Pre-procedural CT imaging aids neonatal PDA stenting for ductal-dependent pulmonary blood flow with reduction in overall procedural morbidity
- 19 October 2021
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 32 (9) , 1401-1406
Abstract
Patent ductus arteriosus stenting for ductal-dependent pulmonary blood flow is a technically challenging neonatal procedure to maintain a stable pulmonary circulation. Pre-procedural computed tomography imaging aids in outlining ductal origin, insertion, size, course and curvature. Computed tomography imaging may add value to procedural outcomes and reduce overall procedural morbidity in neonatal patent ductus arteriosus stenting. We conducted a single centre retrospective chart review of neonates with ductal-dependent pulmonary blood flow who underwent patent ductus arteriosus stenting between January 1, 2014 and June 31, 2020. We compared patients variables between patients who underwent pre-procedural computed tomography imaging to those who did not. A total of 64 patients were referred for patent ductus arteriosus stenting with 33 (52%) obtaining pre-procedural computed tomography imaging. Average age [19 days; range 1–242 days (p = 0.85)] and weight [3.3 kg (range 2.2–6.0 kg; p = 0.19)] was not significantly different between the groups. A diagnosis of pulmonary atresia was made in 42 out of 64 (66%) patients prior to patent ductus arteriosus stenting. The cohort with pre-intervention computed tomography imaging had a significant reduction in the total number of access sites (1.2 versus 1.5; p = 0.03), contrast needed (5.9 versus 8.2 ml/kg; p = 0.008), fluoroscopy (20.7 versus 38.8 minutes; p = 0.02) and procedural time (83.4–128.4 minutes; p = 0.002) for the intervention. There was no significant difference in radiation burden between the groups (p = 0.35). Pre-procedural computed tomography imaging adds value by aiding interventional planning for neonatal patent ductus arteriosus stenting. A statistically significant reduction in the number of access sites, contrast exposure, as well as fluoroscopic and procedural time was noted without significantly increasing the cumulative radiation burden.Keywords
This publication has 14 references indexed in Scilit:
- Preprocedural three‐dimensional planning aids in transcatheter ductal stent placement: A single‐center experienceCatheterization and Cardiovascular Interventions, 2019
- Classification scheme for ductal morphology in cyanotic patients with ductal dependent pulmonary blood flow and association with outcomes of patent ductus arteriosus stentingCatheterization and Cardiovascular Interventions, 2019
- Stenting of the ductus arteriosus for ductal-dependent pulmonary blood flow-current techniques and procedural considerationsCongenital Heart Disease, 2019
- Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood FlowCirculation, 2018
- Duct Stenting Versus Modified Blalock-Taussig Shunt in Neonates With Duct-Dependent Pulmonary Blood FlowCirculation, 2018
- Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed TomographyJACC: Cardiovascular Imaging, 2018
- BODY SIZE-SPECIFIC EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR CT SCANSRadiation Protection Dosimetry, 2016
- Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length ProductRadiology, 2010
- NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE—ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS?Health Physics, 2009
- Stenting of the arterial duct: a new approach to palliation for pulmonary atresia.Heart, 1992