Assessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses
Open Access
- 29 September 2021
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 10246
Abstract
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (ΣVOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of ΣVOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between ΣVOCs and participants’ relaxation (OR: 2.86, 95%CI: 1.24–6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of ΣVOCs than that with higher levels (OR: 3.03, 95%CI: 1.23–7.50). Therefore, the reduction of ΣVOCs and odors in indoor air would have an effect, which is the promotion of relaxation.Keywords
Funding Information
- Sekisui House Ltd. and Japan Society for the Promotion of Science (JSPS) Grants-in-Aid for Scientific Research (C) ((19K12455), (18K13885))
- JST OPERA Program (JPMJOP1831)
This publication has 40 references indexed in Scilit:
- Prevalence and Characteristics of Chemical Intolerance: A Japanese Population-Based StudyArchives of Environmental & Occupational Health, 2014
- Improving fluid intelligence with training on working memory: a meta-analysisPsychonomic Bulletin & Review, 2014
- Correlating the symptoms of sick-building syndrome to indoor VOCs concentration levels and odourIndoor and Built Environment, 2013
- Benefits and costs of improved IEQ in U.S. officesIndoor Air, 2011
- Ventilation rates and health: multidisciplinary review of the scientific literatureIndoor Air, 2011
- The effects of air temperature on office workers’ well-being, workload and productivity-evaluated with subjective ratingsApplied Ergonomics, 2010
- Reference Ranges for Exhaled Nitric Oxide Fraction in Healthy Japanese Adult PopulationAllergology International, 2010
- Persistent allergic rhinitis and indoor air quality perception - an experimental approachIndoor Air, 2006
- Thalamic Mechanisms of EEG Alpha Rhythms and Their Pathological ImplicationsThe Neuroscientist, 2005
- The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply ratesIndoor Air, 2004