JPJames O. Phillips

James O. Phillips

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James O. Phillips has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Jay T. Rubinstein

    Department of Otolaryngology-HNS, University of Washington, Seattle, Washington; Department of Bioengineering, University of Washington, Seattle, Washington; National Primate Research Center, University of Washington, Seattle, Washington; and Virginia Merrill Bloedel Hearing Research Center, University of Washington, Seattle, Washington

    3 shared publications
  • Kaibao Nie

    Department of Otolaryngology-HNS, University of Washington, Seattle, Washington; Virginia Merrill Bloedel Hearing Research Center, University of Washington, Seattle, Washington

    3 shared publications
  • Leo Ling

    Department of Otolaryngology-HNS, University of Washington, Seattle, Washington; National Primate Research Center, University of Washington, Seattle, Washington; and

    3 shared publications
  • Amy L. Nowack

    Department of Otolaryngology-HNS, University of Washington, Seattle, Washington; National Primate Research Center, University of Washington, Seattle, Washington; and

    2 shared publications
  • Steven M. Bierer

    Department of Speech and Hearing Sciences at the University of Washington, Seattle, 98195, USA

    2 shared publications
  • Chris R.S. Kaneko

    Department of Physiology and Biophysics at the University of Washington, Seattle, 98195, USA

    1 shared publication

Latest Publications

  • Vestibular implantation and longitudinal electrical stimulation of the semicircular canal afferents in human subjects

    by James O. Phillips, Leo Ling, Kaibao Nie, Elyse Jameyson, Christopher M. Phillips, Amy L. Nowack, Justin S. Golub, Jay T. Rubinstein

    Animal experiments and limited data in humans suggest that electrical stimulation of the vestibular end organs could be used to treat loss of vestibular function. In this paper we demonstrate that canal-specific two-dimensionally (2D) measured eye velocities are elicited from intermittent brief 2 s biphasic pulse electrical stimulation in four human subjects implanted with a vestibular prosthesis. The 2D measured direction of the slow phase eye movements changed with the canal stimulated. Increasing pulse current over a 0–400 μA range typically produced a monotonic increase in slow phase eye velocity. The responses decremented or in some cases fluctuated over time in most implanted canals but could be partially restored by changing the return path of the stimulation current. Implantation of the device in Meniere's patients produced hearing and vestibular loss in the implanted ear. Electrical stimulation was well tolerated, producing no sensation of pain, nausea, or auditory percept with stimulation that elicited robust eye movements. There were changes in slow phase eye velocity with current and over time, and changes in electrically evoked compound action potentials produced by stimulation and recorded with the implanted device. Perceived rotation in subjects was consistent with the slow phase eye movements in direction and scaled with stimulation current in magnitude. These results suggest that electrical stimulation of the vestibular end organ in human subjects provided controlled vestibular inputs over time, but in Meniere's patients this apparently came at the cost of hearing and vestibular function in the implanted ear.


  • Longitudinal performance of a vestibular prosthesis as assessed by electrically evoked compound action potential recording

    by James O. Phillips, Sarah J. Shepherd, Amy L. Nowack, Leo Ling, Steven M. Bierer, Chris R.S. Kaneko, Christopher M.T. Phillips, Kaibao Nie, Jay T. Rubinstein

    Electrical stimulation of the vestibular end organ with a vestibular prosthesis may provide an effective treatment for vestibular loss if the stimulation remains effective over a significant period of time after implantation of the device. To assess efficacy of electrical stimulation in an animal model, we implanted 3 rhesus monkeys with a vestibular prosthesis based on a cochlear implant. We then recorded vestibular electrically evoked compound action potentials (vECAPs) longitudinally in each of the implanted canals to see how the amplitude of the response changed over time. The results suggest that vECAPs, and therefore electrical activation of vestibular afferent fibers, can remain largely stable over time following implantation.


  • Real-time communication of head velocity and acceleration for an externally mounted vestibular prosthesis

    by James O. Phillips, Steven M. Bierer, Leo Ling, Kaibao Nie, Jay T. Rubinstein

    Loss of vestibular function results in imbalance, disorientation, and oscillopsia. Several groups have designed and constructed implantable devices to restore vestibular function through electrical stimulation of the vestibular nerve. We have designed a two-part device in which the head motion sensing and signal processing elements are externally mounted to the head, and are coupled through an inductive link to a receiver stimulator that is based on a cochlear implant. The implanted electrode arrays are designed to preserve rotational sensitivity in the implanted ear. We have tested the device in rhesus monkeys by rotating the animals in the plane of the implanted canals, and then using head velocity and acceleration signals to drive electrical stimulation of the vestibular system. Combined electrical and rotational stimulation results in a summation of responses, so that one can control the modulation of eye velocity induced by sinusoidal yaw rotation.