Routine high‐precision analysis of triple water‐isotope ratios using cavity ring‐down spectroscopy
- 14 August 2016
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 30 (18) , 2059-2069
Abstract
Rationale: Water isotope analysis for δ 2 H and δ 18 O values via laser spectroscopy is routine for many laboratories. While recent work has added the δ 17 O value to the high‐precision suite, it does not follow that researchers will routinely obtain high precision 17 O excess ( Δ 17 O). We demonstrate the routine acquisition of high‐precision δ 2 H, δ 17 O, δ 18 O, d , and Δ 17 O values using a commercially available laser spectroscopy instrument. Methods: We use a Picarro L2140‐ i cavity ring‐down spectroscopy analyzer with discrete liquid injections into an A0211 vaporization module by a Leap Technologies LC PAL autosampler. The instrument is run in two modes: (1) as recommended by the manufacturer (default mode) and (2) after modifying select default settings and using alternative data types (advanced mode). Reference waters analyzed over the course of 15 months while running unknown samples are used to assess system performance. Results: The default mode provides precision for δ 2 H, δ 17 O, δ 18 O, d , and Δ 17 O values that may be sufficient for many applications. When using the advanced mode, we reach a higher level of precision for δ 2 H, δ 17 O, δ 18 O, d , and Δ 17 O values (0.4 mUr, 0.04 mUr, 0.07 mUr, 0.5 mUr, and 8 μUr, respectively, where mUr = 0.001 = ‰, and μUr = 10 –6 ) in a shorter amount of time and with fewer syringe actuations than in the default mode. The improved performance results from an increase in the total integration time for each injected water pulse. Conclusions: Our recommended approach for routine δ 2 H, δ 17 O, δ 18 O, d and Δ 17 O measurements with the Picarro L2140‐ i is to make use of conditioning vials, use fewer injections (5 per vial) with greater pulse duration (520 seconds (s) per injection) and use only the first 120 s for δ 2 H measurements and all 520 s for δ 17 O and δ 18 O measurements. Although the sample throughput is 10 unknowns per day, our optimal approach reduces the number of syringe actuations, the effect of memory, and the total analysis time, while improving precision relative to the default approach. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
This publication has 35 references indexed in Scilit:
- Improved water δ 2 H and δ 18 O calibration and calculation of measurement uncertainty using a simple software toolRapid Communications in Mass Spectrometry, 2011
- Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS)Rapid Communications in Mass Spectrometry, 2011
- A continuous stream flash evaporator for the calibration of an IR cavity ring-down spectrometer for the isotopic analysis of waterIsotopes in Environmental and Health Studies, 2010
- Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil watersRapid Communications in Mass Spectrometry, 2010
- High-Precision Laser Spectroscopy D/H and 18O/16O Measurements of Microliter Natural Water SamplesAnalytical Chemistry, 2007
- Normalization of measured stable isotopic compositions to isotope reference scales – a reviewRapid Communications in Mass Spectrometry, 2007
- Isotope Ratio Infrared Spectrometry2004
- Measuring stable isotopes of hydrogen and oxygen in ice by means of laser spectrometry: the Bølling transition in the Dye-3 (south Greenland) ice coreAnnals of Glaciology, 2002
- Simultaneous Determination of the2H/1H,17O/16O, and18O/16O Isotope Abundance Ratios in Water by Means of Laser SpectrometryAnalytical Chemistry, 1999
- Oxygen Exchange Reactions of Organic Compounds and WaterJournal of the American Chemical Society, 1938