Kayo Tsumura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kayo Tsumura has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chisato Mori
Department of Sustainable Health Science, Center for Preventive Medical Sciences, Chiba University, Chiba, Japan
6 shared publications - Norimichi Suzuki
Center for Preventive Medical Sciences, Chiba University, Chiba 263-8522, Japan
6 shared publications - Emiko Todaka
Department of Global Preventive Medicine, Center for Preventive Medical Sciences, Chiba University, 1-33 Yayoicho, Inage-ku, Chiba-si 263-8522, Chiba, Japan
5 shared publications - Hiroko Nakaoka
Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan
5 shared publications - Masamichi Hanazato
Center for Preventive Medical Sciences, Chiba University, Chiba, Japan
5 shared publications - Yoshitake Nakayama
Center for Preventive Medical Sciences, Chiba University, 6-2-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan
5 shared publications
Latest Publications
- Open Access
Second phase Chiba study of mother and child health (C-MACH): Japanese birth cohort study with multiomics analyses
Purpose: Epidemiological studies have reported that environmental factors from fetal period to early childhood can influence the risk of non-communicable diseases in adulthood. This concept has been termed the developmental origins of health and disease (DOHaD). The Chiba study of Mother and Child Health (C-MACH) is a DOHaD concept-based birth cohort study which started in 2014. This study aims to investigate the effects of genetic and environmental factors, particularly fetal and postnatal living environment, on children’s health. We also aim to identify candidate biomarkers for their health status. Moreover, the second phase study of C-MACH which was initiated in 2021 aimed at expanding the sample size, especially for gut microbiota and epigenomic analysis; it also aimed at clarifying the impact of the coronavirus disease 2019 (COVID-19) pandemic on children’s health. Participants: This study consists of four hospital-based cohorts. Women who were 2, with 74.5% of the women having a BMI of 18.5–24.9 kg/m2. About 5.2% of the women smoked cigarettes during the early stages of pregnancy. Future plans: The primary study outcomes are allergies, obesity, endocrine and metabolic disorders and developmental difficulties in children. Variables related to genome, metabolome, epigenome, gut microbiota and exposome will be evaluated as health-related factors. The relationships between these outcomes and the health-related factors will be analysed.
Open AccessSecond phase Chiba study of mother and child health (C-MACH): Japanese birth cohort study with multiomics analyses
Purpose: Epidemiological studies have reported that environmental factors from fetal period to early childhood can influence the risk of non-communicable diseases in adulthood. This concept has been termed the developmental origins of health and disease (DOHaD). The Chiba study of Mother and Child Health (C-MACH) is a DOHaD concept-based birth cohort study which started in 2014. This study aims to investigate the effects of genetic and environmental factors, particularly fetal and postnatal living environment, on children’s health. We also aim to identify candidate biomarkers for their health status. Moreover, the second phase study of C-MACH which was initiated in 2021 aimed at expanding the sample size, especially for gut microbiota and epigenomic analysis; it also aimed at clarifying the impact of the coronavirus disease 2019 (COVID-19) pandemic on children’s health. Participants: This study consists of four hospital-based cohorts. Women who were 2, with 74.5% of the women having a BMI of 18.5–24.9 kg/m2. About 5.2% of the women smoked cigarettes during the early stages of pregnancy. Future plans: The primary study outcomes are allergies, obesity, endocrine and metabolic disorders and developmental difficulties in children. Variables related to genome, metabolome, epigenome, gut microbiota and exposome will be evaluated as health-related factors. The relationships between these outcomes and the health-related factors will be analysed.
- Open Access
- 29 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 10246
Assessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (ΣVOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of ΣVOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between ΣVOCs and participants’ relaxation (OR: 2.86, 95%CI: 1.24–6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of ΣVOCs than that with higher levels (OR: 3.03, 95%CI: 1.23–7.50). Therefore, the reduction of ΣVOCs and odors in indoor air would have an effect, which is the promotion of relaxation.
