Lateral locked plating for proximal tibial fractures with metaphyseal disruption provides a biomechanically stable and biologically favorable alternative to conventional medial/lateral plate fixation. New polyaxial screw technology incorporates expanding screw bushings, allowing variable angle screw placement, while providing angular stability. We hypothesize that polyaxial locking plates will exhibit comparable stiffness, strength to failure, and resistance to plastic deformation to conventional locking plates in a proximal tibial gap model. We stabilized extra-articular metaphyseal gap osteotomies in synthetic composite tibiae with dual medial and lateral plating, Less Invasive Stabilization System (LISS) plates, 4.5-mm proximal tibial lateral locking plates with (LP+) and without (LP-) angled screws, and 4.5-mm polyaxial locking plates with (PA+) and without (PA-) angled screws. All were tested with cyclic, ramped, and axial loading to failure. No plates demonstrated screw failure before plate failure. Dual-plate constructs did not fail. All lateral plates failed at the osteotomy. LP- failed at low load. PA+ was significantly stiffer (165 +/- 17 N/mm) with greater load to failure (711 +/- 23 N) than all other constructs (PA-: 56 +/- 6 N/mm, 617 +/- 33 N; LP+: 137 +/- 23 N/mm, 488 +/- 39 N; LISS: 76 +/- 5 N/mm, 656 +/- 39 N). PA+ had significantly less plastic deformation (12.1 +/- 0.8 mm) than LP+ (13.4 +/- 3.7 mm), but more than PA- (5.8 +/- 1.2 mm) and LISS (3.9 +/- 0.6 mm). PA- did not differ significantly from LISS in any parameter. This study demonstrates that this unique polyaxial locking plate mechanism, when tested in various constructs, exhibits similar biomechanical performance regarding stiffness, strength to failure, and resistance to plastic deformation when compared with uniaxial locking plates. The polyaxial locking plate with an angled screw was stiffest and had the greatest load to failure. The polyaxial locking plate alone tested similar to the LISS. In addition, the benefit of the angled screw for biomechanical stability is demonstrated.Keywords
This publication has 27 references indexed in Scilit:
- Biomechanical Analysis of Bicondylar Tibial Plateau Fixation: How Does Lateral Locking Plate Fixation Compare to Dual Plate Fixation?Journal of Orthopaedic Trauma, 2007
- The Effect of Plate Rotation on the Stiffness of Femoral LISS: A Mechanical StudyJournal of Orthopaedic Trauma, 2006
- Contributions of muscles, ligaments, and the ground‐reaction force to tibiofemoral joint loading during normal gaitJournal of Orthopaedic Research, 2006
- Experimental model of tibial plateau fracture for biomechanical testingJournal of Biomechanics, 2006
- Treatment of Proximal Tibia Fractures Using the Less Invasive Stabilization SystemJournal of Orthopaedic Trauma, 2004
- Less Invasive Stabilization of Complex Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2004
- Unstable Proximal Extraarticular Tibia FracturesJournal of Orthopaedic Trauma, 2004
- Bicondylar Tibial Plateau Fractures: A Biomechanical StudyClinical Orthopaedics and Related Research, 2003
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- The mechanics of the knee joint in relation to normal walkingJournal of Biomechanics, 1970