Iterative Method for Mass Spectra Recalibration via Empirical Estimation of the Mass Calibration Function for Fourier Transform Mass Spectrometry-Based Petroleomics
Authors:
- 3 June 2013
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (13) , 6437-6445
Abstract
We describe a mass spectra recalibration method, which enables analysis of petroleum samples with Orbitrap FTMS. In this method, the mass calibration function is estimated on the basis of mass-to-charge ratios and abundances of internal calibrants without a need for theoretical description of residual mass errors. Importantly, to maximize the estimation accuracy of the mass calibration function, an iterative approach is implemented to obtain sufficiently high number of internal calibrants covering the entire ranges of mass-to-charge ratios and abundances of interest. For petroleomic samples, the method routinely provides root-mean-square (RMS) mass accuracies at sub-ppm level and hence allows for reliable assignment of elemental compositions. Moreover, since the achieved mass accuracies are normally limited only by random errors of low-abundance analytes, the method maximizes the range of abundances of assignable species for a given signal-to-noise ratio of experimental data. Additionally, despite being initially developed for Orbitrap FTMS, the method is likewise applicable for ion cyclotron resonance FTMS.Keywords
This publication has 41 references indexed in Scilit:
- Software Lock Mass by Two-Dimensional Minimization of Peptide Mass ErrorsJournal of the American Society for Mass Spectrometry, 2011
- Petroleomics: advanced molecular probe for petroleum heavy endsJournal of Mass Spectrometry, 2011
- Sub-part-per-million Precursor and Product Mass Accuracy for High-throughput Proteomics on an Electron Transfer Dissociation-enabled Orbitrap Mass SpectrometerMolecular & Cellular Proteomics, 2010
- Elimination of Systematic Mass Measurement Errors in Liquid Chromatography−Mass Spectrometry Based Proteomics Using Regression Models and a Priori Partial Knowledge of the Sample ContentAnalytical Chemistry, 2007
- Experimental evidence for space-charge effects between ions of the same mass-to-charge in Fourier-transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry, 2007
- Parts-Per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass SpectrometerAnalytical Chemistry, 2007
- Nonparametric Mass Calibration Using Hundreds of Internal CalibrantsAnalytical Chemistry, 2007
- Statistical Evaluation of Internal and External Mass Calibration Laws Utilized in Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2005
- Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICRAnalytical Chemistry, 1998
- Experimental determination of the effects of space charge on ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983