Kinematics of the Human Knee Using an Open Chain Cadaver Model
Authors:
- 1 May 2003
- journal article
- section i-symposium
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 410 (410) , 25-34
Abstract
There continues to be controversy about the kinematics of the human knee. This study used seven knees from cadavers moved by pulling on the quadriceps tendon in an open chain fashion using video motion analysis to determine the instantaneous helical axis of movement. Computed tomography scans of the specimens allowed the axes to be related to condyles. The parameter β was defined by the relationship of the helical axis to the center of the condyle (pure spinning motion) and the contact point of the condyle on the tibia (pure rolling motion). Axes above the center of the condyle represent countertranslation, those between the center and the contact point combined spinning and rolling, and those below represent concordant translation. If the motion of the knee is guided by the crossed four-bar link then this model, that allows the knee to ‘seek its own path’ throughout the range of motion, should show the rollback that commonly is thought to be an important feature of knee motion. The results of this study show that the medial side of the knee stays stable in spinning kinematics whereas the lateral side has a rolling motion in full flexion progressing to a spinning motion in midflexion and counter-translation near full extension. The kinematics that would be expected from rollback were not observed.Keywords
This publication has 10 references indexed in Scilit:
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- The Transepicondylar Axis Approximates the Optimal Flexion Axis of the KneeClinical Orthopaedics and Related Research, 1998
- In Vivo Kinematic Analysis of a Mobile Bearing Total Knee ProsthesisClinical Orthopaedics and Related Research, 1997
- The Axes of Rotation of the KneeClinical Orthopaedics and Related Research, 1993
- Differentiation of Human Motion Data Using Combined Spline and Least Squares ConceptsJournal of Biomechanical Engineering, 1991
- Helical axes of passive knee joint motionsJournal of Biomechanics, 1990
- The envelope of passive knee joint motionJournal of Biomechanics, 1988
- Geometry and motion of the knee for implant and orthotic designJournal of Biomechanics, 1985
- Roentgen stereophotogrammetric methods for the evaluation of the three dimensional kinematic behaviour and cruciate ligament length patterns of the human knee jointJournal of Biomechanics, 1979
- The mechanics of the knee and prosthesis designThe Journal of Bone and Joint Surgery. British volume, 1978