Research and Reports in Nuclear Medicine

Published by Taylor & Francis

Abbrev: Res. Rep. Nucl. Med.
EISSN 2230-228X
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
13
2025 journal articles
0

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Breast Cancer
1
Oncology
1

Top Countries

Publications in 2016-2026.

CountryPublications
Netherlands
1
Spain
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
0
Total Publications
0
Average Citations
0.00
Cited Publications
0
Cited Publications %
0%
Self Citations
0
Self Citations %
0%

Metrics
h5_index
0
Monthly Citation Metric (MCM)
0

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
0
Max
0

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Using lymphoscintigraphy as a prognostic tool in patients with cancer

    by Sergi Vidal-Sicart, Renato A Valdés Olmos

    Early detection of metastatic involvement of lymph nodes is one of the greatest difficulties faced by the physicians. In the last few centuries, the lymphatic system has become an important field of interest in oncology. The lymphatic system functions in two opposing ways in cancer: defense against circulating tumor cells, and, on the other hand, a route for metastasis and a site of tumor growth when the defense mechanism fails. The significant impact of lymphatic dissemination on the staging, treatment, and outcome of solid cancers has stimulated investigations aimed at gaining more insight into several aspects of the lymphatic system. Its application in oncology has evolved in the last 50 years fostered by the recognition of the relationship of lymph node metastases to prognosis in several types of malignant tumors. Lymphatic mapping also offers the opportunity for repetitive studies undertaken for evaluation of the patient during follow-up, thereby offering early evidence of recurrence of the disease. More recent and widespread applications of lymphoscintigraphy form the basis for biopsy of the sentinel lymph node in patients with solid cancers. This article reviews the applications of lymphoscintigraphy in the current diverse oncologic clinical indications for the assessment of secondary lymphedema related to oncologic treatments and sentinel lymph node lymphatic mapping.


  • Open Access

    Clinical utility of gadobenate dimeglumine in contrast-enhanced MRI of the breast: a review

    by Maria Laura Luciani, Marianna Telesca, Miles Kirchin, Federica Pediconi

    Clinical utility of gadobenate dimeglumine in contrast-enhanced MRI of the breast: a review Maria Laura Luciani,1 Marianna Telesca,1 Miles A Kirchin,2 Federica Pediconi1 1Department of Radiological Sciences, Oncology and Anatomic Pathology, Sapienza University of Rome, Rome, Italy; 2Global Medical & Regulatory Affairs, Bracco Imaging SpA, Milan, Italy Breast magnetic resonance imaging (MRI) is considered the technique with the highest sensitivity for breast cancer detection. Gadobenate dimeglumine is a gadolinium-based contrast agent (GBCA) that is specifically approved in Europe for breast MRI and which has the highest r1 relaxivity among all GBCAs for this indication. In order to improve the diagnostic performance of breast MRI, several intra-individual crossover studies have evaluated gadobenate dimeglumine as a possible GBCA for this application. This review focuses on the role and advantages of gadobenate dimeglumine as a contrast agent for breast MRI by describing the unique properties of this agent and by summarizing published studies. Keywords: magnetic resonance, breast imaging, oncology, breast, tumor, women's imaging


  • Open Access

    Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging

    by Mark D Pagel, Iman Daryaei

    Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging Iman Daryaei,1 Mark D Pagel1–4 1Department of Chemistry and Biochemistry, 2Department of Biomedical Engineering, 3Department of Medical Imaging, University of Arizona, 4The University of Arizona Cancer Center, Tucson, AZ, USA Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T2-exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T1 and T2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging. Keywords: CEST, T2ex, T2 relaxation, responsive agents, exchange rate


  • Open Access

    Scintigraphic parathyroid imaging: concepts and new developments

    by Abdelhamid H Elgazzar, Saud Alenezi, Saker Asa'AD

    Hyperparathyroidism is a condition caused by increased secretion of the parathyroid hormone, which plays an important role in calcium homeostasis. This condition has been diagnosed more frequently recently and can affect multiple organ systems resulting in a variety of signs and symptoms. Hyperparathyroidism can be classified as primary, secondary, or tertiary disease and can result from eutopic or ectopic parathyroid lesions. Parathyroid adenoma is the most common cause of primary hyperparathyroidism, accounting for more than 80% of cases. Parathyroid hyperplasia is the cause in about 20% of patients, while parathyroid carcinoma is rare and accounts for less than 1% of cases. Surgical removal of the abnormal gland(s) is the definite treatment for hyperparathyroidism. Bilateral neck exploration is the classical approach for parathyroidectomy. In recent years, minimally invasive parathyroidectomy is becoming more popular due to the fewer complications and shorter hospital stay. This new approach has placed a greater emphasis on the preoperative localization techniques. Multiple localization techniques have been used, including invasive techniques, anatomical, and scintigraphic imaging modalities. Thallium/pertechnetate subtraction method was introduced in 1980 and was the first method to gain widespread acceptance. It is not widely used now due to the suboptimal characteristics of thallium and the technical difficulties associated with subtraction and registration. The dual-phase method using Tc-99m sestamibi is currently the method of choice for parathyroid localization. It is based on the differential washout rate of sestamibi from the thyroid and abnormal parathyroid glands. The reported sensitivity of this method ranges from 80% to 90%. The addition of single-photon emission computed tomography (SPECT) and more recently SPECT/CT improves the anatomical localization and helps in the differentiation of the parathyroid from the thyroid lesions. Multiple factors can affect the sensitivity of the scan including the lesion size, cellularity, and the presence of P-glycoprotein. Modification of the imaging protocol may help to avoid false positive or false negative results in certain cases. Positron emission tomography has been recently investigated for possible role in parathyroid imaging and showed promising results with 11C-methionine.


  • Open Access

    Standardization of dual time point [18F] 2-Deoxy-2-fluoro-D-glucose-positron emission tomography performed with different positron emission tomography scanners using partial volume correction

    by Shohei Mikasa, Go Akamatsu, Takafumi Taniguchi, Daisuke Kidera, Ken Kihara, Kohki Matsuoka, Shinji Amakusa, Tsuyoshi Yoshida, Masayuki Sasaki

    Standardization of dual time point [18F] 2-Deoxy-2-fluoro-D-glucose-positron emission tomography performed with different positron emission tomography scanners using partial volume correction Shohei Mikasa,1 Go Akamatsu,1 Takafumi Taniguchi,1 Daisuke Kidera,1 Ken Kihara,1 Kohki Matsuoka,2 Shinji Amakusa,2 Tsuyoshi Yoshida,2 Masayuki Sasaki1 1Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan; 2PET Imaging Center, Koga Hospital 21, Kurume, Japan Introduction: The aim of this study was to examine the possibility of using the partial volume correction (PVC) to standardize dual time point [18F] 2-Deoxy-2-fluoro-D-glucose (FDG)-positron emission tomography (PET) studies with two PET scanners. Materials and methods: One hundred and thirteen lesions from 96 breast cancer patients were examined. FDG-PET scans were performed at both 60 and 120 minutes after FDG injection using different PET scanners. The maximum standardized uptake values (SUVmaxs) were measured at both time points (SUVmax1 and SUVmax2) and the percent change in the SUVmax (∆%SUVmax) between the two time points was calculated. PVC was performed using a look-up table generated based on the recovery coefficient curves and point spread function of each scanner. Results: The SUVmax1, the SUVmax2, and the ∆%SUVmax were 5.67±4.45, 5.15±4.29, and -9.30%±20.54%, respectively. After PVC, all parameters significantly increased to 10.44±5.55, 10.23±5.77, and -1.15%±21.66%, respectively. In addition, the number of lesions with a positive ∆%SUVmax increased after PVC, from 26.5% to 40.7%. Conclusion: PVC of the SUVmax is considered to be useful for standardizing dual time point FDG-PET studies in patients with breast cancer performed using different PET scanners. This method is also expected to be useful for standardizing multicenter PET studies. Keywords: FDG-PET, SUV, standardization, partial volume correction, breast cancer, dual time point imaging


  • Open Access

    Evaluation of active and passive shimming in magnetic resonance imaging

    by Keith Wachowicz

    Evaluation of active and passive shimming in magnetic resonance imaging Keith Wachowicz Division of Medical Physics, Department of Oncology, University of Alberta, Edmonton, AB, Canada With higher magnet strengths for magnetic resonance imaging (MRI) units becoming more commonplace, both for animal imaging systems as well as whole-body in vivo systems, magnetic field distortions due to inhomogeneous distributions of magnetic susceptibility and air–tissue interfaces will become more intense. Further, the popularization of MRI-hybrid devices, such as positron emission tomography/MR or MR/radiotherapy hybrids, which rely on the assumption of geometric accuracy for their diagnostic or therapeutic effectiveness, will lead to greater restrictions on permissible geometric error. As a result, shimming procedures (methods by which the distortions induced on the main magnetic field, B0, are remedied) are requiring greater flexibility and corrective range. Shimming methods can be broadly classified into passive (using materials with magnetic properties to remedy field distortions through their passive response to B0) and active techniques (utilizing strategically placed and energized electric coils to produce corrective magnetic fields). Both these techniques have promise to address the additional challenges brought about by the changing MRI landscape. This work reviews traditional shimming methods and principles, and gives an overview of new and novel approaches to this ever-important issue in MRI. Keywords: MRI, shim, passive, active, high-order


  • Open Access

    PET imaging using radiolabelled antibodies: future direction in tumor diagnosis and correlate applications

    by Giorgio Treglia, Marco Salsano

    Immuno-positron emission tomography (PET) is a new imaging tool that finds application in diagnostic as well as in prognostic and therapeutic oncology. Monoclonal antibodies (mAbs) present the unique ability to selectively bind specific antigens produced by tumors, establishing the presence, location, and number of neoplastic foci. They are produced in unlimited quantities with absolute specificity using the hybridoma method. Treatment with mAbs can have different forms: they can be administered alone or can be combined with a radioactive molecule, which then delivers the radiation directly to the tumor cells. In immuno-PET, mAbs are labeled with various radionuclides and used in cancer patients who produce tumor-associated antigens. In this review we will discuss immuno-PET applications in tumor diseases, focusing on the technique, mAbs, positron emitter selection, and on its future applications.


