John David Blaha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John David Blaha has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Corrie A. Mancinelli
Division of Physical Therapy, Department of Human Performance and Applied Exercise Science, West Virginia University, P.O. Box 9226, Morgantown, WV 26506-9226
2 shared publicationsHiroyuki Kawashima
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
2 shared publicationsOsamu Tanifuji
Division of Orthopaedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
2 shared publicationsShigeru Takagi
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
2 shared publicationsShin Kai
Center for Fostering Innovative Leadership, Institute for Research Collaboration and Promotion, Niigata University, Niigata, Japan
2 shared publicationsTomoharu Mochizuki
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Graduate School of Medical and Dental Sciences, Niigata University, Niigata, Japan
2 shared publications
Latest Publications
- 15 March 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (7) , S381-S384
The Quadriceps Vector in the Lower Extremity of Indian Patients Is Similar in Caucasian and Japanese Patients
- 15 March 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (7) , S381-S384
The Quadriceps Vector in the Lower Extremity of Indian Patients Is Similar in Caucasian and Japanese Patients
- 21 March 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (6) , S284-S289
Medial-Pivot Design Improved Knee Symptoms From Anteroposterior Instability in Early-Range Flexion and Resolved Anterior Knee Pain in Revision Total Knee Arthroplasty
- 21 March 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (6) , S284-S289
Medial-Pivot Design Improved Knee Symptoms From Anteroposterior Instability in Early-Range Flexion and Resolved Anterior Knee Pain in Revision Total Knee Arthroplasty
- 16 June 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (12) , e49
Bone Strength and Viscoelasticity Affect Cementless Femoral Stem Fixation
- 16 June 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (12) , e49
Bone Strength and Viscoelasticity Affect Cementless Femoral Stem Fixation
- 7 October 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (19) , e112
Protecting the Short External Rotators: Essential for Function and Easily Damaged
- 7 October 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (19) , e112
Protecting the Short External Rotators: Essential for Function and Easily Damaged
- 1 March 2013
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (3) , 1014-1020
The Vector of Quadriceps Pull is Directed From the Patella to the Femoral Neck
The quadriceps is the primary extensor of the knee. Its vector, which is perpendicular to the flexion axis of the knee, is important in understanding knee function and properly aligning total knee components. Three-dimensional (3-D) imaging enables evaluation using a 3-D model of each quadriceps component. We calculated the direction and magnitude of the quadriceps vector (QV) and the precision of the measurement, and asked whether the QV bears a constant relationship to the femur and is aligned with an anatomically based axis on the femur. Using CT data of 14 subjects, we created a 3-D solid model of each quadriceps muscle component. Vectors (3-D direction and length) for each quadriceps component were determined using principal component analysis for muscle direction and volume for magnitude; vector addition established the directional vector of the combined muscle. The combined vector originating in the center of the patella was compared with the shaft, mechanical, and spherical (center femoral head to center medial side of the knee) axes. The QV passed from the patella center proximally crossing the femoral neck between the femoral head and greater trochanter and was most closely aligned with the spherical axis. The QV axis may be an important reference for alignment of total knee components. The spherical axis can be used in aligning total knee components to the flexion axis of the knee.
- 1 March 2013
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 471 (3) , 1014-1020
The Vector of Quadriceps Pull is Directed From the Patella to the Femoral Neck
The quadriceps is the primary extensor of the knee. Its vector, which is perpendicular to the flexion axis of the knee, is important in understanding knee function and properly aligning total knee components. Three-dimensional (3-D) imaging enables evaluation using a 3-D model of each quadriceps component. We calculated the direction and magnitude of the quadriceps vector (QV) and the precision of the measurement, and asked whether the QV bears a constant relationship to the femur and is aligned with an anatomically based axis on the femur. Using CT data of 14 subjects, we created a 3-D solid model of each quadriceps muscle component. Vectors (3-D direction and length) for each quadriceps component were determined using principal component analysis for muscle direction and volume for magnitude; vector addition established the directional vector of the combined muscle. The combined vector originating in the center of the patella was compared with the shaft, mechanical, and spherical (center femoral head to center medial side of the knee) axes. The QV passed from the patella center proximally crossing the femoral neck between the femoral head and greater trochanter and was most closely aligned with the spherical axis. The QV axis may be an important reference for alignment of total knee components. The spherical axis can be used in aligning total knee components to the flexion axis of the knee.
