Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow
Authors:
Top Cited Papers
- 6 February 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 137 (6) , 589-601
Abstract
Background: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. Methods: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. Results: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P =0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P P =0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8–91.1; P P P P =0.006), and larger (152 mm 2 /m 2 [95% CI, 132–176] versus 125 mm 2 /m 2 [95% CI, 113–138]; P =0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8–0.89] versus 0.77 [95% CI, 0.75–0.8]; P =0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. Conclusions: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.Keywords
This publication has 33 references indexed in Scilit:
- Stenting of the ductus arteriosus in infants with functionally univentricular heart disease and ductal‐dependent pulmonary blood flow: A single‐center experienceCatheterization and Cardiovascular Interventions, 2016
- Percutaneous carotid artery access in infants < 3 months of ageCatheterization and Cardiovascular Interventions, 2015
- Ten‐years, single‐center experience with arterial duct stenting in duct‐dependent pulmonary circulation: Early results, learning‐curve changes, and mid‐term outcomeCatheterization and Cardiovascular Interventions, 2015
- Comparison of ductal stenting versus surgical shunts for palliation of patients with pulmonary atresia and intact ventricular septumCatheterization and Cardiovascular Interventions, 2015
- Outcomes using a clinical practice pathway for the management of pulse loss following pediatric cardiac catheterizationCatheterization and Cardiovascular Interventions, 2014
- Stenting the arterial duct in neonates and infants with congenital heart disease and duct‐dependent pulmonary blood flow: A multicenter experience of an evolving therapy over 18 yearsCatheterization and Cardiovascular Interventions, 2013
- Short-Term Result of Ductus Arteriosus Stent Implantation Compared With Surgically Created ShuntsPediatric Cardiology, 2012
- Arterial duct stenting in low‐weight newborns with duct‐dependent pulmonary circulationCatheterization and Cardiovascular Interventions, 2011
- Pulmonary artery growth following arterial duct stenting in congenital heart disease with duct‐dependent pulmonary circulationCatheterization and Cardiovascular Interventions, 2009
- Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart diseaseCatheterization and Cardiovascular Interventions, 2004