XWXueying Wu

Xueying Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xueying Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Hybrid Wireless Power Transfer System With Constant and Enhanced Current Output Against Load Variation and Coupling Misalignment

    by Xiaodong Qing, Zuojin Li, Xueying Wu, Zhe Liu, Lei Zhao, Yugang Su

    Inductive power transfer and capacitive power transfer (CPT) are two of the most commonly used near-field wireless power transfer technologies, and these two systems share similarities and symmetries. This article proposes a hybrid wireless power transfer (HWPT) system to achieve load-independent characteristic and anti-misalignment capability. The HWPT system utilizes the compensation inductors of the CPT system to create an additional inductive channel in which the capacitive and inductive channels are compensated for each other. Based on the modeling of the HWPT system, the load-independent and enhanced constant current output is derived. In HWPT system, the inductive coupler is employed with the capacitive coupler, which forms a compact hybrid coupler. As the coupler becomes misaligned, the loss of power transferred through the inductive channel can be compensated by the increase of power transferred through the capacitive channel. A 200 W experimental prototype is built to validate the performance of the HWPT system. Experimental results show that as the load resistance ranges from 20 to 40 $\Omega$ and the coupling misalignment ranges from 0 to 100 mm, the output current remains nearly constant and the input current stays in phase with the input voltage. According to the experimental findings, the output current of the HWPT system is approximately twice as high as that of the CPT system when using the same capacitive coupler.


  • A Reticulated Planar Transmitter Using a Three-Dimensional Rotating Magnetic Field for Free-Positioning Omnidirectional Wireless Power Transfer

    by Tianxu Feng, Zhiping Zuo, Yue Sun, Xin Dai, Xueying Wu, Lujing Zhu

    This article proposes a free-positioning omnidirectional wireless power transfer (WPT) system with a reticulated planar transmitter, which enables multiple receivers to be powered simultaneously in arbitrary positions and orientations. The reticulated planar transmitter is equipped with four interleaved and overlapped meander coils, thus, a three-dimensional (3-D) rotating magnetic field is generated with the designed excitation current. Therefore, only a planar single-coil (such as a loop-type coil) is required to realize free-positioning omnidirectional WPT. According to the theoretical modeling of the magnetic field, the excitation current that can generate a 3-D rotating magnetic field is given. To obtain a uniform and strong magnetic field distribution, the transmitter grid width is optimized. Furthermore, an excitation current modulation strategy based on phase-shift control is presented to regulate the amplitude of the excitation current. The experimental results show that the output power is greater than 13.1 W no matter how the center of the receiver moves or rotates freely within 400 × 400 mm. When five receivers are powered simultaneously in different positions and orientations, 82.5 W total output power and 55.6% efficiency can be achieved. The experimental results demonstrate that free-positioning omnidirectional WPT can be realized with only planar single-coil receivers by using the proposed reticulated planar transmitter and its excitation current modulation strategy.


  • Multiobjective Parameter Optimization of a Four-Plate Capacitive Power Transfer System

    by Xueying Wu, Yugang Su, Aiguo Patrick Hu, Xiaodong Qing, Xinyu Hou

    For a four-plate capacitive power transfer (CPT) system, the existing coupling and compensation design methods can only provide an approximate local parameter optimization solution, instead of a globally optimized solution. This paper proposes an accurate calculation method for cross-coupling capacitance and a multi-objective optimization algorithm combining non-dominated sorting and Kent map for an SS-type CPT system. Mathematical models of the cross-coupling capacitances and port capacitances are established based on a two-port capacitive coupling model of the four plates. Besides, the constraints considering the reasonable region of the parameter values are given. Taking the output power, efficiency and total harmonic distortion (THD) as objective functions, with the power transfer distance, operating frequency, load resistance, and input voltage as decision variables, the Pareto-optimal fronts are obtained by the proposed algorithm. A group of global optimal parameters are chosen from the solution sets, and a simulation model and a prototype of the CPT system are constructed. Efficiency of 87.1% at 252.3W output power has been achieved. The simulation and experimental results verified the feasibility and effectiveness of the proposed calculating method for the cross-coupling capacitance and optimization method.


  • Parameter Design Method With Constant Output Voltage Characteristic for Bilateral LC-Compensated CPT System

    by Xiao-Dong Qing, Zhi-Hui Wang, Yu-Gang Su, Yu-Ming Zhao, Xue-Ying Wu

    In order to solve the problem that the output voltage of bilateral LC-compensated CPT system varies with the variation of load and equivalent coupling capacitance, this paper presented a parameter design method which maintained the output voltage constant and guaranteed a high power factor. The mathematical model of the bilateral LC-compensated CPT system was established. The characteristic of the primary and secondary LC-compensated network were analysed, then the conditions remaining a constant output voltage with varying load and coupling capacitance were determined. The relationship between the power factor and the load versus equivalent coupling capacitance was given. With the proposed parameter design method, a 100 W bilateral LC-compensated CPT experimental setup was constructed. The output voltage changes from 55.0 V to 58.7 V and the power factor varies from 0.902 to 0.977, when the load and coupling capacitance vary from 30.2 Ω to 70.8 Ω and from 310 pF to 1490 pF respectively. Both simulation and experimental results have verified the characteristic of constant output voltage and the effectiveness of the proposed parameter design method.