- 1 November 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (Supplement) , 19-22
Failure of Sex to Predict the Size and Shape of the Knee
Proponents of this technology have identified three anatomical differences in the female knee: a smaller anterior condyle, an increased quadriceps angle (Q angle), and a reduced medial-lateral to anterior-posterior aspect ratio2,3. The evidence supporting these claims has recently been scrutinized by Merchant et al.4, who concluded that there appear to be no meaningful anatomical differences between male and female knees. Furthermore, they found no evidence that women have worse outcomes than men after traditional total knee arthroplasty, a conclusion that calls into question the need for sex-specific implants. In fact, women do equally well or, in some cases, better than men do4. The ideas regarding the need for a sex-specific implant have largely been introduced into the literature by representatives of the companies most associated with marketing the concept4.
- 1 November 2009
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (Supplement) , 19-22
Failure of Sex to Predict the Size and Shape of the Knee
Proponents of this technology have identified three anatomical differences in the female knee: a smaller anterior condyle, an increased quadriceps angle (Q angle), and a reduced medial-lateral to anterior-posterior aspect ratio2,3. The evidence supporting these claims has recently been scrutinized by Merchant et al.4, who concluded that there appear to be no meaningful anatomical differences between male and female knees. Furthermore, they found no evidence that women have worse outcomes than men after traditional total knee arthroplasty, a conclusion that calls into question the need for sex-specific implants. In fact, women do equally well or, in some cases, better than men do4. The ideas regarding the need for a sex-specific implant have largely been introduced into the literature by representatives of the companies most associated with marketing the concept4.
- 1 May 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 410 (410) , 25-34
Kinematics of the Human Knee Using an Open Chain Cadaver Model
There continues to be controversy about the kinematics of the human knee. This study used seven knees from cadavers moved by pulling on the quadriceps tendon in an open chain fashion using video motion analysis to determine the instantaneous helical axis of movement. Computed tomography scans of the specimens allowed the axes to be related to condyles. The parameter β was defined by the relationship of the helical axis to the center of the condyle (pure spinning motion) and the contact point of the condyle on the tibia (pure rolling motion). Axes above the center of the condyle represent countertranslation, those between the center and the contact point combined spinning and rolling, and those below represent concordant translation. If the motion of the knee is guided by the crossed four-bar link then this model, that allows the knee to ‘seek its own path’ throughout the range of motion, should show the rollback that commonly is thought to be an important feature of knee motion. The results of this study show that the medial side of the knee stays stable in spinning kinematics whereas the lateral side has a rolling motion in full flexion progressing to a spinning motion in midflexion and counter-translation near full extension. The kinematics that would be expected from rollback were not observed.
- 1 May 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 410 (410) , 25-34
Kinematics of the Human Knee Using an Open Chain Cadaver Model
There continues to be controversy about the kinematics of the human knee. This study used seven knees from cadavers moved by pulling on the quadriceps tendon in an open chain fashion using video motion analysis to determine the instantaneous helical axis of movement. Computed tomography scans of the specimens allowed the axes to be related to condyles. The parameter β was defined by the relationship of the helical axis to the center of the condyle (pure spinning motion) and the contact point of the condyle on the tibia (pure rolling motion). Axes above the center of the condyle represent countertranslation, those between the center and the contact point combined spinning and rolling, and those below represent concordant translation. If the motion of the knee is guided by the crossed four-bar link then this model, that allows the knee to ‘seek its own path’ throughout the range of motion, should show the rollback that commonly is thought to be an important feature of knee motion. The results of this study show that the medial side of the knee stays stable in spinning kinematics whereas the lateral side has a rolling motion in full flexion progressing to a spinning motion in midflexion and counter-translation near full extension. The kinematics that would be expected from rollback were not observed.