  • Contactless Arrhythmia Detection and Short-Term HRV Analysis Based on a Fiber Optic Sensor

    by Weimin Lyu, Tianyu Chen, Shuyang Chen, Weihao Yuan, Yujian Li, Qing Wang, Changyuan Yu

    Accurate detection of premature atrial contractions (PACs) is crucial for identifying life-threatening arrhythmias. Traditional electrocardiogram (ECG) devices, which require electrodes attached to the body, often cause discomfort and are unsuitable for long-term monitoring. This paper presents a non-contact ballistocardiogram (BCG) monitoring system utilizing a fiber optic sensor (FOS) for PAC identification and short-term heart rate variability (HRV) analysis. The system employs a Mach-Zehnder interferometer (MZI), which is simple and easy to replicate, consisting of only a 1×2 coupler and a 3×3 coupler. Tiny body vibrations caused by breathing and heartbeats lead to changes in the intensity of the interference light. By detecting these changes using three photodetectors (PDs), vital sign signals can be captured. To evaluate the robustness of the PAC detection algorithm, the study introduced fixed-speed breathing at two respiratory frequencies, increasing the range of interbeat interval (IBI) variations. The correlation coefficient between BCG-derived IBI and ECG-derived IBI in subjects with PAC was 0.9475. The proposed algorithm achieved an accuracy of 94.84% in PAC detection. Additionally, the time-domain and frequency-domain results of BCG-derived HRV and ECG-derived HRV showed high correlation at respiratory rates of 6 beats per minute (bpm) and 15 bpm. The FOS-based BCG signal not only accurately identifies PACs but also facilitates HRV analysis. This proposed system is suitable for long-term, non-contact vital sign monitoring in daily life.


  • A Real-Time Sleep Monitoring System Based on Fiber Optic Sensor

    by Tianyu Chen, Weimin Lyu, Shuyang Chen, Changyuan Yu

    This study introduces a real-time sleep monitoring system using optical fiber sensors and threshold-based turnover detection, enabling non-invasive extraction of heart and respiratory rates with high accuracy for clinical and home environments.


  • Non-Contact Short-Term Heart Rate Variability Analysis Under Paced Respiration Based on a Robust Fiber Optic Sensor System

    by Weimin Lyu, Weihao Yuan, Jianxun Yu, Qing Wang, Shuyang Chen, Jing Qin, Changyuan Yu

    In this article, a low-cost fiber optic sensor (FOS)-based system is proposed for the long-term stable measurement of ballistocardiography (BCG), which can be used to analyze short-term heart rate variability (HRV). The core part of the system is a single-mode fiber-based Mach–Zehnder interferometer (MZI), which consists of a $1\times2$ coupler and a $3\times3$ coupler. Due to the asymmetric structure of the two MZI arms, the interference spectrum will be observed, which will move linearly with the change of the transverse stress. The incident light is emitted from a low-cost distributed feedback (DFB) laser and coupled into the MZI sensor. The vibrations induced by human respiration and heartbeat will result in the variation of light phase in MZI, and further give rise to the change of interfering light intensity, which is detected by three photodetectors (PDs). The FOS-based BCG interbeat interval (IBI) shows high correlations with electrocardiography (ECG)-derived IBI, with correlation coefficients of 0.9971 and 0.9581 for healthy and premature beats subjects, respectively. During the one-month stability test, the FOS-based BCG monitoring system realized high accuracy. An inverse relationship between BCG-derived HRV amplitude and respiratory rate is revealed in this study. In this work, we also discover the phenomenon that breathing at 0.1 Hz causes larger respiratory sinus arrhythmia (RSA) amplitude, and resonant frequency breathing is observed in BCG-derived IBI signals. In addition, the time-domain, frequency-domain, and nonlinear analysis results of BCG HRV and ECG HRV at 0.1 and 0.25 Hz respiratory rates are highly correlated. In addition to high accuracy, the FOS-based BCG monitoring system has the unique advantage of flexible configuration to obtain continuous and accurate HR information without contact. This system has the potential to become a preferred alternative for ECG in daily monitoring.


