Alexander Volkov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Volkov has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Anatoly S. Kalyakin
Institute of High Temperature Electrochemistry
5 shared publications - Liliya A. Dunyushkina
Institute of High-Temperature ElectrochemistryUB RAS, Russian Federation
3 shared publications - Anatoly Kalyakin
Institute of High Temperature Electrochemistry, Ural Branch of the Russian Academy of Sciences, 20 Akademicheskaya St., 620066 Ekaterinburg, Russia
2 shared publications - Dmitry A. Medvedev
Ural Federal University, Ekaterinburg
2 shared publications A. S. Kalyakin
Laboratory of Electrochemical Devices Based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry, 620066 Yekaterinburg, Russia
1 shared publication- Alexander Yu. Chuikin
Laboratory of Electrochemical Devices Based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry
1 shared publication
Latest Publications
- Open Access
- 17 June 2026
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 5 (2) , 20254071
YSZ-based underfiring sensor for simultaneous measurement of residual oxygen and unburnt species in flue gases
Flue gas analysis is essential for optimizing combustion efficiency, reducing fuel costs, and ensuring safety by detecting dangerous emissions like carbon monoxide. An amperometric YSZ-based sensor for simultaneous measurement of the concentrations of residual oxygen and unburnt species (CO, H2) in flue gases has been developed. The sensor has a simple structure and is easy to fabricate, providing a cost-effective solution. It demonstrates high sensitivity, good reproducibility and acceptable response time. The use of the sensor for the in-situ real-time analysis of flue gas will facilitate the optimization of air-fuel ratios, thereby preventing fuel wastage and hazardous emissions.
- 17 June 2026
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 5 (2) , 20254071
Open AccessYSZ-based underfiring sensor for simultaneous measurement of residual oxygen and unburnt species in flue gases
Flue gas analysis is essential for optimizing combustion efficiency, reducing fuel costs, and ensuring safety by detecting dangerous emissions like carbon monoxide. An amperometric YSZ-based sensor for simultaneous measurement of the concentrations of residual oxygen and unburnt species (CO, H2) in flue gases has been developed. The sensor has a simple structure and is easy to fabricate, providing a cost-effective solution. It demonstrates high sensitivity, good reproducibility and acceptable response time. The use of the sensor for the in-situ real-time analysis of flue gas will facilitate the optimization of air-fuel ratios, thereby preventing fuel wastage and hazardous emissions.
- Open Access
- 12 March 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243027
Stability and reproducibility of the amperometric sensors for oxygen concentration analysis in the nitrogen gas mixtures
The paper presents experimentally obtained results on the long-term stability tests of the solid electrolyte amperometric sensor output signal during the operation in the O2 + N2 gas mixtures. These data prove the stability and reproducibility of the output signal when measuring the oxygen concentration in air for 8000 hours. The output signal variation during the tests did not exceed ± 2 %. We performed four heating / cooling cycles of different durations, which did not influence either sensor integrity or operation characteristics. The structure of the solid electrolyte sensor and the solid electrolyte/electrode interfacial layer remained unchanged during the tests. Dynamic characteristics of the sensor, including the response time, were stable.
- 12 March 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243027
Open AccessStability and reproducibility of the amperometric sensors for oxygen concentration analysis in the nitrogen gas mixtures
The paper presents experimentally obtained results on the long-term stability tests of the solid electrolyte amperometric sensor output signal during the operation in the O2 + N2 gas mixtures. These data prove the stability and reproducibility of the output signal when measuring the oxygen concentration in air for 8000 hours. The output signal variation during the tests did not exceed ± 2 %. We performed four heating / cooling cycles of different durations, which did not influence either sensor integrity or operation characteristics. The structure of the solid electrolyte sensor and the solid electrolyte/electrode interfacial layer remained unchanged during the tests. Dynamic characteristics of the sensor, including the response time, were stable.
- Open Access
- 12 January 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243026
Stability and reproducibility of solid electrolyte amperometry sensors at the analysis of hydrogen in nitrogen-containing gas mixtures
This paper illustrates the results of long-term tests on the stability of the output signal of the solid electrolyte amperometry sensor when measuring the hydrogen concentration in the H2 + N2 gaseous mixture. The obtained experimental data verify the stability and reproducibility of the sensor output signal for hydrogen concentration measurements in the nitrogen-containing gaseous mixture during 8000 h of operation. The output signal drift, i.e., the limiting current value, was insignificant, less than ± 5 %. The sensor operation was performed at 3 temperature shifts with different time intervals; these changes did not have any impact either on the sensor integrity or on its operation. The structure of the solid electrolyte sensor, intermediate solid electrolyte / electrode layer and electrodes did not undergo any significant changes during operation. The dynamic characteristics of the sensor, the response time in particular, remained stable during the operation.