- 29 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 10246
Open AccessAssessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (ΣVOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of ΣVOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between ΣVOCs and participants’ relaxation (OR: 2.86, 95%CI: 1.24–6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of ΣVOCs than that with higher levels (OR: 3.03, 95%CI: 1.23–7.50). Therefore, the reduction of ΣVOCs and odors in indoor air would have an effect, which is the promotion of relaxation.
- Open Access
- 1 January 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 750, 141635
Association between sum of volatile organic compounds and occurrence of building-related symptoms in humans: A study in real full-scale laboratory houses
- 1 January 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 750, 141635
Open AccessAssociation between sum of volatile organic compounds and occurrence of building-related symptoms in humans: A study in real full-scale laboratory houses
- Open Access
- 16 March 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (6) , 1940
Concentrations of Formic Acid, Acetic Acid, and Ammonia in Newly Constructed Houses
Herein, the concentrations of formic acid, acetic acid, and ammonia in samples of indoor air for 47 new houses were measured two weeks after completion. The houses were fabricated with light-gauge steel structures. The measurements were performed in living rooms and bedrooms without furniture and outdoors. Air samples were analyzed using ion chromatography. The mean values were 28 (living room), 30 (bedroom), and 20 μg m−3 (outdoor air) for formic acid; 166 (living room), 151 (bedroom), and 51 μg m−3 (outdoor air) for acetic acid; and 73 (living room), 76 (bedroom), and 21 μg m−3 (outdoor air) for ammonia. The total values of the three substances accounted for 39.4–40.7% of the sum of chemical compound values. The analyzed compounds were indicated by two principal components (PC), PC1 (30.1%) and PC2 (9%), with 39.1% total variance. Formic acid, acetic acid, and ammonia were positively aligned with PC1 and negatively aligned with PC2. Factors such as room temperature, aldehydes, and phthalates were positively aligned with PC1 and negatively aligned with PC2. Furthermore, concentrations of formic acid, acetic acid, and ammonia were significantly and positively correlated with room temperature (p < 0.05).
- 16 March 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (6) , 1940
Open AccessConcentrations of Formic Acid, Acetic Acid, and Ammonia in Newly Constructed Houses
Herein, the concentrations of formic acid, acetic acid, and ammonia in samples of indoor air for 47 new houses were measured two weeks after completion. The houses were fabricated with light-gauge steel structures. The measurements were performed in living rooms and bedrooms without furniture and outdoors. Air samples were analyzed using ion chromatography. The mean values were 28 (living room), 30 (bedroom), and 20 μg m−3 (outdoor air) for formic acid; 166 (living room), 151 (bedroom), and 51 μg m−3 (outdoor air) for acetic acid; and 73 (living room), 76 (bedroom), and 21 μg m−3 (outdoor air) for ammonia. The total values of the three substances accounted for 39.4–40.7% of the sum of chemical compound values. The analyzed compounds were indicated by two principal components (PC), PC1 (30.1%) and PC2 (9%), with 39.1% total variance. Formic acid, acetic acid, and ammonia were positively aligned with PC1 and negatively aligned with PC2. Factors such as room temperature, aldehydes, and phthalates were positively aligned with PC1 and negatively aligned with PC2. Furthermore, concentrations of formic acid, acetic acid, and ammonia were significantly and positively correlated with room temperature (p < 0.05).
- Open Access
- 17 December 2019
- Published by Springer Nature in Environmental Health and Preventive Medicine
- Vol. 24 (1) , 1-10
Prevalence and risk factors of pre-sick building syndrome: characteristics of indoor environmental and individual factors
Background: With the aim to prevent sick building syndrome and worsening of allergic symptoms, primarily resulting from the indoor environment, the relationships among people’s residential environment in recent years, their lifestyle habits, their awareness, and their symptoms were investigated using an online survey. Methods: In the survey, respondents experiencing symptoms specific to sick building syndrome, although they were not diagnosed with sick building syndrome, were categorized in the pre-sick building syndrome group. The relationships among individual characteristics, residential environment, and individual awareness were analyzed. Results: Results showed that the prevalence of pre-sick building syndrome was high among young (aged 20–29 years) population of both sexes. In addition, “condensation,” “moisture,” “musty odors” in the house, and the “use of deodorant and fragrance” were all significantly associated with pre-sick building syndrome. Conversely, there was no significant association with recently built “wooden” houses that are highly airtight and have thermal insulation. Conclusions: Efficient “ventilation” plans and “ventilation” improvement and air conditioning systems to prevent mold and condensation in rooms are necessary to maintain a good, indoor environment that is beneficial for health. Efforts should also be made to encourage individuals to regularly clean and effectively ventilate their homes.
