Vancouver B and C periprosthetic fractures around the cemented Exeter Stem: sex is associate with fracture pattern
Open Access
- 14 August 2021
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 3221-3228
Abstract
Introduction: The aim of this study was to identify factors associated with the level of periprosthetic fracture involving a cemented polished tapered stem: Vancouver B or Vancouver C. Methods: A retrospective cohort study of 181 unilateral periprosthetic fractures involving Exeter stems was assessed by three observers (mean age 78.5, range 39–103; mean BMI 27.1, 17–39; 97 (54%) male). Patient demographics, deprivation scores, BMI and time since primary prosthesis were recorded. Femoral diameter, femoral cortical thickness, Dorr classification and distal cement mantle length were measured from calibrated radiographs. Interobserver reliability was calculated using intraclass correlation coefficients (ICCs). Univariate and multivariate analysis was performed to identify associations with Vancouver B or C fractures. Results: 160/181 (88%) Vancouver B and 21/181 (12%) Vancouver C-level fractures occurred at a mean of 5.9 ± 5.4 years (0.2–26.5) following primary surgery. Radiographic measurements demonstrated excellent agreement (ICC > 0.8, p < 0.001). Mortality was significantly higher following Vancouver C compared to B fractures: 90 day 14/160 Vs 5/21 (p = 0.05); 1 year 29/160 Vs 8/21 (p = 0.03). Univariate analysis demonstrated that Vancouver C fractures were associated with female sex, bisphosphonate use, cortical bone thickness, and distal cement mantle length (p < 0.05). On multivariate analysis, only female sex was an independent predictor of Vancouver C-level fractures (R2 =0.354, p = 0.005). Conclusion: Most PFFs involving the Exeter stem design are Vancouver B-type fractures and appear to be independent of osteoporosis. In contrast, Vancouver C periprosthetic fractures display typical fragility fracture characteristics and are associated with female sex, thinner femoral cortices, longer distal cement mantles and high mortality.Keywords
This publication has 25 references indexed in Scilit:
- Epidemiology of periprosthetic fracture of the femur in 32 644 primary total hip arthroplastiesThe Bone & Joint Journal, 2016
- Are Gender, Comorbidity, and Obesity Risk Factors for Postoperative Periprosthetic Fractures After Primary Total Hip Arthroplasty?The Journal of Arthroplasty, 2013
- Effect of cement fill ratio in loosening of hip implantsBiomatter, 2012
- A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacementInjury, 2011
- Cement mantle defects in total hip arthroplasty: influence of stem size and cementing techniqueJournal of Orthopaedics and Traumatology, 2007
- The design features of cemented femoral hip implantsThe Journal of Bone and Joint Surgery. British volume, 2006
- Three Hundred and Twenty-one Periprosthetic Femoral FracturesJournal of Bone and Joint Surgery, 2006
- Periprosthetic Femoral FracturesThe Journal of Arthroplasty, 2005
- CLASSIFICATION OF THE HIPOrthopedic Clinics of North America, 1999
- Structural and cellular assessment of bone quality of proximal femurBone, 1993