AFAugusto Lio da Mota Goncalves Filho

Augusto Lio da Mota Goncalves Filho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Augusto Lio da Mota Goncalves Filho has a total of 78 co-authors. Here are the top co-authors by number of shared publications:

  • Azadeh Tabari

    From the Department of Radiology (M.L., B.P.A., A.T., M.G.F.L., M.H.L., P.W.S., O.R., S.Y.H., J.C.), Massachusetts General Hospital, Boston, Massachusetts

    3 shared publications
  • John Conklin

    Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, USA

    3 shared publications
  • John Conklin

    Department of Radiology, A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Boston, USA

    3 shared publications
  • Kawin Setsompop

    Department of Electrical Engineering Stanford University Stanford California USA

    3 shared publications
  • Maria Gabriela Figueiro Longo

    From the Department of Department of Radiology, Massachusetts General Hospital, Boston, MA, United States

    3 shared publications
  • Otto Rapalino

    Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, USA

    3 shared publications

Latest Publications

  • Open Access

    Machine-Learning-Assisted Detection of Residual or Recurrent Filling in Endovascularly Treated Intracranial Aneurysms on TOF-MRA: A Pilot Study

    by Sushmitha Puttappa Shivagange, Augusto da Mota Goncalves Filho, Mohamed S. Hefny, Eduardo Portela de Oliveira

    Background and Purpose: Surveillance TOF-MRA is a non-invasive alternative to digital subtraction angiography (DSA) for detecting aneurysm residual/recurrence after endovascular embolization but is limited by coil/WEB device-related susceptibility artifact and inter-reader variability. We evaluated a supervised machine-learning classifier for detecting residuals and/or recurrence on surveillance TOF-MRA obtained 3–6 months after endovascular embolization, referenced against the Raymond–Roy Occlusion Classification (RROC) class assigned on the surveillance TOF-MRA itself by a single, non-blinded neuroradiologist who had access to the completion DSA and 24–48 h post-procedural MRA. Materials and Methods: In this single-center retrospective pilot study, 53 of 55 eligible adults with intrasaccular endovascular embolization (coiling or WEB device, 2020–2024) were analyzed after excluding 2 for suboptimal MRA quality (RROC I: n = 13, II: n = 18, III: n = 27); the final analytical cohort comprised 58 aneurysms from 53 unique patients. Radiomic features from a class-agnostic 3 mm peri-device region were extracted with PyRadiomics and evaluated using L1-regularized logistic regression, calibrated linear SVM, and random forest. Model evaluation used 100 repetitions of 5-fold patient-grouped nested cross-validation, with all aneurysms from the same patient kept within the same fold and preprocessing, feature selection, hyperparameter tuning, and model fitting confined to training data. A post hoc exploratory subgroup analysis excluded the morphologically intermediate Class II cases. Results: In the primary analysis of 58 aneurysms from 53 patients, L1-regularized logistic regression yielded an aggregated repeated out-of-fold AUC of 0.716 (95% patient-cluster bootstrap CI 0.566–0.856), sensitivity 0.800, specificity 0.462, negative predictive value 0.400, and balanced accuracy 0.631 at a 0.50 threshold. The mean AUC across the 100 individual cross-validation repetitions, which is a different estimate, was 0.601 (SD 0.088) for logistic regression, 0.631 (SD 0.056) for random forest and 0.555 (SD 0.097) for the calibrated linear SVM. In the post hoc exploratory Class I versus III analysis (40 aneurysms from 38 patients), L1 logistic regression yielded AUC 0.832 (95% CI 0.704–0.946), sensitivity 0.852, specificity 0.692, and balanced accuracy 0.772. The subgroup represents a different, more separated classification task and is not directly comparable with the full cohort. Of 45 outcome-positive aneurysms, 42% were persistent residual filling and 58% interval recurrence. Conclusion s: This pilot analysis demonstrates the technical feasibility of the patient-grouped radiomics-based classification of post-treatment surveillance TOF-MRA. The performance estimates remain preliminary because of the small single-center cohort, limited number of negative cases, scanner/device heterogeneity, and absence of external validation. The exploratory Class I versus III results should not be interpreted as evidence of improved clinical performance and warrant external multicenter validation. The specificity and negative predictive value were low, the incremental value of radiomics beyond simpler device- or morphology-based approaches has not been established, and the model is not ready for clinical use.

