The importance of spatial resolution in detecting chronic myocardial iron remnants following hemorrhagic myocardial infarction with T2* MRI
- 1 July 2026
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045001
Abstract
Purpose . Intramyocardial hemorrhage following revascularized myocardial infarction is associated with increased mortality and morbidity. T2* cardiac MRI is the noninvasive imaging standard for visualizing the chronic iron deposits from hemorrhagic myocardial infarction (hMI). However, the impact of spatial resolution on detection performance of these iron deposits remains unclear. Methods . We investigated the influence of spatial resolution on the detection of iron deposits following hMI using (i) digital phantom simulations across voxel sizes (0.4–2.0 mm 2 in-plane; 2–8 mm slice thickness) at multiple Signal-to-noise ratio (SNR) levels, (ii) ex-vivo swine hearts ( n = 10) with 8 week hMI. ex-vivo imaging studies employed multi-gradient-echo sequences with various in-plane and through-plane resolutions with minimal SNR constraints ( Unconstrained Acquisitions ) and with in-vivo time constraints ( Constrained Acquisitions ), and (iii) in-vivo T2* imaging at standard spatial resolution (1.6 × 1.6 × 6 mm 3 ). Detection performance was assessed using receiver operating characteristics analysis and its area-under-the-curve (AUC), along with SNR and contrast-to-noise-ratio. Histopathology and mass spectrometry validated iron distribution. Results . Simulations demonstrated that finer voxels minimized partial volume but reduced SNR, while coarser voxels increased SNR but masked focal lesions. Optimal performance (AUC = 0.80) was identified at 1.3–1.6 mm 2 pixel size with 2–4 mm slice thickness under Constrained Acquisitions . Detection accuracy declined sharply for iron depositions that were thin in the transmural direction (μ g g −1 , p = 0.012) and correlated with the transmural width of hMI remnants ( R 2 = 0.83). Conclusion . Spatial resolution critically determines the detectability of chronic iron remnants on T2* maps. While current clinical protocols can identify larger deposits, small (<1 mm) yet proinflammatory lesions may be missed. These results highlight the need for technical improvements to enhance detection.Keywords
Funding Information
- NIH (R01-HL133407)
This publication has 50 references indexed in Scilit:
- DeepSWI : Using Deep Learning to Enhance Susceptibility Contrast on T2 *‐Weighted MRIJournal of Magnetic Resonance Imaging, 2023
- Free‐breathing, non‐ECG, simultaneous myocardial T1, T2, T2*, and fat‐fraction mapping with motion‐resolved cardiovascular MR multitaskingMagnetic Resonance in Medicine, 2022
- Myocardial T1, T2, T2*, and fat fraction quantification via low‐rank motion‐corrected cardiac MR fingerprintingMagnetic Resonance in Medicine, 2022
- Magnetic susceptibility and R2* of myocardial reperfusion injury at 3T and 7TMagnetic Resonance in Medicine, 2021
- Longitudinal assessment of tissue properties and cardiac diffusion metrics of the ex vivo porcine heart at 7 T: Impact of continuous tissue fixation using formalinNMR in Biomedicine, 2020
- Prevalence of Regional Myocardial Thinning and Relationship With Myocardial Scarring in Patients With Coronary Artery DiseaseJAMA, 2013
- Quantitative tracking of edema, hemorrhage, and microvascular obstruction in subacute myocardial infarction in a porcine model by MRIMagnetic Resonance in Medicine, 2011
- Clinical implications of microvascular obstruction and intramyocardial haemorrhage in acute myocardial infarction using cardiovascular magnetic resonance imagingEuropean Radiology, 2010
- Intramyocardial hemorrhage and microvascular obstruction after primary percutaneous coronary interventionThe International Journal of Cardiovascular Imaging, 2009
- Myocardial T measurements in iron‐overloaded thalassemia: An in vivo study to investigate optimal methods of quantificationMagnetic Resonance in Medicine, 2008