- 12 January 2024
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 3 (1) , 20243026
Open AccessStability and reproducibility of solid electrolyte amperometry sensors at the analysis of hydrogen in nitrogen-containing gas mixtures
This paper illustrates the results of long-term tests on the stability of the output signal of the solid electrolyte amperometry sensor when measuring the hydrogen concentration in the H2 + N2 gaseous mixture. The obtained experimental data verify the stability and reproducibility of the sensor output signal for hydrogen concentration measurements in the nitrogen-containing gaseous mixture during 8000 h of operation. The output signal drift, i.e., the limiting current value, was insignificant, less than ± 5 %. The sensor operation was performed at 3 temperature shifts with different time intervals; these changes did not have any impact either on the sensor integrity or on its operation. The structure of the solid electrolyte sensor, intermediate solid electrolyte / electrode layer and electrodes did not undergo any significant changes during operation. The dynamic characteristics of the sensor, the response time in particular, remained stable during the operation.
- Open Access
- 3 October 2023
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 2 (3) , 20232019
Sensor for operational control of oxygen and combustible gases concentration in waste gases of thermal units
A new sensor has been developed for continuous monitoring of oxygen and combustible gases content in the waste gases of thermal units. The target application of the sensor is its installation in shunt pipes of thermal units, directly into the waste gas flow. The sensor is characterized by one reference gas electrode and three measuring electrodes applied on the surface of a solid electrolyte tube made of a zirconia electrolyte (e.g., 8YSZ). The reference gas electrode and one of the measuring electrodes were made of silver, the second measuring electrode was made of platinum, the third measuring electrode was made of a mixture of zinc oxide (95 wt %) and lanthanum-strontium manganite (5 wt %). The oxygen content in the gas mixture was determined by the well-known potentiometric method in accordance with the Nernst equation, i.e. an Ag|8YSZ|Ag electrochemical cell was used. To determine the products of incomplete combustion of fuel, the method of mixed potential between Pt- and Zn-based electrodes was used; the obtained potential value was determined by the difference in the oxidation rate of carbon monoxide as the main component of unburned fuels, on different materials of measuring electrodes. The experimental results of the sensor for the determination of carbon monoxide, hydrogen, and methane in a gas mixture are presented.
- 3 October 2023
- Published by Ural Federal University in Electrochemical Materials and Technologies
- Vol. 2 (3) , 20232019
Open AccessSensor for operational control of oxygen and combustible gases concentration in waste gases of thermal units
A new sensor has been developed for continuous monitoring of oxygen and combustible gases content in the waste gases of thermal units. The target application of the sensor is its installation in shunt pipes of thermal units, directly into the waste gas flow. The sensor is characterized by one reference gas electrode and three measuring electrodes applied on the surface of a solid electrolyte tube made of a zirconia electrolyte (e.g., 8YSZ). The reference gas electrode and one of the measuring electrodes were made of silver, the second measuring electrode was made of platinum, the third measuring electrode was made of a mixture of zinc oxide (95 wt %) and lanthanum-strontium manganite (5 wt %). The oxygen content in the gas mixture was determined by the well-known potentiometric method in accordance with the Nernst equation, i.e. an Ag|8YSZ|Ag electrochemical cell was used. To determine the products of incomplete combustion of fuel, the method of mixed potential between Pt- and Zn-based electrodes was used; the obtained potential value was determined by the difference in the oxidation rate of carbon monoxide as the main component of unburned fuels, on different materials of measuring electrodes. The experimental results of the sensor for the determination of carbon monoxide, hydrogen, and methane in a gas mixture are presented.