  • Compressed sensing framework for BCG signals based on the optical fiber sensor

    by Shuyang Chen, Huaijian Luo, Weimin Lyu, Jianxun Yu, Jing Qin, Changyuan Yu

    A compressed sensing (CS) framework is built for ballistocardiography (BCG) signals, which contains two parts of an optical fiber sensor-based heart monitoring system with a CS module and an end-to-end deep learning-based reconstruction algorithm. The heart monitoring system collects BCG data, and then compresses and transmits the data through the CS module at the sensing end. The deep learning-based algorithm reconstructs compressed data at the received end. To evaluate results, three traditional CS reconstruction algorithms and a deep learning method are adopted as references to reconstruct the compressed BCG data with different compression ratios (CRs). Results show that our framework can reconstruct signals successfully when the CR grows from 50% to 95% and outperforms other methods at high CRs. The mean absolute error (MAE) of the estimated heartbeat rate (HR) is lower than 1 bpm when the CR is below 95%. The proposed CS framework for BCG signals can be integrated into the IoMT system, which has great potential in health care for both medical and home use.


  • Deep learning-based ballistocardiography reconstruction algorithm on the optical fiber sensor

    by Shuyang Chen, Fengze Tan, Weimin Lyu, Huaijian Luo, Jianxun Yu, Jiaqi Qu, Changyuan Yu

    Ballistocardiography (BCG) is a vibration signal related to cardiac activity, which can be obtained in a non-invasive way by optical fiber sensors. In this paper, we propose a modified generative adversarial network (GAN) to reconstruct BCG signals by solving signal fading problems in a Mach-Zehnder interferometer (MZI). Based on this algorithm, additional modulators and demodulators are not needed in the MZI, which reduces the cost and hardware complexity. The correlation between reconstructed BCG and reference BCG is 0.952 in test data. To further test the model performance, we collect special BCG signals including sinus arrhythmia data and post-exercise cardiac activities data, and analyze the reconstructed results. In conclusion, a BCG reconstruction algorithm is presented to solve the signal fading problem in the optical fiber interferometer innovatively, which greatly simplifies the BCG monitoring system.


  • Open Access

    Vital Signs Monitoring Based on Interferometric Fiber Optic Sensors

    by Weimin Lyu, Shuyang Chen, Fengze Tan, Changyuan Yu

    Due to the improvement of living standards, people’s attention to health has gradually increased. More and more people are willing to spend money and time on health management. This article reviews work on the vital signs monitoring system based on fiber optic interferometers, including the design of sensor structures, signal demodulation methods and data analysis. After a large number of trials, the system can achieve long-term stable heart rate (HR), respiration rate (RR) and body temperature monitoring, and the collected data can be used for health analysis. Due to the high sensitivity, low cost, and light weight of the interferometric fiber optic sensor, it can be integrated under a mattress or a cushion, which is very suitable for daily use. The system has great application prospects in the field of healthcare.


  • Non-Invasive Measurement for Cardiac Variations Using a Fiber Optic Sensor

    by Weimin Lyu, Wei Xu, Fangang Yang, Shuyang Chen, Fengze Tan, Changyuan Yu

    Cardiovascular diseases (CVDs) are very common in modern society, such as atherosclerosis, hypertension, etc., which have a great impact on heart function. Therefore, hospitalization monitoring alone is far from enough. Long-term monitoring of the heart is needed in daily life. The technology of non-invasive monitoring of the cardiovascular system can meet the needs of long-term monitoring of the heart condition, helping to promote the improvement of lifestyle and daily care, reducing the overall risk of developing CVDs. The purpose of this study is to investigate the cardiac response after different exercises using a $3\times 3$ demodulation scheme-based ballistocardiography (BCG) monitoring system. A fiber optic sensor (FOS)-based smart cushion is used to replace the traditional inconvenient electrocardiogram (ECG) for heart rate variability (HRV). The correlation between BCG inter-beat interval (IBI) and ECG IBI is 0.9862, and the RMSE is 0.0139. The BCG signal can assess cardiac contractility by analyzing RJ interval with ECG, which is a practical alternative to the pre-ejection period (PEP).


  • Ballistocardiography monitoring system based on optical fiber interferometer aided with heartbeat segmentation algorithm

    by Shuyang Chen, Fengze Tan, Weimin Lyu, Changyuan Yu

    An optical fiber interferometer-based ballistocardiography (BCG) monitoring system aided with the IJK complex detection algorithm is proposed in this paper. A new phase modulation method based on a moving-coil transducer is developed to address the problem of signal fading in the optical fiber interferometer and keep the system in quadrature by the closed loop controller. As a result, a stable BCG signal without baseline drift can be obtained. This BCG monitor based on optical fiber interferometer using phase modulation method owns the advantages of compact, low-cost, portable, and user-friendly. In addition, an end-to-end modified U-net is developed to conduct pixel-wise classification in the BCG signal. This network can achieve high accuracy and shows its capability to segment IJK complex and body movement in the BCG signal. In conclusion, the proposed BCG monitoring system with IJK complex segmentation algorithm is potential and promising in healthcare applications.