Determination of Trace Bismuth in Environmental Waters by ICP‐MS with Cobalt Ion‐Assisted Photochemical Vapour Generation
- 6 March 2020
- journal article
- research article
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 44 (3) , 617-627
Abstract
With increasing use of bismuth in industry, a better understanding of its environmental behaviour is required, including an improved knowledge of its background concentration range in (non‐saline) freshwaters. However, the poor analytical sensitivity of previous methods may lead to inaccurate measurement results for Bi3+ in environmental samples. In this work, cobalt ion‐assisted photochemical vapour generation (PVG) was developed for the detection of trace Bi with inductively coupled plasma‐mass spectrometry (ICP‐MS) measurement. The volatile species of Bi was found to be (CH3)3Bi generated under UV irradiation in the presence of formic acid, acetic acid and Co2+. The major parameters potentially influencing the detection of Bi were investigated. Under optimised conditions, the limit of detection (3s, n = 11) of the proposed method was 0.3 ng l−1. The analytical sensitivity was enhanced about 70‐fold for Bi3+ compared with that using classic pneumatic nebulisation of ICP‐MS. Furthermore, the proposed method showed better analytical sensitivity and anti‐interference ability towards co‐existing ions compared with ferric ion‐assisted PVG systems. The accuracy of the proposed method was evaluated by analysis of environmental water samples and certified reference materials with satisfactory results.Keywords
Funding Information
- National Natural Science Foundation of China (41973019)
- China Postdoctoral Science Foundation (2016M590870, 2018T110952)
- Education Department of Sichuan Province (17ZA0040)
This publication has 53 references indexed in Scilit:
- Photochemical Vapor Generation for Colorimetric Speciation of Inorganic SeleniumAnalytical Chemistry, 2019
- An on-line system using ion-imprinted polymer for preconcentration and determination of bismuth in seawater employing atomic fluorescence spectrometryTalanta, 2018
- Determination of Ga, Ge, Mo, Ag, Cd, In, Sn, Sb, W, Tl and Bi in USGS Whole‐Rock Reference Materials by Standard Addition ICP‐MSGeostandards and Geoanalytical Research, 2015
- Determination of antimony, bismuth and tin in natural waters by flow injection solid phase extraction coupled with online hydride generation inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2012
- How reliable are environmental data on ‘orphan’ elements? The case of bismuth concentrations in surface watersJournal of Environmental Monitoring, 2009
- Generation of volatile cobalt species by UV photoreduction and their tentative identificationJournal of Analytical Atomic Spectrometry, 2008
- Mechanism of Generation of Volatile Hydrides of Trace Elements by Aqueous Tetrahydroborate(III). Mass Spectrometric Studies on Reaction Products and IntermediatesAnalytical Chemistry, 2007
- Flow injection determination of bismuth in urine by successive retention of Bi(III) and tetrahydroborate(III) on an anion-exchange resin and hydride generation atomic absorption spectrometryTalanta, 2004
- Methylated bismuth in the environmentApplied Organometallic Chemistry, 1999
- Complementary use of capillary gas chromatography–mass spectrometry (ion trap) and gas chromatography–inductively coupled plasma mass spectrometry for the speciation of volatile antimony, tin and bismuth compounds in landfill and fermentation gases†The Analyst, 1998