Assessment of Fetal Dose and Health Effect to the Fetus from Breast Cancer Radiotherapy during Pregnancy
Open Access
Abstract
Decision for radiotherapy during the first trimester of pregnancy may occur, as patients may not realize their pregnancy at the very early stage. Since radiation dose can affect fetal development, the aim of this study was to evaluate fetal dose and associated deterministic effects and risks to the fetus from breast cancer radiotherapy of an 8-week pregnant patient. PHITS (Particle and Heavy Ion Transport code System) Monte Carlo simulation and the J-45 computational pregnancy phantom were used to simulate breast cancer radiotherapy from a 6 MV TrueBeam linear accelerator using the three dimensional-conformal radiotherapy (3D-CRT) technique with a prescribed dose to the planning target volume (PTV) of 50 Gy. Once the fetal dose was evaluated, the occurrence of the deterministic effects and risks for developing stochastic effects in the fetus were assessed using the recommendations of NCRP Report No. 174, AAPM Report No. 50, and ICRP Publication 84. The fetal dose was evaluated to be 3.37 ± 2.66 mGy, suggesting that the fetus was expected to have no additional deterministic effects, while the risks for developing cancer and malfunctions were similar to that expected from exposure to background radiation. The comparison with the other studies showed that accurate consideration of fetal position and size was important for dose determination in the fetus, especially at the early pregnancy stage when the fetus is very small.Keywords
This publication has 20 references indexed in Scilit:
- Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon BeamJournal of Medical Signals & Sensors, 2013
- Evaluation of organ-specific peripheral doses after 2-dimensional, 3-dimensional and hybrid intensity modulated radiation therapy for breast cancer based on Monte Carlo and convolution/superposition algorithms: Implications for secondary cancer risk assessmentRadiotherapy and Oncology, 2013
- Radiotherapy for supradiaphragmatic Hodgkin’s disease: Determination of the proper fetal shielding conditions using Monte Carlo methodologyPhysica Medica, 2011
- A feasibility study to calculate unshielded fetal doses to pregnant patients in 6-MV photon treatments using Monte Carlo methods and anatomically realistic phantomsMedical Physics, 2008
- Surface dosimetry for oblique tangential photon beams: A Monte Carlo simulation studyMedical Physics, 2007
- Evaluation of the accuracy of fetal dose estimates using TG‐36 dataMedical Physics, 2007
- Radiotherapy of Hodgkin's disease in early pregnancy: embryo dose measurementsRadiotherapy and Oncology, 2003
- Fetal Dose Evaluation During Breast Cancer RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998
- Fetal dose from radiotherapy with photon beams: Report of AAPM Radiation Therapy Committee Task Group No. 36Medical Physics, 1995
- Tolerance of normal tissue to therapeutic irradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991