Real-time communication of head velocity and acceleration for an externally mounted vestibular prosthesis
- 1 August 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 3537-3541
Abstract
Loss of vestibular function results in imbalance, disorientation, and oscillopsia. Several groups have designed and constructed implantable devices to restore vestibular function through electrical stimulation of the vestibular nerve. We have designed a two-part device in which the head motion sensing and signal processing elements are externally mounted to the head, and are coupled through an inductive link to a receiver stimulator that is based on a cochlear implant. The implanted electrode arrays are designed to preserve rotational sensitivity in the implanted ear. We have tested the device in rhesus monkeys by rotating the animals in the plane of the implanted canals, and then using head velocity and acceleration signals to drive electrical stimulation of the vestibular system. Combined electrical and rotational stimulation results in a summation of responses, so that one can control the modulation of eye velocity induced by sinusoidal yaw rotation.Keywords
This publication has 19 references indexed in Scilit:
- Virtual labyrinth model of vestibular afferent excitation via implanted electrodes: validation and application to design of a multichannel vestibular prosthesisExperimental Brain Research, 2011
- Cross-axis adaptation improves 3D vestibulo-ocular reflex alignment during chronic stimulation via a head-mounted multichannel vestibular prosthesisExperimental Brain Research, 2011
- Eye Movements in Response to Electrical Stimulation of the Lateral and Superior Ampullary NervesAnnals of Otology, Rhinology & Laryngology, 2011
- Vestibuloocular Reflex Adaptation Investigated With Chronic Motion-Modulated Electrical Stimulation of Semicircular Canal AfferentsJournal of Neurophysiology, 2010
- Vestibulo-Ocular Responses Evoked Via Bilateral Electrical Stimulation of the Lateral Semicircular CanalsIEEE Transactions on Biomedical Engineering, 2008
- Chronic Vestibulo-Ocular Reflexes Evoked by a Vestibular ProsthesisIEEE Transactions on Biomedical Engineering, 2007
- Acclimation to Chronic Constant-Rate Peripheral Stimulation Provided by a Vestibular ProsthesisIEEE Transactions on Biomedical Engineering, 2006
- System design and performance of a unilateral horizontal semicircular canal prosthesisIEEE Transactions on Biomedical Engineering, 2002
- Prototype Neural Semicircular Canal Prosthesis using Patterned Electrical StimulationAnnals of Biomedical Engineering, 2000
- Implantation of magnetic search coils for measurement of eye position: An improved methodVision Research, 1980