- Open Access
- 11 May 2023
- Published by MDPI AG in Chemengineering
- Vol. 7 (3) , 45
Solid-Oxide Amperometric Sensor for Hydrogen Detection in Air
An amperometric sensor based on CaZr0.95Sc0.05O3−δ (CZS) proton-conducting oxide for the measurement of hydrogen concentration in air was designed and tested. Dense CZS ceramics were fabricated through uniaxial pressing the powder synthesized by the solid-state method and sintering at 1650 °C for 2 h. The conductivity of CZS was shown to increase with increasing air humidity, which indicates the proton type of conductivity. The sensor was made from two CZS plates, one of which had a cavity was drilled to form an inner chamber, that were then pressed against each other and sealed around the perimeter to prevent gas leaking. The inner chamber of the sensor was connected with the outer atmosphere via an alumina ceramic capillary, which acted as a diffusion barrier. The sensor performance was studied in the temperature range of 600–700 °C in the mixtures of air with hydrogen. The sensor signal, or the limiting current, was found to linearly increase with the hydrogen concentration, which simplifies the sensor calibration. The sensor demonstrated a high sensitivity of ~60 μA per 1% H2 at 700 °C, a fast response, high reproducibility, good selectivity, and long-term stability.
- 11 May 2023
- Published by MDPI AG in Chemengineering
- Vol. 7 (3) , 45
Open AccessSolid-Oxide Amperometric Sensor for Hydrogen Detection in Air
An amperometric sensor based on CaZr0.95Sc0.05O3−δ (CZS) proton-conducting oxide for the measurement of hydrogen concentration in air was designed and tested. Dense CZS ceramics were fabricated through uniaxial pressing the powder synthesized by the solid-state method and sintering at 1650 °C for 2 h. The conductivity of CZS was shown to increase with increasing air humidity, which indicates the proton type of conductivity. The sensor was made from two CZS plates, one of which had a cavity was drilled to form an inner chamber, that were then pressed against each other and sealed around the perimeter to prevent gas leaking. The inner chamber of the sensor was connected with the outer atmosphere via an alumina ceramic capillary, which acted as a diffusion barrier. The sensor performance was studied in the temperature range of 600–700 °C in the mixtures of air with hydrogen. The sensor signal, or the limiting current, was found to linearly increase with the hydrogen concentration, which simplifies the sensor calibration. The sensor demonstrated a high sensitivity of ~60 μA per 1% H2 at 700 °C, a fast response, high reproducibility, good selectivity, and long-term stability.
- Open Access
Sensor Based on a Solid Oxide Electrolyte for Measuring the Water-Vapor and Hydrogen Content in Air
The present communication describes the results of the performance and the assessment of a sensor based on a solid oxide electrolyte with a composition of 0.9ZrO2 + 0.1Y2O3 (YSZ), equipped with a ceramic diffusion barrier for measuring the water vapor and hydrogen content in air. The possibility of determining the concentration of water vapor and hydrogen in the air is based on the measurement of the limiting current value. For the calculation of the steam and hydrogen concentration in ambient air, analytical expressions were obtained and applied, using the limiting current values measured in air with a standard oxygen concentration of 20.9 vol.% and in the analyzed air. A two-stage method for the determination of the hydrogen and steam amount in ambient air is proposed. It is stated that the sensor operates successfully at the temperature of 700 °C and can be applied for the continuous determination of steam or hydrogen concentrations in air.
Open AccessSensor Based on a Solid Oxide Electrolyte for Measuring the Water-Vapor and Hydrogen Content in Air
The present communication describes the results of the performance and the assessment of a sensor based on a solid oxide electrolyte with a composition of 0.9ZrO2 + 0.1Y2O3 (YSZ), equipped with a ceramic diffusion barrier for measuring the water vapor and hydrogen content in air. The possibility of determining the concentration of water vapor and hydrogen in the air is based on the measurement of the limiting current value. For the calculation of the steam and hydrogen concentration in ambient air, analytical expressions were obtained and applied, using the limiting current values measured in air with a standard oxygen concentration of 20.9 vol.% and in the analyzed air. A two-stage method for the determination of the hydrogen and steam amount in ambient air is proposed. It is stated that the sensor operates successfully at the temperature of 700 °C and can be applied for the continuous determination of steam or hydrogen concentrations in air.
