estimated volumes. This expanded to >75% when data from both Siemens and Philips scanners were included. Permutation tests revealed significant differences between average inter- and intrasite differences in most estimated brain volumes (P < .05). The automatic activation of spine coil elements during some acquisitions resulted in a shading artifact in these images. Permutation tests revealed significant differences between thalamic volume measurements from acquisitions with and without this artifact. ConclusionDifferences in brain volumetry persisted across MR scanners despite protocol harmonization. These differences were not well explained by variance component modeling; however, statistical innovations for mitigating intersite differences show promise in reducing biases in multicenter studies of MS.
- Open Access
Inter-scanner brain MRI volumetric biases persist even in a harmonized multi-subject study of multiple sclerosis
Background/Purpose: Multicenter study designs involving a variety of MRI scanners have become increasingly common. However, these present the issue of biases in image-based measures due to scanner or site differences. To assess these biases, we imaged 11 volunteers with multiple sclerosis (MS) with scan and rescan data at 4 sites. Materials and Methods: Images were acquired on Siemens or Philips scanners at 3-tesla. Automated white matter lesion detection and whole brain, gray and white matter, and thalamic volumetry were performed, as well as expert manual delineations of T1 and T2 (FLAIR) lesions. Random effect and permutation-based nonparametric modeling was performed to assess differences in estimated volumes within and across sites. Results: Random effect modeling demonstrated model assumption violations for most comparisons of interest. Non-parametric modeling indicated that site explained > 50% of the variation for most estimated volumes. This expanded to > 75% when data from both Siemens and Philips scanners were included. Permutation tests revealed significant differences between average inter- and intra-scanner differences in most estimated brain volumes ( P < .05). The automatic activation of spine coil elements during some acquisitions resulted in a shading artifact in these images. Permutation tests revealed significant differences between thalamic volume measurements from acquisitions with and without this artifact. Conclusion: Differences in brain volumetry persisted across MR scanners despite protocol harmonization. These differences were not well explained by variance component modeling; however, statistical innovations for mitigating inter-scanner differences show promise in reducing biases in multi-center studies of MS.
Open AccessInter-scanner brain MRI volumetric biases persist even in a harmonized multi-subject study of multiple sclerosis
Background/Purpose: Multicenter study designs involving a variety of MRI scanners have become increasingly common. However, these present the issue of biases in image-based measures due to scanner or site differences. To assess these biases, we imaged 11 volunteers with multiple sclerosis (MS) with scan and rescan data at 4 sites. Materials and Methods: Images were acquired on Siemens or Philips scanners at 3-tesla. Automated white matter lesion detection and whole brain, gray and white matter, and thalamic volumetry were performed, as well as expert manual delineations of T1 and T2 (FLAIR) lesions. Random effect and permutation-based nonparametric modeling was performed to assess differences in estimated volumes within and across sites. Results: Random effect modeling demonstrated model assumption violations for most comparisons of interest. Non-parametric modeling indicated that site explained > 50% of the variation for most estimated volumes. This expanded to > 75% when data from both Siemens and Philips scanners were included. Permutation tests revealed significant differences between average inter- and intra-scanner differences in most estimated brain volumes ( P < .05). The automatic activation of spine coil elements during some acquisitions resulted in a shading artifact in these images. Permutation tests revealed significant differences between thalamic volume measurements from acquisitions with and without this artifact. Conclusion: Differences in brain volumetry persisted across MR scanners despite protocol harmonization. These differences were not well explained by variance component modeling; however, statistical innovations for mitigating inter-scanner differences show promise in reducing biases in multi-center studies of MS.
- Open Access
Fully Automated Detection of Paramagnetic Rims in Multiple Sclerosis Lesions on 3T Susceptibility-Based MR Imaging
Background and Purpose: The presence of a paramagnetic rim around a white matter lesion has recently been shown to be a hallmark of a particular pathological type of multiple sclerosis (MS) lesion. Increased prevalence of these paramagnetic rim lesions (PRLs) is associated with a more severe disease course in MS. The identification of these lesions is time-consuming to perform manually. We present a method to automatically detect PRLs on 3T T2*-phase images. Methods: T1-weighted, T2-FLAIR, and T2*-phase MRI of the brain were collected at 3T for 19 subjects with MS. The images were then processed with lesion segmentation, lesion center detection, lesion labelling, and lesion-level radiomic feature extraction. A total of 877 lesions were identified, 118 (13%) of which contained a paramagnetic rim. We divided our data into a training set (15 patients, 673 lesions) and a testing set (4 patients, 204 lesions). We fit a random forest classification model on the training set and assessed our ability to classify lesions as PRL on the test set. Results: The number of PRLs per subject identified via our automated lesion labelling method was highly correlated with the gold standard count of PRLs per subject, r = 0.91 (95% CI [0.79, 0.97]). The classification algorithm using radiomic features can classify a lesion as PRL or not with an area under the curve of 0.80 (95% CI [0.67, 0.86]). Conclusion: This study develops a fully automated technique for the detection of paramagnetic rim lesions using standard T1 and FLAIR sequences and a T2*phase sequence obtained on 3T MR images. Highlights: A fully automated method for both the identification and classification of paramagnetic rim lesions is proposed. Radiomic features in conjunction with machine learning algorithms can accurately classify paramagnetic rim lesions. Challenges for classification are largely driven by heterogeneity between lesions, including equivocal rim signatures and lesion location.
Open AccessFully Automated Detection of Paramagnetic Rims in Multiple Sclerosis Lesions on 3T Susceptibility-Based MR Imaging
Background and Purpose: The presence of a paramagnetic rim around a white matter lesion has recently been shown to be a hallmark of a particular pathological type of multiple sclerosis (MS) lesion. Increased prevalence of these paramagnetic rim lesions (PRLs) is associated with a more severe disease course in MS. The identification of these lesions is time-consuming to perform manually. We present a method to automatically detect PRLs on 3T T2*-phase images. Methods: T1-weighted, T2-FLAIR, and T2*-phase MRI of the brain were collected at 3T for 19 subjects with MS. The images were then processed with lesion segmentation, lesion center detection, lesion labelling, and lesion-level radiomic feature extraction. A total of 877 lesions were identified, 118 (13%) of which contained a paramagnetic rim. We divided our data into a training set (15 patients, 673 lesions) and a testing set (4 patients, 204 lesions). We fit a random forest classification model on the training set and assessed our ability to classify lesions as PRL on the test set. Results: The number of PRLs per subject identified via our automated lesion labelling method was highly correlated with the gold standard count of PRLs per subject, r = 0.91 (95% CI [0.79, 0.97]). The classification algorithm using radiomic features can classify a lesion as PRL or not with an area under the curve of 0.80 (95% CI [0.67, 0.86]). Conclusion: This study develops a fully automated technique for the detection of paramagnetic rim lesions using standard T1 and FLAIR sequences and a T2*phase sequence obtained on 3T MR images. Highlights: A fully automated method for both the identification and classification of paramagnetic rim lesions is proposed. Radiomic features in conjunction with machine learning algorithms can accurately classify paramagnetic rim lesions. Challenges for classification are largely driven by heterogeneity between lesions, including equivocal rim signatures and lesion location.