- 17 December 2019
- Published by Springer Nature in Environmental Health and Preventive Medicine
- Vol. 24 (1) , 1-10
Open AccessPrevalence and risk factors of pre-sick building syndrome: characteristics of indoor environmental and individual factors
Background: With the aim to prevent sick building syndrome and worsening of allergic symptoms, primarily resulting from the indoor environment, the relationships among people’s residential environment in recent years, their lifestyle habits, their awareness, and their symptoms were investigated using an online survey. Methods: In the survey, respondents experiencing symptoms specific to sick building syndrome, although they were not diagnosed with sick building syndrome, were categorized in the pre-sick building syndrome group. The relationships among individual characteristics, residential environment, and individual awareness were analyzed. Results: Results showed that the prevalence of pre-sick building syndrome was high among young (aged 20–29 years) population of both sexes. In addition, “condensation,” “moisture,” “musty odors” in the house, and the “use of deodorant and fragrance” were all significantly associated with pre-sick building syndrome. Conversely, there was no significant association with recently built “wooden” houses that are highly airtight and have thermal insulation. Conclusions: Efficient “ventilation” plans and “ventilation” improvement and air conditioning systems to prevent mold and condensation in rooms are necessary to maintain a good, indoor environment that is beneficial for health. Efforts should also be made to encourage individuals to regularly clean and effectively ventilate their homes.
- Open Access
- 28 October 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (21) , 4142
Indoor Air Quality Analysis of Newly Built Houses
Recently, people have become increasingly aware of potential health issues related to indoor environments. In this study, we measure the concentrations of various volatile organic compounds, carbonyl compounds, and semi-volatile organic compounds, as well as the ventilation rates, in 49 new houses with light-gauge steel structures one week after completion. The proper indoor air quality of new residential environments can be ensured by characterizing people’s exposure to certain chemicals and assessing future risks. Our results show that the concentrations of the measured compounds were lower than the guideline values set by the Ministry of Health, Labour and Welfare of Japan, and would continue to decrease. However, we observed that unregulated compounds, assumed to be substitutes for regulated solvents, contributed substantially to the total volatile organic compounds. To reduce indoor chemical exposure risks, the concentrations of these unregulated compounds should also be minimized. In addition, their sources need to be identified, and manufacture and use must be monitored. We believe it is important to select low-emission building materials for reducing residents’ exposure to indoor chemicals.
- 28 October 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (21) , 4142
Open AccessIndoor Air Quality Analysis of Newly Built Houses
Recently, people have become increasingly aware of potential health issues related to indoor environments. In this study, we measure the concentrations of various volatile organic compounds, carbonyl compounds, and semi-volatile organic compounds, as well as the ventilation rates, in 49 new houses with light-gauge steel structures one week after completion. The proper indoor air quality of new residential environments can be ensured by characterizing people’s exposure to certain chemicals and assessing future risks. Our results show that the concentrations of the measured compounds were lower than the guideline values set by the Ministry of Health, Labour and Welfare of Japan, and would continue to decrease. However, we observed that unregulated compounds, assumed to be substitutes for regulated solvents, contributed substantially to the total volatile organic compounds. To reduce indoor chemical exposure risks, the concentrations of these unregulated compounds should also be minimized. In addition, their sources need to be identified, and manufacture and use must be monitored. We believe it is important to select low-emission building materials for reducing residents’ exposure to indoor chemicals.