- Open Access
- 15 November 2022
- Published by Elsevier in European Journal of Medicinal Chemistry
- Vol. 245 (Pt 1) , 114935
Targeting the phosphoserine phosphatase MtSerB2 for tuberculosis drug discovery, an hybrid knowledge based /fragment based approach
- 15 November 2022
- Published by Elsevier in European Journal of Medicinal Chemistry
- Vol. 245 (Pt 1) , 114935
Open AccessTargeting the phosphoserine phosphatase MtSerB2 for tuberculosis drug discovery, an hybrid knowledge based /fragment based approach
- 1 May 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (5) , 057530
Electrochemical zirconia-based sensor for measuring hydrogen diffusion in inert gases
Solid-state electrochemical sensors represent a convenient way for solving various electroanalytical tasks. In this work, we present a comprehensive analysis of binary gases composed of hydrogen mixed with an inert gas (He, Ar, N 2 ). Using the fabricated aerometric-type YSZ-based electrolyte, diffusion coefficients for these binary gases were successfully determined in an electrochemical way in a temperature range of 550 °C–750 °C. The obtained results agree well with literature data, showing that the He+H 2 gas mixture with highly volatile components exhibit the highest diffusion coefficients, which are around 2 times higher than that for Ar+H 2 and N 2 + H 2 .
- 1 May 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (5) , 057530
Electrochemical zirconia-based sensor for measuring hydrogen diffusion in inert gases
Solid-state electrochemical sensors represent a convenient way for solving various electroanalytical tasks. In this work, we present a comprehensive analysis of binary gases composed of hydrogen mixed with an inert gas (He, Ar, N 2 ). Using the fabricated aerometric-type YSZ-based electrolyte, diffusion coefficients for these binary gases were successfully determined in an electrochemical way in a temperature range of 550 °C–750 °C. The obtained results agree well with literature data, showing that the He+H 2 gas mixture with highly volatile components exhibit the highest diffusion coefficients, which are around 2 times higher than that for Ar+H 2 and N 2 + H 2 .
- Open Access
- 29 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4515
Solid-Electrolyte Amperometric Sensor for Simultaneous Measurement of CO and CO2 in Nitrogen
A solid-state amperometric sensor based on yttria-stabilized zirconia (YSZ) for the simultaneous measurement of CO and CO2 concentrations in inert gases was fabricated. The designed sensor consists of two electrically isolated ceramic cells made of YSZ and equipped with Pt electrodes. Ceramic capillaries connecting an inner gas chamber of each cell with the outside atmosphere serve as diffusion barriers. One of the cells is intended for sensing CO, whereas the other is for sensing CO2 in the gaseous atmosphere. The electrochemical response of the sensor was studied in the temperature range of 600–750 °C in the presence of up to 10% of CO and CO2 in nitrogen. The limiting currents of the two cells were shown to rise linearly with the relevant carbon oxide concentration, and no perceptible cross-sensitivity effect toward the other carbon oxide was found. The sensor demonstrated high stability and reproducibility of results and good dynamic characteristics. The novelty of this research lies in the development of a simple, reliable and fast solid-oxide sensor for simultaneous sensing of CO and CO2 in inert gases, which can be used for the control of atmosphere in, for example, pharmaceutical, chemical, food storage industries.
- 29 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4515
Open AccessSolid-Electrolyte Amperometric Sensor for Simultaneous Measurement of CO and CO2 in Nitrogen
A solid-state amperometric sensor based on yttria-stabilized zirconia (YSZ) for the simultaneous measurement of CO and CO2 concentrations in inert gases was fabricated. The designed sensor consists of two electrically isolated ceramic cells made of YSZ and equipped with Pt electrodes. Ceramic capillaries connecting an inner gas chamber of each cell with the outside atmosphere serve as diffusion barriers. One of the cells is intended for sensing CO, whereas the other is for sensing CO2 in the gaseous atmosphere. The electrochemical response of the sensor was studied in the temperature range of 600–750 °C in the presence of up to 10% of CO and CO2 in nitrogen. The limiting currents of the two cells were shown to rise linearly with the relevant carbon oxide concentration, and no perceptible cross-sensitivity effect toward the other carbon oxide was found. The sensor demonstrated high stability and reproducibility of results and good dynamic characteristics. The novelty of this research lies in the development of a simple, reliable and fast solid-oxide sensor for simultaneous sensing of CO and CO2 in inert gases, which can be used for the control of atmosphere in, for example, pharmaceutical, chemical, food storage industries.
- 1 October 2018
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (1) , 73-79
A high-temperature electrochemical sensor based on CaZr0.95Sc0.05O3–δ for humidity analysis in oxidation atmospheres
- 1 October 2018
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 23 (1) , 73-79
A high-temperature electrochemical sensor based on CaZr0.95Sc0.05O3–δ for humidity analysis in oxidation atmospheres