An Occupant-Oriented Calculation Method of Building Interior Cooling Load Design
Open Access
- 31 May 2018
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 10 (6) , 1821
Abstract
Given continued improvement in the thermal performance of building envelopes, interior disturbances caused by occupant behavior now have the greatest impact on building loads and energy consumption. The accurate calculation of interior load during design stage was emphasized in this paper, and a new method was proposed. Indoor occupants were considered as the core of interior disturbances, and the relationship with other interior disturbances was explored. The interior heat release was arbitrarily combined with the representative cooling load to be utilized in building cooling load calculation. Field surveys were conducted in three typical university buildings: an office building, a teaching building, and a library, located in a university in Tianjin, China. The oversized chillers supplying cooling for the buildings resulted from the over-estimating of the indoor occupant number and the power density of electric appliances. Through quantitative analysis, it was observed that the maximum representative interior loads were 196.43, 329.94, and 402.58 W/person, respectively, for the case buildings, at least 50% less than the empirical design data. Compared to the measured cooling load during the testing period, the accuracy of the modified cooling load was greater than 90%. This research is intended to serve as a reference for calculating and optimizing the design loads of cooling systems.Keywords
Funding Information
- National Natural Science Foundation of China (51678396)
This publication has 38 references indexed in Scilit:
- Urban Sustainability through Public ArchitectureSustainability, 2018
- Energy efficiency evaluation of key energy consumption sectors in China based on a macro-evaluating systemEnergy, 2018
- Beyond energy efficiency and individual behaviours: policy insights from social practice theoriesEnergy Policy, 2018
- Energy Performance Analysis of an Integrated Distributed Variable-Frequency Pump and Water Storage System for District Cooling SystemsApplied Sciences, 2017
- From occupancy to occupant behavior: An analytical survey of data acquisition technologies, modeling methodologies and simulation coupling mechanisms for building energy efficiencyRenewable and Sustainable Energy Reviews, 2017
- Occupant behavior modeling for building performance simulation: Current state and future challengesEnergy and Buildings, 2015
- Data and analytics to inform energy retrofit of high performance buildingsApplied Energy, 2014
- The impact of behavioural factors in the renewable energy investment decision making process: Conceptual framework and empirical findingsEnergy Policy, 2012
- Basic actions to improve energy efficiency in commercial buildings in operationEnergy and Buildings, 2011
- A study of the importance of occupancy to building cooling load in prediction by intelligent approachEnergy Conversion and Management, 2011