Huiyan Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huiyan Deng has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fan Yang
School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Neng Zhu
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
1 shared publication - Yan Ding
School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Zhaoxia Wang
School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
1 shared publication
Latest Publications
- Open Access
- 31 May 2018
- Published by MDPI AG in Sustainability
- Vol. 10 (6) , 1821
An Occupant-Oriented Calculation Method of Building Interior Cooling Load Design
Given continued improvement in the thermal performance of building envelopes, interior disturbances caused by occupant behavior now have the greatest impact on building loads and energy consumption. The accurate calculation of interior load during design stage was emphasized in this paper, and a new method was proposed. Indoor occupants were considered as the core of interior disturbances, and the relationship with other interior disturbances was explored. The interior heat release was arbitrarily combined with the representative cooling load to be utilized in building cooling load calculation. Field surveys were conducted in three typical university buildings: an office building, a teaching building, and a library, located in a university in Tianjin, China. The oversized chillers supplying cooling for the buildings resulted from the over-estimating of the indoor occupant number and the power density of electric appliances. Through quantitative analysis, it was observed that the maximum representative interior loads were 196.43, 329.94, and 402.58 W/person, respectively, for the case buildings, at least 50% less than the empirical design data. Compared to the measured cooling load during the testing period, the accuracy of the modified cooling load was greater than 90%. This research is intended to serve as a reference for calculating and optimizing the design loads of cooling systems.
- 31 May 2018
- Published by MDPI AG in Sustainability
- Vol. 10 (6) , 1821
Open AccessAn Occupant-Oriented Calculation Method of Building Interior Cooling Load Design
Given continued improvement in the thermal performance of building envelopes, interior disturbances caused by occupant behavior now have the greatest impact on building loads and energy consumption. The accurate calculation of interior load during design stage was emphasized in this paper, and a new method was proposed. Indoor occupants were considered as the core of interior disturbances, and the relationship with other interior disturbances was explored. The interior heat release was arbitrarily combined with the representative cooling load to be utilized in building cooling load calculation. Field surveys were conducted in three typical university buildings: an office building, a teaching building, and a library, located in a university in Tianjin, China. The oversized chillers supplying cooling for the buildings resulted from the over-estimating of the indoor occupant number and the power density of electric appliances. Through quantitative analysis, it was observed that the maximum representative interior loads were 196.43, 329.94, and 402.58 W/person, respectively, for the case buildings, at least 50% less than the empirical design data. Compared to the measured cooling load during the testing period, the accuracy of the modified cooling load was greater than 90%. This research is intended to serve as a reference for calculating and optimizing the design loads of cooling systems.