MRI Highly Accelerated Wave‐CAIPI T1‐SPACE versus Standard T1‐SPACE to detect brain gadolinium‐enhancing lesions at 3T
- 3 June 2021
- journal article
- research article
- Published by Wiley in Journal of Neuroimaging
- Vol. 31 (5) , 893-901
Abstract
Background and Purpose: High‐resolution three‐dimensional (3D) post‐contrast imaging of the brain is essential for comprehensive evaluation of inflammatory, neoplastic, and neurovascular diseases of the brain. 3D T1‐weighted spin‐echo‐based sequences offer increased sensitivity for the detection of enhancing lesions but are relatively prolonged examinations. We evaluated whether a highly accelerated Wave‐controlled aliasing in parallel imaging (Wave‐CAIPI) post‐contrast 3D T1‐sampling perfection with application‐optimized contrasts using different flip angle evolutions (T1‐SPACE) sequence (Wave‐T1‐SPACE) was noninferior to the standard high‐resolution 3D T1‐SPACE sequence for visualizing enhancing lesions with comparable diagnostic quality. Methods: One hundred and three consecutive patients were prospectively evaluated with a standard post‐contrast 3D T1‐SPACE sequence (acquisition time [TA] = 4 min 19 s) and an optimized Wave‐CAIPI 3D T1‐SPACE sequence (TA = 1 min 40 s) that was nearly three times faster than the standard sequence. Two blinded neuroradiologists performed a head‐to‐head comparison to evaluate the visualization of enhancing pathology, perception of artifacts, and overall diagnostic quality. A 15% margin was used to test whether post‐contrast Wave‐T1‐SPACE was noninferior to standard T1‐SPACE. Results: Wave‐T1‐SPACE was noninferior to standard T1‐SPACE for delineating parenchymal and meningeal enhancing pathology ( p < 0.01). Wave‐T1‐SPACE showed marginally higher background noise compared to the standard sequence and was noninferior in the overall diagnostic quality ( p = 0.03). Conclusions: Our findings show that Wave‐T1‐SPACE was noninferior to standard T1‐SPACE for visualization of enhancing pathology and overall diagnostic quality with a three‐fold reduction in acquisition time compared to the standard sequence. Wave‐T1‐SPACE may be used to accelerate 3D post‐contrast T1‐weighted spin‐echo imaging without loss of clinically important information.Keywords
This publication has 15 references indexed in Scilit:
- Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI TechniquesAmerican Journal of Neuroradiology, 2019
- Autocalibrated wave‐CAIPI reconstruction; Joint optimization of k‐space trajectory and parallel imaging reconstructionMagnetic Resonance in Medicine, 2016
- Wave‐CAIPI for highly accelerated 3D imagingMagnetic Resonance in Medicine, 2014
- Optimized three‐dimensional fast‐spin‐echo MRIJournal of Magnetic Resonance Imaging, 2014
- How to Demonstrate Similarity by Using Noninferiority and Equivalence Statistical Testing in Radiology ResearchRadiology, 2013
- Usefulness of Contrast-Enhanced T1-Weighted Sampling Perfection with Application-Optimized Contrasts by Using Different Flip Angle Evolutions in Detection of Small Brain Metastasis at 3T MR Imaging: Comparison with Magnetization-Prepared Rapid Acquisition of Gradient Echo ImagingAmerican Journal of Neuroradiology, 2009
- Optimized T1‐weighted contrast for single‐slab 3D turbo spin‐echo imaging with long echo trains: Application to whole‐brain imagingMagnetic Resonance in Medicine, 2007
- Factors influencing contrast in fast spin-echo MR imagingMagnetic Resonance Imaging, 1992
- High agreement but low Kappa: I. the problems of two paradoxesJournal of Clinical Epidemiology, 1990
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977