  • Sinonasal Organized Hematoma

    by Albert Jiao, Augusto Da Mota Gonçalves Filho, Maria Lucia Brun-Vergara, Irene Dixe de Oliveira Santo, Amit Agarwal

  • Ovarian Fibromatosis

    by Michael Enea, Parisa Khoshpouri, Augusto Lio da Mota Goncalves Filho, Kaitlin M. Zaki-Metias, Pouria Rouzrokh


  • Encrusted Pyelitis

    by Augusto Goncalves Filho, Christian Gomez, Vaibhav Gulati, Tarek El-Diasty, Haytham Shebel

  • Open Access

    Malignant transformation of vestibular schwannoma after radiation therapy

    by Anastasia Drakos, Augusto Goncalves Filho, John Woulfe, Paulo Puac Polanco, Eduardo Portela de Oliveira


  • Open Access

    Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings

    by Min Lang, Bryan Clifford, Wei-Ching Lo, Brooks P. Applewhite, Azadeh Tabari, Augusto Lio M. Goncalves Filho, Zahra Hosseini, Maria Gabriela Figueiro Longo, Stephen F. Cauley, Kawin Setsompop, et al.

    BACKGROUND AND PURPOSE: The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS: Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS: The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS: The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.


  • Diagnostic evaluation of deep learning accelerated lumbar spine MRI

    by Komal M Awan, Augusto Lio M Goncalves Filho, Azadeh Tabari, Brooks P Applewhite, Min Lang, Wei-Ching Lo, Robert Sellers, Peter Kollasch, Bryan Clifford, Dominik Nickel, et al.

    Background and Purpose: Deep learning (DL) accelerated MR techniques have emerged as a promising approach to accelerate routine MR exams. While prior studies explored DL acceleration for specific lumbar MRI sequences, a gap remains in comprehending the impact of a fully DL-based MRI protocol on scan time and diagnostic quality for routine lumbar spine MRI. To address this, we assessed the image quality and diagnostic performance of a DL-accelerated lumbar spine MRI protocol in comparison to a conventional protocol. Methods: We prospectively evaluated 36 consecutive outpatients undergoing non-contrast enhanced lumbar spine MRIs. Both protocols included sagittal T1, T2, STIR, and axial T2-weighted images. Two blinded neuroradiologists independently reviewed images for foraminal stenosis, spinal canal stenosis, nerve root compression, and facet arthropathy. Grading comparison employed the Wilcoxon signed rank test. For the head-to-head comparison, a 5-point Likert scale to assess image quality, considering artifacts, signal-to-noise ratio (SNR), anatomical structure visualization, and overall diagnostic quality. We applied a 15% noninferiority margin to determine whether the DL-accelerated protocol was noninferior. Results: No significant differences existed between protocols when evaluating foraminal and spinal canal stenosis, nerve compression, or facet arthropathy (all p > .05). The DL-spine protocol was noninferior for overall diagnostic quality and visualization of the cord, CSF, intervertebral disc, and nerve roots. However, it exhibited reduced SNR and increased artifact perception. Interobserver reproducibility ranged from moderate to substantial (κ = 0.50–0.76). Conclusion: Our study indicates that DL reconstruction in spine imaging effectively reduces acquisition times while maintaining comparable diagnostic quality to conventional MRI.


  • An artificial intelligence‐accelerated 2‐minute multi‐shot echo planar imaging protocol for comprehensive high‐quality clinical brain imaging

    by Bryan Clifford, John Conklin, Susie Y. Huang, Thorsten Feiweier, Zahra Hosseini, Augusto Lio M. Goncalves Filho, Azadeh Tabari, Serdest Demir, Wei‐Ching Lo, Maria Gabriela Figueiro Longo, et al.

