Abstract
In order to solve the problem that the output voltage of bilateral LC-compensated CPT system varies with the variation of load and equivalent coupling capacitance, this paper presented a parameter design method which maintained the output voltage constant and guaranteed a high power factor. The mathematical model of the bilateral LC-compensated CPT system was established. The characteristic of the primary and secondary LC-compensated network were analysed, then the conditions remaining a constant output voltage with varying load and coupling capacitance were determined. The relationship between the power factor and the load versus equivalent coupling capacitance was given. With the proposed parameter design method, a 100 W bilateral LC-compensated CPT experimental setup was constructed. The output voltage changes from 55.0 V to 58.7 V and the power factor varies from 0.902 to 0.977, when the load and coupling capacitance vary from 30.2 Ω to 70.8 Ω and from 310 pF to 1490 pF respectively. Both simulation and experimental results have verified the characteristic of constant output voltage and the effectiveness of the proposed parameter design method.
Funding Information
  • National Key R&D Program of China (2018YFB0106300)

This publication has 22 references indexed in Scilit: