Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging
Authors:
Open Access
- 1 November 2015
- journal article
- review article
- Published by Taylor & Francis in Research and Reports in Nuclear Medicine
- Vol. 5, 19-32
Abstract
Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging Iman Daryaei,1 Mark D Pagel1–4 1Department of Chemistry and Biochemistry, 2Department of Biomedical Engineering, 3Department of Medical Imaging, University of Arizona, 4The University of Arizona Cancer Center, Tucson, AZ, USA Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T2-exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T1 and T2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging. Keywords: CEST, T2ex, T2 relaxation, responsive agents, exchange rateKeywords
This publication has 77 references indexed in Scilit:
- Tuning Phenols with Intra‐Molecular Bond Shifted HYdrogens (IM‐SHY) as diaCEST MRI Contrast AgentsChemistry – A European Journal, 2014
- Detection of in vivo enzyme activity with CatalyCEST MRIMagnetic Resonance in Medicine, 2013
- A CatalyCEST MRI Contrast Agent That Detects the Enzyme-Catalyzed Creation of a Covalent BondJournal of the American Chemical Society, 2013
- Monitoring Enzyme Activity Using a Diamagnetic Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast AgentJournal of the American Chemical Society, 2011
- A self‐calibrating PARACEST MRI contrast agent that detects esterase enzyme activityContrast Media & Molecular Imaging, 2010
- A paramagnetic chemical exchange-based MRI probe metabolized by cathepsin D: design, synthesis and cellular uptake studiesOrganic & Biomolecular Chemistry, 2010
- Using Two Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Contrast Agents for Molecular Imaging StudiesAccounts of Chemical Research, 2009
- Detection of Enzymatic Activity by PARACEST MRI: A General Approach to Target a Large Variety of EnzymesAngewandte Chemie International Edition, 2008
- A PARACEST MRI Contrast Agent To Detect Enzyme ActivityJournal of the American Chemical Society, 2006
- Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST)Magnetic Resonance in Medicine, 2000