Development of a Gaussian-Based Alignment Algorithm for the Ultrahigh-Resolution Mass Spectra of Dissolved Organic Matter
- 23 January 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (5) , 2796-2803
Abstract
The alignment of ultrahigh-resolution mass spectra (UHR-MS) is critical to inspect the presence of unique and common peaks across multiple UHR-MS spectra. However, few attempts have been conducted to develop an automated alignment method. In this study, a novel automated alignment algorithm, namely, FTMSCombine, that follows a Gaussian distribution of mass errors was developed and then integrated with existing FTMSCalibrate and TRFu algorithms to establish an open-source analysis platform, namely, FTMSAnalysis, for the UHR-MS analysis of the dissolved organic matter. The developed FTMSCombine was capable of automatically aligning peaks across different UHR-MS spectra by averaging the m/z values of each peak cluster, although the alignment should be restricted to Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) spectra collected by instruments under similar conditions. The FTMSCombine exhibited an insignificant difference in the reproducibility of chemical formulae but significantly higher mass accuracy than the ICBM-OCEAN. In addition to improving the overall mass accuracy of the whole UHR-MS dataset, the FTMSCombine could effectively exclude scatters or noise peaks using an optional rule that restricts peaks (continuously) detected in at least a certain number of spectra in the UHR-MS spectra dataset. The successfully established FTMSAnalysis (freely available in the Supporting Information of this study) is of great potential in automatically analyzing UHR-MS spectra for dissolved organic matter (DOM) and will largely facilitate the elucidation of DOM chemodivesity by UHR-MS techniques including FTICR-MS.Keywords
Funding Information
- Natural Science Foundation of Hubei Province (2022CFA029)
- National Natural Science Foundation of China (42107484)
- China University of Geosciences (122-G1323522145)
This publication has 27 references indexed in Scilit:
- Extreme isomeric complexity of dissolved organic matter found across aquatic environmentsLimnology and Oceanography Letters, 2018
- Online HPLC-ESI-HRMS Method for the Analysis and Comparison of Different Dissolved Organic Matter SamplesEnvironmental Science & Technology, 2018
- Formularity: Software for Automated Formula Assignment of Natural and Other Organic Matter from Ultrahigh-Resolution Mass SpectraAnalytical Chemistry, 2017
- Iterative Method for Mass Spectra Recalibration via Empirical Estimation of the Mass Calibration Function for Fourier Transform Mass Spectrometry-Based PetroleomicsAnalytical Chemistry, 2013
- Software Lock Mass by Two-Dimensional Minimization of Peptide Mass ErrorsJournal of the American Society for Mass Spectrometry, 2011
- Parts-Per-Billion Fourier Transform Ion Cyclotron Resonance Mass Measurement Accuracy with a “Walking” Calibration EquationAnalytical Chemistry, 2011
- MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile dataBMC Bioinformatics, 2010
- A signal filtering method for improved quantification and noise discrimination in fourier transform ion cyclotron resonance mass spectrometry-based metabolomics dataJournal of the American Society for Mass Spectrometry, 2009
- A simple and efficient method for the solid‐phase extraction of dissolved organic matter (SPE‐DOM) from seawaterLimnology and Oceanography: Methods, 2008
- Fundamentals of Molecular Formula Assignment to Ultrahigh Resolution Mass Data of Natural Organic MatterAnalytical Chemistry, 2007