A solid-state amperometric sensor based on yttria-stabilized zirconia (YSZ) for the simultaneous measurement of CO and CO2 concentrations in inert gases was fabricated. The designed sensor consists of two electrically isolated ceramic cells made of YSZ and equipped with Pt electrodes. Ceramic capillaries connecting an inner gas chamber of each cell with the outside atmosphere serve as diffusion barriers. One of the cells is intended for sensing CO, whereas the other is for sensing CO2 in the gaseous atmosphere. The electrochemical response of the sensor was studied in the temperature range of 600–750 °C in the presence of up to 10% of CO and CO2 in nitrogen. The limiting currents of the two cells were shown to rise linearly with the relevant carbon oxide concentration, and no perceptible cross-sensitivity effect toward the other carbon oxide was found. The sensor demonstrated high stability and reproducibility of results and good dynamic characteristics. The novelty of this research lies in the development of a simple, reliable and fast solid-oxide sensor for simultaneous sensing of CO and CO2 in inert gases, which can be used for the control of atmosphere in, for example, pharmaceutical, chemical, food storage industries.Keywords
This publication has 22 references indexed in Scilit:
- A simple and low-cost amperometric sensor for measuring H2, CO, and CH4Sensors and Actuators B: Chemical, 2015
- Solid-state gas sensors for high temperature applications – a reviewJournal of Materials Chemistry A, 2014
- Semiconducting metal oxides as sensors for environmentally hazardous gasesSensors and Actuators B: Chemical, 2011
- Miniaturized Laser Spectroscopic CO Sensor for Industrial and Safety ApplicationsProcedia Chemistry, 2009
- A review of electrolyte and electrode materials for high temperature electrochemical CO2 and SO2 gas sensorsSensors and Actuators B: Chemical, 2008
- Impedance-metric Pt/YSZ/Au–Ga2O3 sensor for CO detection at high temperatureSensors and Actuators B: Chemical, 2005
- Trends in the development of solid state amperometric and potentiometric high temperature sensorsSolid State Ionics, 2000
- Defect structure of yttria-stabilized zirconia and its influence on the ionic conductivity at elevated temperaturesPhysical Review B, 1999
- Electrochemical blackening of yttria-stabilized zirconia – morphological instability of the moving reaction frontSolid State Ionics, 1999
- Carbon monoxide gas sensor made of stabilized zirconiaSolid State Ionics, 1980