    Purpose: We introduce and validate an artificial intelligence (AI)‐accelerated multi‐shot echo‐planar imaging (msEPI)‐based method that provides T1w, T2w, , T2‐FLAIR, and DWI images with high SNR, high tissue contrast, low specific absorption rates (SAR), and minimal distortion in 2 minutes.Methods: The rapid imaging technique combines a novel machine learning (ML) scheme to limit g‐factor noise amplification and improve SNR, a magnetization transfer preparation module to provide clinically desirable contrast, and high per‐shot EPI undersampling factors to reduce distortion. The ML training and image reconstruction incorporates a tunable parameter for controlling the level of denoising/smoothness. The performance of the reconstruction method is evaluated across various acceleration factors, contrasts, and SNR conditions. The 2‐minute protocol is directly compared to a 10‐minute clinical reference protocol through deployment in a clinical setting, where five representative cases with pathology are examined.Results: Optimization of custom msEPI sequences and protocols was performed to balance acquisition efficiency and image quality compared to the five‐fold longer clinical reference. Training data from 16 healthy subjects across multiple contrasts and orientations were used to produce ML networks at various acceleration levels. The flexibility of the ML reconstruction was demonstrated across SNR levels, and an optimized regularization was determined through radiological review. Network generalization toward novel pathology, unobserved during training, was illustrated in five clinical case studies with clinical reference images provided for comparison.Conclusion: The rapid 2‐minute msEPI‐based protocol with tunable ML reconstruction allows for advantageous trade‐offs between acquisition speed, SNR, and tissue contrast when compared to the five‐fold slower standard clinical reference exam.


  • Evaluation of Ultrafast Wave–Controlled Aliasing in Parallel Imaging 3D-FLAIR in the Visualization and Volumetric Estimation of Cerebral White Matter Lesions

    by C. Ngamsombat, A.L.M. Gonçalves Filho, M.G.F. Longo, S.F. Cauley, K. Setsompop, J.E. Kirsch, Q. Tian, Q. Fan, D. Polak, W. Liu, et al.

    BACKGROUND AND PURPOSE: Our aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave–controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting. MATERIALS AND METHODS: Forty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student t tests, intraclass correlation coefficients, relative lesion volume difference, and Dice similarity coefficients were used to compare volumetric measurements among sequences. Two blinded neuroradiologists evaluated the visualization of white matter lesions, artifacts, and overall diagnostic quality using a predefined 5-point scale. RESULTS: Standard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84–0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (P < .001), and there were fewer pulsation artifacts on Wave-FLAIR compared with standard FLAIR (P < .001). CONCLUSIONS: Ultrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.


  • MRI Highly Accelerated Wave‐CAIPI T1‐SPACE versus Standard T1‐SPACE to detect brain gadolinium‐enhancing lesions at 3T

    by Augusto Lio M. Goncalves Filho, M. Gabriela Figueiro Longo, John Conklin, Stephen F. Cauley, Daniel Polak, Wei Liu, Daniel N. Splitthoff, Wei‐Ching Lo, John E. Kirsch, Kawin Setsompop, et al.

    Background and Purpose: High‐resolution three‐dimensional (3D) post‐contrast imaging of the brain is essential for comprehensive evaluation of inflammatory, neoplastic, and neurovascular diseases of the brain. 3D T1‐weighted spin‐echo‐based sequences offer increased sensitivity for the detection of enhancing lesions but are relatively prolonged examinations. We evaluated whether a highly accelerated Wave‐controlled aliasing in parallel imaging (Wave‐CAIPI) post‐contrast 3D T1‐sampling perfection with application‐optimized contrasts using different flip angle evolutions (T1‐SPACE) sequence (Wave‐T1‐SPACE) was noninferior to the standard high‐resolution 3D T1‐SPACE sequence for visualizing enhancing lesions with comparable diagnostic quality. Methods: One hundred and three consecutive patients were prospectively evaluated with a standard post‐contrast 3D T1‐SPACE sequence (acquisition time [TA] = 4 min 19 s) and an optimized Wave‐CAIPI 3D T1‐SPACE sequence (TA = 1 min 40 s) that was nearly three times faster than the standard sequence. Two blinded neuroradiologists performed a head‐to‐head comparison to evaluate the visualization of enhancing pathology, perception of artifacts, and overall diagnostic quality. A 15% margin was used to test whether post‐contrast Wave‐T1‐SPACE was noninferior to standard T1‐SPACE. Results: Wave‐T1‐SPACE was noninferior to standard T1‐SPACE for delineating parenchymal and meningeal enhancing pathology ( p < 0.01). Wave‐T1‐SPACE showed marginally higher background noise compared to the standard sequence and was noninferior in the overall diagnostic quality ( p = 0.03). Conclusions: Our findings show that Wave‐T1‐SPACE was noninferior to standard T1‐SPACE for visualization of enhancing pathology and overall diagnostic quality with a three‐fold reduction in acquisition time compared to the standard sequence. Wave‐T1‐SPACE may be used to accelerate 3D post‐contrast T1‐weighted spin‐echo imaging without loss of clinically important information.