Ocular higher-order aberrations in myopia and skiascopic wavefront repeatability
- 1 June 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (6) , 1128-1132
Abstract
To study the distribution of ocular higher-order aberrations (HOAs) in a myopic population and to assess the repeatability of HOA measurements determined by a commercially available skiascopic wavefront sensor. Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel. Ocular HOAs were examined 3 times across a 6.0 mm naturally dilated pupil in 61 eyes using the Optical Path Difference (OPD)-scan wavefront aberrometer. Root-mean-square (RMS) values of HOAs, total spherical aberration (TSA), total coma (TC), and total trefoil (TT) were analyzed. Correlation analysis was performed to assess the aberration symmetry between right and left eyes. The repeatability of the OPD-scan measurements was assessed by calculating Pearson r correlation coefficients between each pair of measurements and the interclass correlation coefficients between the 3 measurements of each score. The mean RMS values of HOAs, TSA, TC, and TT were 0.347 microm +/- 0.252 (SD), 0.120 +/- 0.174 microm, 0.165 +/- 0.168 microm, and 0.252 +/- 0.157 microm, respectively. The HOAs, TSA, TC, and TT changed slightly and not significantly with increasing refractive error (all P>.05). The RMS level of HOAs and TTR of the 3rd measurement was significantly different from the 1st and 2nd measurements (P<.05), with overall low correlation between the 3 measurements for the HOAs, TSA, TC, and TT. The ocular wavefront aberrations varied greatly from subject to subject. Ocular HOAs were not correlated with refractive error. The repeatability of HOAs measurements with the OPD-aberrometry was low.Keywords
This publication has 21 references indexed in Scilit:
- Temporal Changes in Optical Quality of Air–Tear Film Interface at Anterior Cornea after BlinkInvestigative Ophthalmology & Visual Science, 2004
- Test–Retest Reliability of Clinical Shack-Hartmann MeasurementsInvestigative Ophthalmology & Visual Science, 2004
- In vivo and in vitro repeatability of Hartmann-Shack aberrometryJournal of Cataract & Refractive Surgery, 2003
- Spherical aberration after laser in situ keratomileusis and photorefractive keratectomyJournal of Cataract & Refractive Surgery, 2003
- Ocular higher-order aberrations in individuals screened for refractive surgeryJournal of Cataract & Refractive Surgery, 2003
- Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-upJournal of Cataract & Refractive Surgery, 2003
- Relationship between Refractive Error and Monochromatic Aberrations of the EyeOptometry and Vision Science, 2003
- Monochromatic aberrations in the accommodated human eyeVision Research, 2000
- Monochromatic aberrations and myopiaVision Research, 1995
- Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the howland aberroscope techniqueVision Research, 1995