To appraise the robustness of VMAT dose distributions against uncertainties in the positioning of the patients when single fraction SABRT treatments are planned. A set of 18 patients (8 lung, 5 brain, 5 spinal or para-spinal) treated with VMAT in a single fraction of 24Gy were retrospectively analyzed. All approved plans were re-calculated by applying shifts to the isocentre of ±0.5, ±1, ±1.5, ±2 and ±3 mm along the primary X, Y and Z axes. Dose calculations were performed with the AAA and the Acuros engines. Quantitative analysis of DVH was performed on a total of 36 references (18 patients with AAA, 18 with Acuros) and 1080 re-calculated plans to measure the potential degree of deterioration of the plans according to the simulated errors. The dose to the CTV was essentially not affected by the isocenter shifts in all cases. Concerning PTV, The main impact was observed on the near-to-minimum dose D99%. No relevant impact was observed on organs at risk in the case of lung patients. In the case of patients treated in the spinal or para-spinal region, the near-to-maximum dose to the spine showed, in the worst scenario, referring to Acuros calculation, a potential average increase of 0.3Gy with a maximum of 1.9Gy (from 10.3 to 12.2 Gy) or 18%. This was partially mitigated to 12% with 1 mm and to 5% with 0.5 mm shifts. The study showed that shifts in the position of the isocenter as large as 3 mm tend to have modest impacts on the quality of the VMAT plans, scored by means of conventional DVH parameters. From the data shown, the VMAT approach should be considered adequately robust for single fraction SABR.Keywords
This publication has 26 references indexed in Scilit:
- Experimentally studied dynamic dose interplay does not meaningfully affect target dose in VMAT SBRT lung treatmentsMedical Physics, 2013
- Volume Modulated Arc Therapy (VMAT) for pulmonary Stereotactic Body Radiotherapy (SBRT) in patients with lesions in close approximation to the chest wallFrontiers in Oncology, 2013
- The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targetsMedical Dosimetry, 2012
- Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Critical Appraisal of Acuros XB and Anisotropic Analytic Algorithm Dose Calculation in Advanced Non-Small-Cell Lung Cancer TreatmentsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Fast Arc Delivery for Stereotactic Body Radiotherapy of Vertebral and Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dosimetric Impact of Interplay Effect on RapidArc Lung Stereotactic Treatment DeliveryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Re-irradiation of metastatic spinal cord compression: A feasibility study by volumetric-modulated arc radiotherapy for in-field recurrence creating a dosimetric hole on the central canalRadiotherapy and Oncology, 2010
- KRAS and BRAF mutations in patients with rectal cancer treated with preoperative chemoradiotherapyRadiotherapy and Oncology, 2010
- Robust treatment planning for intensity modulated radiotherapy of prostate cancer based on coverage probabilitiesRadiotherapy and Oncology, 2006