  • Open Access

    Hilson index and renal transplant rejection: a single-center experience

    by Muhammad Choudhry, Rao

    Background: The Hilson index has been used in addition to sequential images and changes in posttransplant region-of-interest curves to separate rejections from acute tubular necrosis. The aim of the present retrospective study was to evaluate the role of the Hilson index in accurately diagnosing renal transplant rejection and to explore the correlation between changes in the perfusion index across serial scans with the incidence of rejection. Methods: Using the Hilson index, we retrospectively examined 150 renal biopsies and 250 perfusion scans from 150 renal transplant recipients from 2010 to 2012 at our center. A Hilson index above 150 was labeled as positive and anything less as negative. Renal transplant rejection was diagnosed by correlating clinical suspicion with the histological findings of the renal biopsy. The Hilson index closest to the perfusion scan and the histology findings on renal biopsy were used to calculate the sensitivity and specificity of the index in diagnosing renal transplant rejection. Logistical regression was used to determine the relationship between absolute and percentage changes in perfusion scan indices with histological findings. Results: The Hilson index had a sensitivity of 26% and a specificity of 82% in predicting renal transplant rejection. The Hilson index was not specific in differentiating between acute tubular necrosis and renal rejection. The absolute and percentage changes in value of the index did not correlate with renal transplant rejection. Conclusion: At our center, the Hilson index had poor sensitivity for diagnosing renal transplant rejection. The absolute and percentage changes in the Hilson index across serial scans failed to correlate with renal transplant rejection. The findings of this audit suggest the need for individual clinical discretion and the use of the Hilson index as supportive information only. This has raised interest in utilizing resistive indices from renal ultrasound for this purpose at our center. The sensitivity and specificity of Doppler ultrasound have been inconsistent and observer-dependent in various studies. Magnetic resonance imaging has been proposed but is unrealistic. Due to the nature of the test and its results, an audit cycle was not considered plausible.

  • Open Access

    Technetium-99m ethylene cysteine dimer posterior fossa perfusion and brain death

    by Usha Joseph, Kothari, Skolkin, David Wan, Isis Gayed

    Background: The purpose of this study was to evaluate the frequency of and outcome in patients with isolated posterior fossa uptake on cerebral perfusion scan. Methods: A retrospective review was undertaken of electronic medical records over 6 years from 713 consecutive patients undergoing technetium-99m ethyl cysteine dimer cerebral perfusion scans to identify isolated posterior fossa activity. Results: Of the 13 patients with isolated posterior fossa activity, 10 deteriorated to death and three had life support withdrawn. They survived an average of 0.24 day ± 0.27 standard deviation (SD) days after scanning and an average of 1.03 ± 0.33 SD days on life support. Conclusion: Unilateral or bilateral isolated posterior fossa technetium-99m ethyl cysteine dimer activity indicates imminent or impending brain death and a poor prognosis.

  • Open Access

    Impact of bone SPECT-CT imaging on evaluation of lower extremities' abnormalities

    by Isis Gayed

    Aim: This study aims to investigate the value of single photon emission computed tomography-computed tomography (SPECT-CT) imaging as part of bone scans for evaluation of a variety of pathologies of the lower extremities. Methods: The study included patients who had undergone SPECT-CT imaging as part of a bone scan between February, 2008 and May, 2009. Patients who had multiple bony metastases were excluded. Two expert readers, informed only of the site of pain, independently interpreted planar images, planar plus SPECT images, and Planar plus SPECT-CT images. The interpretations were graded as: Not certain of etiology (NS), Somewhat certain (SC), and Certain (C). Changes or additions to diagnosis and/or location of pathology were graded as (D). Results: A total of 35 consecutive patients were included, 19 females and 16 males, with an average age of 44 years. There was agreement between the two readers on the site of pathology in 32 out of 35 patients. The degree of certainty for both readers increased significantly with the addition of SPECT-CT. The certainty of diagnosis increased from 26%, using planar images alone, to 44%, with the addition of SPECT, to 74%, with the addition of SPECT-CT, for Reader 1, and from 40%, to 54%, to 69%, respectively, for Reader 2. SPECT alone added six (17%) new sites of pathology to those identified from planar images, changed the diagnosis for one patient, and added a diagnosis for one other (6%). SPECT-CT changed the diagnosis for three patients, and added another diagnosis for one more patient (11%). Conclusion: SPECT-CT increased the certainty of location and diagnosis of bony pathology in the lower extremity by at least 30% across a wide variety of abnormalities.