Non-Contact Short-Term Heart Rate Variability Analysis Under Paced Respiration Based on a Robust Fiber Optic Sensor System
- 9 January 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Abstract
In this article, a low-cost fiber optic sensor (FOS)-based system is proposed for the long-term stable measurement of ballistocardiography (BCG), which can be used to analyze short-term heart rate variability (HRV). The core part of the system is a single-mode fiber-based Mach–Zehnder interferometer (MZI), which consists of a $1\times2$ coupler and a $3\times3$ coupler. Due to the asymmetric structure of the two MZI arms, the interference spectrum will be observed, which will move linearly with the change of the transverse stress. The incident light is emitted from a low-cost distributed feedback (DFB) laser and coupled into the MZI sensor. The vibrations induced by human respiration and heartbeat will result in the variation of light phase in MZI, and further give rise to the change of interfering light intensity, which is detected by three photodetectors (PDs). The FOS-based BCG interbeat interval (IBI) shows high correlations with electrocardiography (ECG)-derived IBI, with correlation coefficients of 0.9971 and 0.9581 for healthy and premature beats subjects, respectively. During the one-month stability test, the FOS-based BCG monitoring system realized high accuracy. An inverse relationship between BCG-derived HRV amplitude and respiratory rate is revealed in this study. In this work, we also discover the phenomenon that breathing at 0.1 Hz causes larger respiratory sinus arrhythmia (RSA) amplitude, and resonant frequency breathing is observed in BCG-derived IBI signals. In addition, the time-domain, frequency-domain, and nonlinear analysis results of BCG HRV and ECG HRV at 0.1 and 0.25 Hz respiratory rates are highly correlated. In addition to high accuracy, the FOS-based BCG monitoring system has the unique advantage of flexible configuration to obtain continuous and accurate HR information without contact. This system has the potential to become a preferred alternative for ECG in daily monitoring.Keywords
Funding Information
- Shenzhen Municipal Science and Technology Innovation Commission (Shenzhen-HK-Macao Science and Technology Plan C SGDX2020110309520303 K-ZGCQ)
- Hong Kong Polytechnic University (HKPU 1-WZ01)
This publication has 44 references indexed in Scilit:
- Heart rate variability and slow-paced breathing:when coherence meets resonanceNeuroscience & Biobehavioral Reviews, 2022
- A camera-based ballistocardiogram heart rate measurement methodReview of Scientific Instruments, 2020
- Poincaré plot indices as measures of sympathetic cardiac regulation: Responses to psychological stress and associations with pre-ejection periodInternational Journal of Psychophysiology, 2018
- Reminder: RMSSD and SD1 are identical heart rate variability metricsMuscle & Nerve, 2017
- The variable heart: High frequency and very low frequency correlates of depressive symptoms in children and adolescentsJournal of Affective Disorders, 2015
- Acute mental stress assessment via short term HRV analysis in healthy adults: A systematic review with meta-analysisBiomedical Signal Processing and Control, 2015
- Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensorMedical & Biological Engineering & Computing, 2011
- Occupational exposure to noise and the cardiovascular system: A meta-analysisScience of The Total Environment, 2010
- Increased non-stationarity of heart rate during general anaesthesia with sevoflurane or desflurane in childrenBritish Journal of Anaesthesia, 2008
- Combining classical HRV indices with wavelet entropy measures improves to performance in diagnosing congestive heart failureComputers in Biology and Medicine, 2007